Influence of magnetic saturation effects on the fault detection of induction motors

In this paper, the influence of impact damage to the induction motors on the zero-sequence voltage and its spectrum is presented. The signals detecting the damages result from a detailed analysis of the formula describing this voltage component which is induced in the stator windings due to core mag...

Full description

Bibliographic Details
Main Authors: Drozdowski Piotr, Duda Arkadiusz
Format: Article
Language:English
Published: Polish Academy of Sciences 2014-09-01
Series:Archives of Electrical Engineering
Subjects:
Online Access:http://www.degruyter.com/view/j/aee.2014.63.issue-3/aee-2014-0035/aee-2014-0035.xml?format=INT
Description
Summary:In this paper, the influence of impact damage to the induction motors on the zero-sequence voltage and its spectrum is presented. The signals detecting the damages result from a detailed analysis of the formula describing this voltage component which is induced in the stator windings due to core magnetic saturation and the discrete displacement of windings. Its course is affected by the operation of both the stator and the rotor. Other fault detection methods, are known and widely applied by analysing the spectrum of stator currents. The presented method may be a complement to other methods because of the ease of measurements of the zero voltage for star connected motors. Additionally, for converter fed motors the zero sequence voltage eliminates higher time harmonics displaced by 120 degrees. The results of the method application are presented through measurements and explained by the use of a mathematical model of the slip-ring induction motor