Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System

The lateral imaging characteristic of an acoustic lens is similar to the well-known object-image relationship of an optical lens. In this paper, axial signal analysis is carried on and reconstruction methods for a sample's axial photoacoustic (PA) image are researched based on the acoustic-lens...

Full description

Bibliographic Details
Main Authors: Yu Zhang, Zhilie Tang, Yongbo Wu, F. D. Jiantong Zhang
Format: Article
Language:English
Published: IEEE 2017-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/7600412/
_version_ 1818616762830159872
author Yu Zhang
Zhilie Tang
Yongbo Wu
F. D. Jiantong Zhang
author_facet Yu Zhang
Zhilie Tang
Yongbo Wu
F. D. Jiantong Zhang
author_sort Yu Zhang
collection DOAJ
description The lateral imaging characteristic of an acoustic lens is similar to the well-known object-image relationship of an optical lens. In this paper, axial signal analysis is carried on and reconstruction methods for a sample's axial photoacoustic (PA) image are researched based on the acoustic-lens PA imaging system. The integral and envelope methods are both proposed to reconstruct a sample's axial PA image, which has only been achieved approximately by the PA signals' peak values obtained by a peak-holding circuit in previous reports. And the envelope method is proposed for the first time. Hilbert transform was used to obtain the envelope of the sample's PA signals and axial PA images. Simulation results show that the integral method is appropriate for low frequency samples, and that the envelope reconstruction method can provide low frequency information of the PA images of samples. So for a sample, it would be best to combine the two methods together.
first_indexed 2024-12-16T16:54:58Z
format Article
id doaj.art-0a682feae20d4deeb4ba69b9831ce19c
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-12-16T16:54:58Z
publishDate 2017-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-0a682feae20d4deeb4ba69b9831ce19c2022-12-21T22:23:54ZengIEEEIEEE Access2169-35362017-01-01591892310.1109/ACCESS.2016.26193597600412Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging SystemYu Zhang0https://orcid.org/0000-0002-6899-9258Zhilie Tang1Yongbo Wu2F. D. Jiantong Zhang3South China Normal University, Guangzhou, ChinaSouth China Normal University, Guangzhou, ChinaSouth China Normal University, Guangzhou, ChinaChina Transportation Telecommunications and Information Center, Beijing, ChinaThe lateral imaging characteristic of an acoustic lens is similar to the well-known object-image relationship of an optical lens. In this paper, axial signal analysis is carried on and reconstruction methods for a sample's axial photoacoustic (PA) image are researched based on the acoustic-lens PA imaging system. The integral and envelope methods are both proposed to reconstruct a sample's axial PA image, which has only been achieved approximately by the PA signals' peak values obtained by a peak-holding circuit in previous reports. And the envelope method is proposed for the first time. Hilbert transform was used to obtain the envelope of the sample's PA signals and axial PA images. Simulation results show that the integral method is appropriate for low frequency samples, and that the envelope reconstruction method can provide low frequency information of the PA images of samples. So for a sample, it would be best to combine the two methods together.https://ieeexplore.ieee.org/document/7600412/Signal analysisphotoacoustic effectsimage reconstructionbiomedical imagingacoustic lensaxial direction
spellingShingle Yu Zhang
Zhilie Tang
Yongbo Wu
F. D. Jiantong Zhang
Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System
IEEE Access
Signal analysis
photoacoustic effects
image reconstruction
biomedical imaging
acoustic lens
axial direction
title Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System
title_full Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System
title_fullStr Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System
title_full_unstemmed Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System
title_short Axial Signal Analysis and Image Reconstruction in Acoustic Lens Photoacoustic Imaging System
title_sort axial signal analysis and image reconstruction in acoustic lens photoacoustic imaging system
topic Signal analysis
photoacoustic effects
image reconstruction
biomedical imaging
acoustic lens
axial direction
url https://ieeexplore.ieee.org/document/7600412/
work_keys_str_mv AT yuzhang axialsignalanalysisandimagereconstructioninacousticlensphotoacousticimagingsystem
AT zhilietang axialsignalanalysisandimagereconstructioninacousticlensphotoacousticimagingsystem
AT yongbowu axialsignalanalysisandimagereconstructioninacousticlensphotoacousticimagingsystem
AT fdjiantongzhang axialsignalanalysisandimagereconstructioninacousticlensphotoacousticimagingsystem