Effect of martensitic reversal and grain size on the corrosion and wear behaviour of Cr-Mn steel
In this study, the effect of corrosion and wear behaviour of Cr-Mn steel on fine grains were investigated. The sample were solution annealed (SA) for 1 h at 1050 °C and then cold rolled (CW) to 30%. Further the cold rolled sample were thermally aged (CW + TA) 900 °C for four hours. The findings show...