Avoid Bogie Bearing Failure of IGBT Inverter Fed EMUs and Locomotives

Three current paths are proposed, and theoretical analysis and laboratory tests are carried out to investigate the root causes of bearing failure in IGBT inverter-fed locomotives and EMUs. The three types of current paths that run through the drive unit bearings and axle box bearings used on EMUs an...

Full description

Bibliographic Details
Main Authors: Liguo Wang, Xiujuan Yang, Xiangzhen Yan
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Electronics
Subjects:
Online Access:https://www.mdpi.com/2079-9292/12/13/2998