Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report
A 72-year-old male patient was operated by Austin Moore hemiarthroplasty for fracture neck of femur 6 years back who developed multiple complications. In this case, the patient developed dislocation of the hip joint following which the Austin Moore prosthesis got broken. During revision with bipolar...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2020-01-01
|
Series: | Journal of Orthopedics, Traumatology and Rehabilitation |
Subjects: | |
Online Access: | http://www.jotr.in/article.asp?issn=0975-7341;year=2020;volume=12;issue=1;spage=102;epage=105;aulast=Agrawal |
_version_ | 1818261494237757440 |
---|---|
author | Alok Chandra Agrawal Sameer Mittal Harshal Sakale Sandeep Kumar Yadav |
author_facet | Alok Chandra Agrawal Sameer Mittal Harshal Sakale Sandeep Kumar Yadav |
author_sort | Alok Chandra Agrawal |
collection | DOAJ |
description | A 72-year-old male patient was operated by Austin Moore hemiarthroplasty for fracture neck of femur 6 years back who developed multiple complications. In this case, the patient developed dislocation of the hip joint following which the Austin Moore prosthesis got broken. During revision with bipolar hemiarthroplasty, the patient developed fracture of proximal femur which was poorly managed by K-wires and stainless steel wires. After some time, the patient developed dislocation of the bipolar prosthesis and signs of infection. We operated this patient with a two-stage revision. In the first stage following removal of all infected metalwork and debridement, we put antibiotic cement spacer, and after 4 weeks in the second stage, we did a total hip replacement with uncemented constrained proximal femoral modular reconstruction prosthesis. The case is being reported for its rare presentation in genuine management and successful outcome. |
first_indexed | 2024-12-12T18:48:07Z |
format | Article |
id | doaj.art-0b1eff0103d240368d08d162ae317dca |
institution | Directory Open Access Journal |
issn | 0975-7341 |
language | English |
last_indexed | 2024-12-12T18:48:07Z |
publishDate | 2020-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Journal of Orthopedics, Traumatology and Rehabilitation |
spelling | doaj.art-0b1eff0103d240368d08d162ae317dca2022-12-22T00:15:26ZengWolters Kluwer Medknow PublicationsJournal of Orthopedics, Traumatology and Rehabilitation0975-73412020-01-0112110210510.4103/jotr.jotr_18_20Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case reportAlok Chandra AgrawalSameer MittalHarshal SakaleSandeep Kumar YadavA 72-year-old male patient was operated by Austin Moore hemiarthroplasty for fracture neck of femur 6 years back who developed multiple complications. In this case, the patient developed dislocation of the hip joint following which the Austin Moore prosthesis got broken. During revision with bipolar hemiarthroplasty, the patient developed fracture of proximal femur which was poorly managed by K-wires and stainless steel wires. After some time, the patient developed dislocation of the bipolar prosthesis and signs of infection. We operated this patient with a two-stage revision. In the first stage following removal of all infected metalwork and debridement, we put antibiotic cement spacer, and after 4 weeks in the second stage, we did a total hip replacement with uncemented constrained proximal femoral modular reconstruction prosthesis. The case is being reported for its rare presentation in genuine management and successful outcome.http://www.jotr.in/article.asp?issn=0975-7341;year=2020;volume=12;issue=1;spage=102;epage=105;aulast=Agrawalaustin moore hemiarthroplastycomplicationsdislocationelderlyfracture neck of femur |
spellingShingle | Alok Chandra Agrawal Sameer Mittal Harshal Sakale Sandeep Kumar Yadav Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report Journal of Orthopedics, Traumatology and Rehabilitation austin moore hemiarthroplasty complications dislocation elderly fracture neck of femur |
title | Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report |
title_full | Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report |
title_fullStr | Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report |
title_full_unstemmed | Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report |
title_short | Complications following fracture neck of femur treated with austin moore hemiarthroplasty: A rare case report |
title_sort | complications following fracture neck of femur treated with austin moore hemiarthroplasty a rare case report |
topic | austin moore hemiarthroplasty complications dislocation elderly fracture neck of femur |
url | http://www.jotr.in/article.asp?issn=0975-7341;year=2020;volume=12;issue=1;spage=102;epage=105;aulast=Agrawal |
work_keys_str_mv | AT alokchandraagrawal complicationsfollowingfractureneckoffemurtreatedwithaustinmoorehemiarthroplastyararecasereport AT sameermittal complicationsfollowingfractureneckoffemurtreatedwithaustinmoorehemiarthroplastyararecasereport AT harshalsakale complicationsfollowingfractureneckoffemurtreatedwithaustinmoorehemiarthroplastyararecasereport AT sandeepkumaryadav complicationsfollowingfractureneckoffemurtreatedwithaustinmoorehemiarthroplastyararecasereport |