HPLC method development and validation for the estimation of axitinibe in rabbit plasma

ABSTRACT A rapid, sensitive, and accurate high performance liquid chromatography for the determination of axitinibe (AN) in rabbit plasma is developed using crizotinibe as an internal standard (IS). Axitinibe is a tyrosine kinase inhibitor, used in the treatment of advanced kidney cancer, which work...

Full description

Bibliographic Details
Main Authors: Achanta Suneetha, Sharmila Donepudi
Format: Article
Language:English
Published: Universidade de São Paulo 2017-10-01
Series:Brazilian Journal of Pharmaceutical Sciences
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502017000300607&lng=en&tlng=en
Description
Summary:ABSTRACT A rapid, sensitive, and accurate high performance liquid chromatography for the determination of axitinibe (AN) in rabbit plasma is developed using crizotinibe as an internal standard (IS). Axitinibe is a tyrosine kinase inhibitor, used in the treatment of advanced kidney cancer, which works by slowing or stopping the growth of cancer cells. The chromatographic separation was performed on a Waters 2695, Kromosil (150 mm × 4.6 mm, 5 µm) column using a mobile phase containing buffer (pH 4.6) and acetonitrile in the ratio of 65:35 v/v with a flow rate of1 mL/min. The analyte and internal standard were extracted using liquid-liquid extraction with acetonitrile. The elution was detected by photo diode array detector at 320 nm.The total chromatographic runtime is 10.0 min with a retention time for axitinibe and IS of 5.685, and 3.606 min, respectively. The method was validated over a dynamic linear range of 0.002-0.2µg/mL for axitinibe with a correlation coefficient of r2 0.999.
ISSN:2175-9790