Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole
In this work, preparation of a molecularly imprinted polymer (MIP) film and its recognition properties for sulfamethoxazolewere investigated. The overoxidized polypyrrole (OPPy) film was prepared by the cyclic voltammetric deposition of pyrrole (Py) in the presence of supporting electrolyte (tetrabu...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2008-12-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/8/12/8463/ |
_version_ | 1811305064443150336 |
---|---|
author | Yücel Sahin Güleren Alsancak Sabriye Perçin Ozkorucuklu |
author_facet | Yücel Sahin Güleren Alsancak Sabriye Perçin Ozkorucuklu |
author_sort | Yücel Sahin |
collection | DOAJ |
description | In this work, preparation of a molecularly imprinted polymer (MIP) film and its recognition properties for sulfamethoxazolewere investigated. The overoxidized polypyrrole (OPPy) film was prepared by the cyclic voltammetric deposition of pyrrole (Py) in the presence of supporting electrolyte (tetrabutylammonium perchlorate-TBAP) with and without a template molecule (sulfamethoxazole) on a pencil graphite electrode (PGE). The voltammetric behaviour of sulfamethoxazole on imprinted and non-imprinted (NIP) films was investigated by differential pulse voltammetry (DPV) in Britton-Robinson (BR) buffer solutions prepared in different ratio of acetonitrile-water binary mixture, between the pH 1.5 and 7.0. The effect of the acetonitrile-water ratio and pH, monomer and template concentrations, electropolymerization cycles on the performance of the MIP electrode was investigated and optimized. The MIP electrode exhibited the best reproducibility and highest sensitivity. The results showed that changing acetonitrile-water ratio and pH of BR buffer solution changes the oxidation peak current values. The highest anodic signal of sulfamethoxazole was obtained in BR buffer solution prepared in 50% (v/v) acetonitrile-water at pH 2.5. The calibration curve for sulfamethoxazole at MIP electrode has linear region for a concentration range of 25.10-3 to 0.75 mM (R2=0.9993). The detection limit of sulfamethoxazole was found as 3.59.10-4 mM (S/N=3). The same method was also applied to determination of sulfamethoxazole in commercial pharmaceutical samples. Method precision (RSD<1%) and recoveries (>87%) were satisfactory. The proposed method is simple and quick. The polypyrrole (PPy) electrodes have low response time, good mechanical stability and are disposable simple to construct. |
first_indexed | 2024-04-13T08:19:46Z |
format | Article |
id | doaj.art-0a8f6d16ff7c475294193690f1d921e4 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-04-13T08:19:46Z |
publishDate | 2008-12-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-0a8f6d16ff7c475294193690f1d921e42022-12-22T02:54:41ZengMDPI AGSensors1424-82202008-12-018128463847810.3390/s8128463Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized PolypyrroleYücel SahinGüleren AlsancakSabriye Perçin OzkorucukluIn this work, preparation of a molecularly imprinted polymer (MIP) film and its recognition properties for sulfamethoxazolewere investigated. The overoxidized polypyrrole (OPPy) film was prepared by the cyclic voltammetric deposition of pyrrole (Py) in the presence of supporting electrolyte (tetrabutylammonium perchlorate-TBAP) with and without a template molecule (sulfamethoxazole) on a pencil graphite electrode (PGE). The voltammetric behaviour of sulfamethoxazole on imprinted and non-imprinted (NIP) films was investigated by differential pulse voltammetry (DPV) in Britton-Robinson (BR) buffer solutions prepared in different ratio of acetonitrile-water binary mixture, between the pH 1.5 and 7.0. The effect of the acetonitrile-water ratio and pH, monomer and template concentrations, electropolymerization cycles on the performance of the MIP electrode was investigated and optimized. The MIP electrode exhibited the best reproducibility and highest sensitivity. The results showed that changing acetonitrile-water ratio and pH of BR buffer solution changes the oxidation peak current values. The highest anodic signal of sulfamethoxazole was obtained in BR buffer solution prepared in 50% (v/v) acetonitrile-water at pH 2.5. The calibration curve for sulfamethoxazole at MIP electrode has linear region for a concentration range of 25.10-3 to 0.75 mM (R2=0.9993). The detection limit of sulfamethoxazole was found as 3.59.10-4 mM (S/N=3). The same method was also applied to determination of sulfamethoxazole in commercial pharmaceutical samples. Method precision (RSD<1%) and recoveries (>87%) were satisfactory. The proposed method is simple and quick. The polypyrrole (PPy) electrodes have low response time, good mechanical stability and are disposable simple to construct.http://www.mdpi.com/1424-8220/8/12/8463/Molecularly imprinted polymeroveroxidized polypyrrolepencil graphite electrodeelectropolymerizationsulfamethoxazolesulfonamides |
spellingShingle | Yücel Sahin Güleren Alsancak Sabriye Perçin Ozkorucuklu Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole Sensors Molecularly imprinted polymer overoxidized polypyrrole pencil graphite electrode electropolymerization sulfamethoxazole sulfonamides |
title | Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole |
title_full | Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole |
title_fullStr | Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole |
title_full_unstemmed | Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole |
title_short | Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole |
title_sort | voltammetric behaviour of sulfamethoxazole on electropolymerized molecularly imprinted overoxidized polypyrrole |
topic | Molecularly imprinted polymer overoxidized polypyrrole pencil graphite electrode electropolymerization sulfamethoxazole sulfonamides |
url | http://www.mdpi.com/1424-8220/8/12/8463/ |
work_keys_str_mv | AT yaƒa1⁄4celsahin voltammetricbehaviourofsulfamethoxazoleonelectropolymerizedmolecularlyimprintedoveroxidizedpolypyrrole AT gaƒa1⁄4lerenalsancak voltammetricbehaviourofsulfamethoxazoleonelectropolymerizedmolecularlyimprintedoveroxidizedpolypyrrole AT sabriyeperaƒainozkorucuklu voltammetricbehaviourofsulfamethoxazoleonelectropolymerizedmolecularlyimprintedoveroxidizedpolypyrrole |