SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY

The need for water is very important for the production process, the water quality must also be considered the pH value so that the water is suitable for use in boilers or chillers. Seeing from these needs a simulation was made on matlab R2017a using a fuzzy toolbox that can find out the water quali...

Full description

Bibliographic Details
Main Authors: Andhika Irawan, Sri Heranurweni, Titik Nurhayati
Format: Article
Language:Indonesian
Published: Universitas Semarang 2019-04-01
Series:Elektrika
Subjects:
Online Access:http://journals.usm.ac.id/index.php/elektrika/article/view/1541
_version_ 1818381978339115008
author Andhika Irawan
Sri Heranurweni
Titik Nurhayati
author_facet Andhika Irawan
Sri Heranurweni
Titik Nurhayati
author_sort Andhika Irawan
collection DOAJ
description The need for water is very important for the production process, the water quality must also be considered the pH value so that the water is suitable for use in boilers or chillers. Seeing from these needs a simulation was made on matlab R2017a using a fuzzy toolbox that can find out the water quality with fuzzy mamdani method. This fuzzy logic simulation can determine the standard value of boiler water pH (10.5-11.5) and the standard pH value of chiller water (6-8) in the production machine. The methods in fuzzy logic used are mamdani and centroid methods as deffuzification with R2017a matlab simulation tool. The fuzzy inference system used is the mamdani method. This study made a simulation of mamdani method that can determine the quality of the PH water produced by using fuzzy logic. Chiller water pH can be used if iron ion values (0-2 ppm), silica ions (50-150 ppm), Total Dissolved Solid (TDS) (500-1000 ppm), total Hardness (100-200 ppm), M-alkalinity (500-750 ppm) from the standard value, the pH of the chiller water can be proven to reach a water pH value of 6-8. Boiler water pH can be used if iron ion values (0-2 ppm), silica ions (100-150 ppm), Total Dissolved Solid (TDS) (2000-3500 ppm), total Hardness (0-3 ppm), M-alkalinity (700-800 ppm) from the standard value, the pH of boiler water can be proven to reach a water pH value of 10.5-11.5. Keywords: fuzzy logic, Mamdani method, pH of boiler water
first_indexed 2024-12-14T02:43:10Z
format Article
id doaj.art-0a87a749dc8e428780c2b1042918862d
institution Directory Open Access Journal
issn 2085-0565
language Indonesian
last_indexed 2024-12-14T02:43:10Z
publishDate 2019-04-01
publisher Universitas Semarang
record_format Article
series Elektrika
spelling doaj.art-0a87a749dc8e428780c2b1042918862d2022-12-21T23:19:58ZindUniversitas SemarangElektrika2085-05652019-04-01111262910.26623/elektrika.v11i1.15411044SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZYAndhika Irawan0Sri Heranurweni1Titik Nurhayati2Teknik Elektro, Universitas SemarangTeknik Elektro, Universitas SemarangTeknik Elektro, Universitas SemarangThe need for water is very important for the production process, the water quality must also be considered the pH value so that the water is suitable for use in boilers or chillers. Seeing from these needs a simulation was made on matlab R2017a using a fuzzy toolbox that can find out the water quality with fuzzy mamdani method. This fuzzy logic simulation can determine the standard value of boiler water pH (10.5-11.5) and the standard pH value of chiller water (6-8) in the production machine. The methods in fuzzy logic used are mamdani and centroid methods as deffuzification with R2017a matlab simulation tool. The fuzzy inference system used is the mamdani method. This study made a simulation of mamdani method that can determine the quality of the PH water produced by using fuzzy logic. Chiller water pH can be used if iron ion values (0-2 ppm), silica ions (50-150 ppm), Total Dissolved Solid (TDS) (500-1000 ppm), total Hardness (100-200 ppm), M-alkalinity (500-750 ppm) from the standard value, the pH of the chiller water can be proven to reach a water pH value of 6-8. Boiler water pH can be used if iron ion values (0-2 ppm), silica ions (100-150 ppm), Total Dissolved Solid (TDS) (2000-3500 ppm), total Hardness (0-3 ppm), M-alkalinity (700-800 ppm) from the standard value, the pH of boiler water can be proven to reach a water pH value of 10.5-11.5. Keywords: fuzzy logic, Mamdani method, pH of boiler waterhttp://journals.usm.ac.id/index.php/elektrika/article/view/1541fuzzy logic, mamdani method, ph of boiler water
spellingShingle Andhika Irawan
Sri Heranurweni
Titik Nurhayati
SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY
Elektrika
fuzzy logic, mamdani method, ph of boiler water
title SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY
title_full SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY
title_fullStr SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY
title_full_unstemmed SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY
title_short SIMULASI PH AIR UNTUK AIR BOILER DAN AIR CHILLER PADA MESIN PRODUKSI REFRIGERATOR DENGAN MENGGUNAKAN LOGIKA FUZZY
title_sort simulasi ph air untuk air boiler dan air chiller pada mesin produksi refrigerator dengan menggunakan logika fuzzy
topic fuzzy logic, mamdani method, ph of boiler water
url http://journals.usm.ac.id/index.php/elektrika/article/view/1541
work_keys_str_mv AT andhikairawan simulasiphairuntukairboilerdanairchillerpadamesinproduksirefrigeratordenganmenggunakanlogikafuzzy
AT sriheranurweni simulasiphairuntukairboilerdanairchillerpadamesinproduksirefrigeratordenganmenggunakanlogikafuzzy
AT titiknurhayati simulasiphairuntukairboilerdanairchillerpadamesinproduksirefrigeratordenganmenggunakanlogikafuzzy