Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing

Background: This study aimed to identify the better arc configuration of volumetric modulated arc therapy (VMAT) for high-grade glioma and glioblastoma, focusing on a dose reduction to the hypothalamic–pituitary axis through an analysis of dose-volumetric parameters, as well as a correlation analysi...

Full description

Bibliographic Details
Main Authors: Eva Y. W. Cheung, Shirley S. H. Ng, Sapphire H. Y. Yung, Dominic Y. T. Cheng, Fandy Y. C. Chan, Janice K. Y. Cheng
Format: Article
Language:English
Published: MDPI AG 2022-01-01
Series:Life
Subjects:
Online Access:https://www.mdpi.com/2075-1729/12/2/195
_version_ 1827654197642788864
author Eva Y. W. Cheung
Shirley S. H. Ng
Sapphire H. Y. Yung
Dominic Y. T. Cheng
Fandy Y. C. Chan
Janice K. Y. Cheng
author_facet Eva Y. W. Cheung
Shirley S. H. Ng
Sapphire H. Y. Yung
Dominic Y. T. Cheng
Fandy Y. C. Chan
Janice K. Y. Cheng
author_sort Eva Y. W. Cheung
collection DOAJ
description Background: This study aimed to identify the better arc configuration of volumetric modulated arc therapy (VMAT) for high-grade glioma and glioblastoma, focusing on a dose reduction to the hypothalamic–pituitary axis through an analysis of dose-volumetric parameters, as well as a correlation analysis between the planned target volume (PTV) to organs at risk (OAR) distance and the radiation dose. Method: Twenty-four patients with 9 high-grade glioma and 15 glioblastomas were included in this study. Identical CT, MRI and structure sets of each patient were used for coplanar VMAT (CO-VMAT), dual planar VMAT (DP-VMAT) and multi-planar VMAT (MP-VMAT) planning. The dose constraints adhered to the RTOG0825 and RTOG9006 protocols. The dose-volumetric parameters of each plan were collected for statistical analysis. Correlation analyses were performed between radiation dose and PTV-OARs distance. Results: The DP-VMAT and MP-VMAT achieved a significant dose reduction to most nearby OARs when compared to CO-VMAT, without compromising the dose to PTV, plan homogeneity and conformity. For centrally located OARs, including the hypothalamus, pituitary, brain stem and optic chiasm, the dose reductions ranged from 2.65 Gy to 3.91 Gy (<i>p</i> < 0.001) in DP-VMAT and from 2.57 Gy to 4 Gy (<i>p</i> < 0.001) in MP-VMAT. Similar dose reduction effects were achieved for contralaterally located OARs, including the hippocampus, optic nerve, lens and retina, ranging from 1.06 Gy to 4.37 Gy in DP-VMAT and from 0.54 Gy to 3.39 Gy in MP-VMAT. For ipsilaterally located OARs, DP-VMAT achieved a significant dose reduction of 1.75 Gy to D<sub>max</sub> for the optic nerve. In the correlation analysis, DP-VMAT and MP-VMAT showed significant dose reductions to centrally located OARs when the PTV-OAR distance was less than 4 cm. In particular, DP-VMAT offered better sparing to the optic chiasm when it was located less than 2 cm from the PTV than that of MP-VMAT and CO-VMAT. DP-VMAT and MP-VMAT also showed better sparing to the contralateral hippocampus and retina when they were located 3–8 cm from the PTV. Conclusion: The proposed DP-VMAT and MP-VMAT demonstrated significant dose reductions to centrally located and contralateral OARs and maintained the high plan qualities to PTV with good homogeneity and conformity when compared to CO-VMAT for high-grade glioma and glioblastoma. The benefit in choosing DP-VMAT and MP-VMAT over CO-VMAT was substantial when the PTV was located near the hypothalamus, pituitary, optic chiasm, contralateral hippocampus and contralateral retina.
first_indexed 2024-03-09T21:34:59Z
format Article
id doaj.art-0bd542ead660463aaa2cf25a6d3c10cc
institution Directory Open Access Journal
issn 2075-1729
language English
last_indexed 2024-03-09T21:34:59Z
publishDate 2022-01-01
publisher MDPI AG
record_format Article
series Life
spelling doaj.art-0bd542ead660463aaa2cf25a6d3c10cc2023-11-23T20:45:37ZengMDPI AGLife2075-17292022-01-0112219510.3390/life12020195Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis SparingEva Y. W. Cheung0Shirley S. H. Ng1Sapphire H. Y. Yung2Dominic Y. T. Cheng3Fandy Y. C. Chan4Janice K. Y. Cheng5School of Medical Health and Sciences, Tung Wah College, 19/F, 31 Wylie Road, Ho Man Tin, Hong Kong, ChinaDepartment of Clinical Oncology, Queen Mary Hospital, Pok Fu Lam, Hong Kong, ChinaSchool of Medical Health and Sciences, Tung Wah College, 19/F, 31 Wylie Road, Ho Man Tin, Hong Kong, ChinaSchool of Medical Health and Sciences, Tung Wah College, 19/F, 31 Wylie Road, Ho Man Tin, Hong Kong, ChinaSchool of Medical Health and Sciences, Tung Wah College, 19/F, 31 Wylie Road, Ho Man Tin, Hong Kong, ChinaSchool of Medical Health and Sciences, Tung Wah College, 19/F, 31 Wylie Road, Ho Man Tin, Hong Kong, ChinaBackground: This study aimed to identify the better arc configuration of volumetric modulated arc therapy (VMAT) for high-grade glioma and glioblastoma, focusing on a dose reduction to the hypothalamic–pituitary axis through an analysis of dose-volumetric parameters, as well as a correlation analysis between the planned target volume (PTV) to organs at risk (OAR) distance and the radiation dose. Method: Twenty-four patients with 9 high-grade glioma and 15 glioblastomas were included in this study. Identical CT, MRI and structure sets of each patient were used for coplanar VMAT (CO-VMAT), dual planar VMAT (DP-VMAT) and multi-planar VMAT (MP-VMAT) planning. The dose constraints adhered to the RTOG0825 and RTOG9006 protocols. The dose-volumetric parameters of each plan were collected for statistical analysis. Correlation analyses were performed between radiation dose and PTV-OARs distance. Results: The DP-VMAT and MP-VMAT achieved a significant dose reduction to most nearby OARs when compared to CO-VMAT, without compromising the dose to PTV, plan homogeneity and conformity. For centrally located OARs, including the hypothalamus, pituitary, brain stem and optic chiasm, the dose reductions ranged from 2.65 Gy to 3.91 Gy (<i>p</i> < 0.001) in DP-VMAT and from 2.57 Gy to 4 Gy (<i>p</i> < 0.001) in MP-VMAT. Similar dose reduction effects were achieved for contralaterally located OARs, including the hippocampus, optic nerve, lens and retina, ranging from 1.06 Gy to 4.37 Gy in DP-VMAT and from 0.54 Gy to 3.39 Gy in MP-VMAT. For ipsilaterally located OARs, DP-VMAT achieved a significant dose reduction of 1.75 Gy to D<sub>max</sub> for the optic nerve. In the correlation analysis, DP-VMAT and MP-VMAT showed significant dose reductions to centrally located OARs when the PTV-OAR distance was less than 4 cm. In particular, DP-VMAT offered better sparing to the optic chiasm when it was located less than 2 cm from the PTV than that of MP-VMAT and CO-VMAT. DP-VMAT and MP-VMAT also showed better sparing to the contralateral hippocampus and retina when they were located 3–8 cm from the PTV. Conclusion: The proposed DP-VMAT and MP-VMAT demonstrated significant dose reductions to centrally located and contralateral OARs and maintained the high plan qualities to PTV with good homogeneity and conformity when compared to CO-VMAT for high-grade glioma and glioblastoma. The benefit in choosing DP-VMAT and MP-VMAT over CO-VMAT was substantial when the PTV was located near the hypothalamus, pituitary, optic chiasm, contralateral hippocampus and contralateral retina.https://www.mdpi.com/2075-1729/12/2/195high-grade gliomaglioblastomavolumetric modulated arc therapymulti-planar VMATdual planar VMAThypothalamus
spellingShingle Eva Y. W. Cheung
Shirley S. H. Ng
Sapphire H. Y. Yung
Dominic Y. T. Cheng
Fandy Y. C. Chan
Janice K. Y. Cheng
Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing
Life
high-grade glioma
glioblastoma
volumetric modulated arc therapy
multi-planar VMAT
dual planar VMAT
hypothalamus
title Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing
title_full Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing
title_fullStr Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing
title_full_unstemmed Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing
title_short Multi-Planar VMAT Plans for High-Grade Glioma and Glioblastoma Targeting the Hypothalamic-Pituitary Axis Sparing
title_sort multi planar vmat plans for high grade glioma and glioblastoma targeting the hypothalamic pituitary axis sparing
topic high-grade glioma
glioblastoma
volumetric modulated arc therapy
multi-planar VMAT
dual planar VMAT
hypothalamus
url https://www.mdpi.com/2075-1729/12/2/195
work_keys_str_mv AT evaywcheung multiplanarvmatplansforhighgradegliomaandglioblastomatargetingthehypothalamicpituitaryaxissparing
AT shirleyshng multiplanarvmatplansforhighgradegliomaandglioblastomatargetingthehypothalamicpituitaryaxissparing
AT sapphirehyyung multiplanarvmatplansforhighgradegliomaandglioblastomatargetingthehypothalamicpituitaryaxissparing
AT dominicytcheng multiplanarvmatplansforhighgradegliomaandglioblastomatargetingthehypothalamicpituitaryaxissparing
AT fandyycchan multiplanarvmatplansforhighgradegliomaandglioblastomatargetingthehypothalamicpituitaryaxissparing
AT janicekycheng multiplanarvmatplansforhighgradegliomaandglioblastomatargetingthehypothalamicpituitaryaxissparing