Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation
This paper describes a simple, inexpensive, highly sensitive, and efficient electrochemical method to determine Estradiol in pharmaceutical formulations. The oxidation reaction on the electrode surface was electrochemically characterized by cyclic voltammetry (CV) and square wave voltammetry (SWV)....
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Federal de Mato Grosso do Sul
2019-09-01
|
Series: | Orbital: The Electronic Journal of Chemistry |
Subjects: | |
Online Access: | https://periodicos.ufms.br/index.php/orbital/article/view/15924 |
_version_ | 1797946818812706816 |
---|---|
author | Thais Silva Alves Antonio Rogério Fiorucci Gilberto José Arruda |
author_facet | Thais Silva Alves Antonio Rogério Fiorucci Gilberto José Arruda |
author_sort | Thais Silva Alves |
collection | DOAJ |
description |
This paper describes a simple, inexpensive, highly sensitive, and efficient electrochemical method to determine Estradiol in pharmaceutical formulations. The oxidation reaction on the electrode surface was electrochemically characterized by cyclic voltammetry (CV) and square wave voltammetry (SWV). The investigation of Estradiol at carbon paste electrode revealed a non-reversible oxidation peak at +640 mV vs. Ag/AgCl, which was used for electrochemical detection of Estradiol. The operating parameters (pH, frequency, step potential, and amplitude) were optimized in relation to the peak current intensity, and a calibration curve was set up in a concentration range of 0.059 - 2.997 mg L-1, with a detection limit of 21.85 µg L-1. After calibration curve was plotted, the developed procedure was applied to determine Estradiol in parmacheutical formulation. These results show that the proposed method can be used for Estradiol quantification in pharmaceutical formulations with high sensitivity, specificity, stability, and reproducibility, and can be applied in analytical routines in laboratories of quality control analysis in drugs.
DOI: http://dx.doi.org/10.17807/orbital.v11i4.1332
|
first_indexed | 2024-04-10T21:17:04Z |
format | Article |
id | doaj.art-0a63c1ece9e1496d9ac8416b64753327 |
institution | Directory Open Access Journal |
issn | 1984-6428 |
language | English |
last_indexed | 2024-04-10T21:17:04Z |
publishDate | 2019-09-01 |
publisher | Universidade Federal de Mato Grosso do Sul |
record_format | Article |
series | Orbital: The Electronic Journal of Chemistry |
spelling | doaj.art-0a63c1ece9e1496d9ac8416b647533272023-01-20T10:51:59ZengUniversidade Federal de Mato Grosso do SulOrbital: The Electronic Journal of Chemistry1984-64282019-09-01114Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical FormulationThais Silva Alves0Antonio Rogério Fiorucci1Gilberto José Arruda2Universidade Estadual de Mato Grosso do SulUniversidade Estadual de Mato Grosso do SulUniversidade Estadual de Mato Grosso do Sul This paper describes a simple, inexpensive, highly sensitive, and efficient electrochemical method to determine Estradiol in pharmaceutical formulations. The oxidation reaction on the electrode surface was electrochemically characterized by cyclic voltammetry (CV) and square wave voltammetry (SWV). The investigation of Estradiol at carbon paste electrode revealed a non-reversible oxidation peak at +640 mV vs. Ag/AgCl, which was used for electrochemical detection of Estradiol. The operating parameters (pH, frequency, step potential, and amplitude) were optimized in relation to the peak current intensity, and a calibration curve was set up in a concentration range of 0.059 - 2.997 mg L-1, with a detection limit of 21.85 µg L-1. After calibration curve was plotted, the developed procedure was applied to determine Estradiol in parmacheutical formulation. These results show that the proposed method can be used for Estradiol quantification in pharmaceutical formulations with high sensitivity, specificity, stability, and reproducibility, and can be applied in analytical routines in laboratories of quality control analysis in drugs. DOI: http://dx.doi.org/10.17807/orbital.v11i4.1332 https://periodicos.ufms.br/index.php/orbital/article/view/15924voltammetrycarbon paste electrodehormonesmedicationsdetermination |
spellingShingle | Thais Silva Alves Antonio Rogério Fiorucci Gilberto José Arruda Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation Orbital: The Electronic Journal of Chemistry voltammetry carbon paste electrode hormones medications determination |
title | Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation |
title_full | Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation |
title_fullStr | Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation |
title_full_unstemmed | Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation |
title_short | Development of an Electrochemical Methodology for the Quantification of β-estradiol in Pharmaceutical Formulation |
title_sort | development of an electrochemical methodology for the quantification of β estradiol in pharmaceutical formulation |
topic | voltammetry carbon paste electrode hormones medications determination |
url | https://periodicos.ufms.br/index.php/orbital/article/view/15924 |
work_keys_str_mv | AT thaissilvaalves developmentofanelectrochemicalmethodologyforthequantificationofbestradiolinpharmaceuticalformulation AT antoniorogeriofiorucci developmentofanelectrochemicalmethodologyforthequantificationofbestradiolinpharmaceuticalformulation AT gilbertojosearruda developmentofanelectrochemicalmethodologyforthequantificationofbestradiolinpharmaceuticalformulation |