Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions

The influence of a number of factors on the chromatographic properties of statins (atorvastatin, rosuvastatin, simvastatin) in normal-phase and reverse-phase chromatography modes has been studied by the method of the thin-layer chromatography (TLC) in order to select the most effective analytical sy...

Full description

Bibliographic Details
Main Authors: Sumina, Elena G., Kutina, Angelina A., Uglanova, Varsenia Zagidovna
Format: Article
Language:English
Published: Saratov State University 2023-03-01
Series:Известия Саратовского университета. Новая серия: Серия Химия. Биология. Экология
Subjects:
Online Access:https://ichbe.sgu.ru/sites/ichbe.sgu.ru/files/text-pdf/2023/04/himiya_2023_1-28-38.pdf
_version_ 1827932738861137920
author Sumina, Elena G.
Kutina, Angelina A.
Uglanova, Varsenia Zagidovna
author_facet Sumina, Elena G.
Kutina, Angelina A.
Uglanova, Varsenia Zagidovna
author_sort Sumina, Elena G.
collection DOAJ
description The influence of a number of factors on the chromatographic properties of statins (atorvastatin, rosuvastatin, simvastatin) in normal-phase and reverse-phase chromatography modes has been studied by the method of the thin-layer chromatography (TLC) in order to select the most effective analytical systems for the total and separate determination of statins in pharmaceuticals. The study has been performed by ascending TLC on commercial plates with polar, weakly polar, and nonpolar phases. Efficiency and selectivity of chromatographic separation of statins have been established: the nature of the stationary phase (SF), the nature of the mobile phase (MF), the nature and concentration of the organic solvent of the mobile phase, the ionic strength of the solution. It has been revealed that the most effective SF are the reverse-phase plates RP-18, on which statins are separated with a high value of the number of theoretical plates (N) and the lowest value of the height of the equivalent theoretical plate (H). From organic solvents, the aprotic solvent acetonitrile turned out to be effective, which in the MF of the acetonitrile –water composition (70:30) gives the best results of chromatographic separation of statins. It has been found that with an increase in the ionic strength of the solution in the range of 0.1–1.5 mol (KCl), the mobility of statins changes slightly, which is accompanied by a significant blurring of chromatographic zones and deterioration of statin separation, and therefore no strong electrolyte was introduced in further studies. Binary mixtures of atorvastatin and simvastatin have been separated under selected optimal conditions. It has been found that the greatest selectivity of separation is observed in the MF acetonitrile – phosphate buffer (70:30) at pH 3. Quantitative determination of atorvastatin in «Atorvastatin-OBL», «Liprimar» and «Tulip» drugs has been carried out to optimize the chromatography conditions. The correctness and reliability of the determination has been established using the standard drug atorvastatin, Sr did not exceed 0.01–0.02.
first_indexed 2024-03-13T07:13:35Z
format Article
id doaj.art-0b9a8135ad764da097d25979a28d64ef
institution Directory Open Access Journal
issn 1816-9775
2541-8971
language English
last_indexed 2024-03-13T07:13:35Z
publishDate 2023-03-01
publisher Saratov State University
record_format Article
series Известия Саратовского университета. Новая серия: Серия Химия. Биология. Экология
spelling doaj.art-0b9a8135ad764da097d25979a28d64ef2023-06-05T12:08:23ZengSaratov State UniversityИзвестия Саратовского университета. Новая серия: Серия Химия. Биология. Экология1816-97752541-89712023-03-01231283810.18500/1816-9775-2023-23-1-28-38Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutionsSumina, Elena G.0Kutina, Angelina A.1Uglanova, Varsenia Zagidovna2Saratov State University, 83, Astrakhanskaya str., Saratov, 410012, RussiaSaratov State University, 83, Astrakhanskaya str., Saratov, 410012, RussiaSaratov State University, 83, Astrakhanskaya str., Saratov, 410012, RussiaThe influence of a number of factors on the chromatographic properties of statins (atorvastatin, rosuvastatin, simvastatin) in normal-phase and reverse-phase chromatography modes has been studied by the method of the thin-layer chromatography (TLC) in order to select the most effective analytical systems for the total and separate determination of statins in pharmaceuticals. The study has been performed by ascending TLC on commercial plates with polar, weakly polar, and nonpolar phases. Efficiency and selectivity of chromatographic separation of statins have been established: the nature of the stationary phase (SF), the nature of the mobile phase (MF), the nature and concentration of the organic solvent of the mobile phase, the ionic strength of the solution. It has been revealed that the most effective SF are the reverse-phase plates RP-18, on which statins are separated with a high value of the number of theoretical plates (N) and the lowest value of the height of the equivalent theoretical plate (H). From organic solvents, the aprotic solvent acetonitrile turned out to be effective, which in the MF of the acetonitrile –water composition (70:30) gives the best results of chromatographic separation of statins. It has been found that with an increase in the ionic strength of the solution in the range of 0.1–1.5 mol (KCl), the mobility of statins changes slightly, which is accompanied by a significant blurring of chromatographic zones and deterioration of statin separation, and therefore no strong electrolyte was introduced in further studies. Binary mixtures of atorvastatin and simvastatin have been separated under selected optimal conditions. It has been found that the greatest selectivity of separation is observed in the MF acetonitrile – phosphate buffer (70:30) at pH 3. Quantitative determination of atorvastatin in «Atorvastatin-OBL», «Liprimar» and «Tulip» drugs has been carried out to optimize the chromatography conditions. The correctness and reliability of the determination has been established using the standard drug atorvastatin, Sr did not exceed 0.01–0.02.https://ichbe.sgu.ru/sites/ichbe.sgu.ru/files/text-pdf/2023/04/himiya_2023_1-28-38.pdfстатинытонкослойная хроматографияорганические растворителифосфатный буферный раствор
spellingShingle Sumina, Elena G.
Kutina, Angelina A.
Uglanova, Varsenia Zagidovna
Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
Известия Саратовского университета. Новая серия: Серия Химия. Биология. Экология
статины
тонкослойная хроматография
органические растворители
фосфатный буферный раствор
title Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
title_full Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
title_fullStr Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
title_full_unstemmed Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
title_short Thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
title_sort thin layer chromatography of some statins in aqueous organic mobile phases modified with buff er solutions
topic статины
тонкослойная хроматография
органические растворители
фосфатный буферный раствор
url https://ichbe.sgu.ru/sites/ichbe.sgu.ru/files/text-pdf/2023/04/himiya_2023_1-28-38.pdf
work_keys_str_mv AT suminaelenag thinlayerchromatographyofsomestatinsinaqueousorganicmobilephasesmodifiedwithbuffersolutions
AT kutinaangelinaa thinlayerchromatographyofsomestatinsinaqueousorganicmobilephasesmodifiedwithbuffersolutions
AT uglanovavarseniazagidovna thinlayerchromatographyofsomestatinsinaqueousorganicmobilephasesmodifiedwithbuffersolutions