The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway
The operation of the subway would change the distribution of the ground potential along the rail, forming a DC loop through the grounding points in a nearby regional power grid and threatening the operational safety of the power system. In this paper, a new DC potential distribution calculation meth...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Electronics |
Subjects: | |
Online Access: | https://www.mdpi.com/2079-9292/9/4/613 |
_version_ | 1797571437911867392 |
---|---|
author | Lin Du Sha Chang Shiying Wang |
author_facet | Lin Du Sha Chang Shiying Wang |
author_sort | Lin Du |
collection | DOAJ |
description | The operation of the subway would change the distribution of the ground potential along the rail, forming a DC loop through the grounding points in a nearby regional power grid and threatening the operational safety of the power system. In this paper, a new DC potential distribution calculation method along the subway is firstly proposed. Secondly, a grid grounding DC loop model is built on the foundation of the stray current principle. Thirdly, factors affecting the current in the grid are also presented and discussed based on the grounding loop model. Finally, a subway operation simulation platform is set up in a laboratory to simulate the operation of subway in situation, and the rationality of the model presented in this paper has been effectively verified. |
first_indexed | 2024-03-10T20:40:40Z |
format | Article |
id | doaj.art-0bfa3aa542a2479695f7fcac6d644d4b |
institution | Directory Open Access Journal |
issn | 2079-9292 |
language | English |
last_indexed | 2024-03-10T20:40:40Z |
publishDate | 2020-04-01 |
publisher | MDPI AG |
record_format | Article |
series | Electronics |
spelling | doaj.art-0bfa3aa542a2479695f7fcac6d644d4b2023-11-19T20:41:06ZengMDPI AGElectronics2079-92922020-04-019461310.3390/electronics9040613The Research on DC Loop of Regional Power Grid Caused by the Operation of the SubwayLin Du0Sha Chang1Shiying Wang2State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, ChinaState Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, ChinaState Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, ChinaThe operation of the subway would change the distribution of the ground potential along the rail, forming a DC loop through the grounding points in a nearby regional power grid and threatening the operational safety of the power system. In this paper, a new DC potential distribution calculation method along the subway is firstly proposed. Secondly, a grid grounding DC loop model is built on the foundation of the stray current principle. Thirdly, factors affecting the current in the grid are also presented and discussed based on the grounding loop model. Finally, a subway operation simulation platform is set up in a laboratory to simulate the operation of subway in situation, and the rationality of the model presented in this paper has been effectively verified.https://www.mdpi.com/2079-9292/9/4/613railstray currentgrounding loop modelsimulationDC intrusion |
spellingShingle | Lin Du Sha Chang Shiying Wang The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway Electronics rail stray current grounding loop model simulation DC intrusion |
title | The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway |
title_full | The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway |
title_fullStr | The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway |
title_full_unstemmed | The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway |
title_short | The Research on DC Loop of Regional Power Grid Caused by the Operation of the Subway |
title_sort | research on dc loop of regional power grid caused by the operation of the subway |
topic | rail stray current grounding loop model simulation DC intrusion |
url | https://www.mdpi.com/2079-9292/9/4/613 |
work_keys_str_mv | AT lindu theresearchondcloopofregionalpowergridcausedbytheoperationofthesubway AT shachang theresearchondcloopofregionalpowergridcausedbytheoperationofthesubway AT shiyingwang theresearchondcloopofregionalpowergridcausedbytheoperationofthesubway AT lindu researchondcloopofregionalpowergridcausedbytheoperationofthesubway AT shachang researchondcloopofregionalpowergridcausedbytheoperationofthesubway AT shiyingwang researchondcloopofregionalpowergridcausedbytheoperationofthesubway |