Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite
Proper design of the building component, which not only meets the legal requirements, but also provides comfort of using of buildings, requires knowledge of the materials and solutions. Since moisture is one of the main factors that can affect the building structure destruction, it is particularly i...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Lublin University of Technology
2017-07-01
|
Series: | Budownictwo i Architektura |
Subjects: | |
Online Access: | http://bud-arch.pollub.pl/wp-content/uploads/Bud-arch_162_2017_141-151_Alberska_Brzyski.pdf |
_version_ | 1797281032935833600 |
---|---|
author | Anna Alberska Przemysław Brzyski |
author_facet | Anna Alberska Przemysław Brzyski |
author_sort | Anna Alberska |
collection | DOAJ |
description | Proper design of the building component, which not only meets the legal requirements, but also provides comfort of using of buildings, requires knowledge of the materials and solutions. Since moisture is one of the main factors that can affect the building structure destruction, it is particularly important to be aware of hygrothermal properties of components. And this is the focus of the study. In this paper several variants of external walls were analysed, according to the requirements in terms of: heat transfer coefficient U, the risk of surface and interstitial condensation. Partitions were designed with composite based on shives from industrial hemp and lime binder, which is not yet widely used in Poland. The purpose of the analysis of this material was to prove the validity of using the natural materials in residential buildings. |
first_indexed | 2024-03-07T16:50:43Z |
format | Article |
id | doaj.art-0a6f6ee5d9df4c1bbc5fde93e1ac1614 |
institution | Directory Open Access Journal |
issn | 1899-0665 2544-3275 |
language | English |
last_indexed | 2024-03-07T16:50:43Z |
publishDate | 2017-07-01 |
publisher | Lublin University of Technology |
record_format | Article |
series | Budownictwo i Architektura |
spelling | doaj.art-0a6f6ee5d9df4c1bbc5fde93e1ac16142024-03-03T05:18:30ZengLublin University of TechnologyBudownictwo i Architektura1899-06652544-32752017-07-0116214115110.24358/Bud-Arch_17_162_11Bud-Arch_17_162_11Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime compositeAnna Alberska0Przemysław Brzyski1Department of Construction, Faculty of Civil Engineering and Architecture, Lublin University of Technology Department of Construction, Faculty of Civil Engineering and Architecture, Lublin University of TechnologyDepartment of Construction, Faculty of Civil Engineering and Architecture, Lublin University of Technology Department of Construction, Faculty of Civil Engineering and Architecture, Lublin University of TechnologyProper design of the building component, which not only meets the legal requirements, but also provides comfort of using of buildings, requires knowledge of the materials and solutions. Since moisture is one of the main factors that can affect the building structure destruction, it is particularly important to be aware of hygrothermal properties of components. And this is the focus of the study. In this paper several variants of external walls were analysed, according to the requirements in terms of: heat transfer coefficient U, the risk of surface and interstitial condensation. Partitions were designed with composite based on shives from industrial hemp and lime binder, which is not yet widely used in Poland. The purpose of the analysis of this material was to prove the validity of using the natural materials in residential buildings.http://bud-arch.pollub.pl/wp-content/uploads/Bud-arch_162_2017_141-151_Alberska_Brzyski.pdfcondensationthermal conductivitymoistureindustrial hemplime |
spellingShingle | Anna Alberska Przemysław Brzyski Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite Budownictwo i Architektura condensation thermal conductivity moisture industrial hemp lime |
title | Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite |
title_full | Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite |
title_fullStr | Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite |
title_full_unstemmed | Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite |
title_short | Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite |
title_sort | analysis of the distribution of temperature and humidity in different variants of external walls made of hemp lime composite |
topic | condensation thermal conductivity moisture industrial hemp lime |
url | http://bud-arch.pollub.pl/wp-content/uploads/Bud-arch_162_2017_141-151_Alberska_Brzyski.pdf |
work_keys_str_mv | AT annaalberska analysisofthedistributionoftemperatureandhumidityindifferentvariantsofexternalwallsmadeofhemplimecomposite AT przemysławbrzyski analysisofthedistributionoftemperatureandhumidityindifferentvariantsofexternalwallsmadeofhemplimecomposite |