The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China
This study presents the CO<sub>2</sub> emissions and energy performance of traditional raw earth dwellings’ envelope retrofitting located in the Zhushan Village, western Hunan Province, China. The numerical simulations of heating energy consumption on the building models were performed u...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-09-01
|
Series: | Atmosphere |
Subjects: | |
Online Access: | https://www.mdpi.com/2073-4433/13/10/1537 |
_version_ | 1797475382064054272 |
---|---|
author | Liang Xie Zhe Li Jiayu Li Guanglei Yang Jishui Jiang Zhezheng Liu Shuyuan Tong |
author_facet | Liang Xie Zhe Li Jiayu Li Guanglei Yang Jishui Jiang Zhezheng Liu Shuyuan Tong |
author_sort | Liang Xie |
collection | DOAJ |
description | This study presents the CO<sub>2</sub> emissions and energy performance of traditional raw earth dwellings’ envelope retrofitting located in the Zhushan Village, western Hunan Province, China. The numerical simulations of heating energy consumption on the building models were performed using DesignBuilder, an energy simulation program. The energy performance was evaluated using the indexes (including energy consumption, CO<sub>2</sub> emissions, heat balance analysis, and air temperature profiles). The detailed evaluation process of the energy performance is presented as follows. First, the current situation was analyzed through the field research, and two typical building models were built. Second, all schemes were simulated using the DesignBuilder software. Subsequently, the four main retrofit measures (replacing the external insulation windows, setting the external wall insulation layer, setting the roof insulation layer, and setting the ceiling insulation layer) were analyzed, respectively. The optimal parameters of the respective retrofit measure were calculated. Lastly, a multi-objective optimization analysis was conducted on all retrofit plans using the coupling method. In the winter, the results indicated that the “I-shape” dwelling heat consumption of the enclosure structure was reduced by 12.8 kW·h/m<sup>2</sup>, and the CO<sub>2</sub> emissions were reduced by 882.8 kg. While in the benchmark building, the results showed that the “L-shape” dwelling heat consumption of the enclosure structure was decreased by 13.27 kW·h/m<sup>2</sup>, and the CO<sub>2</sub> emissions were reduced by 894.4 kg. As the renewal scheme has been progressively implemented, the whole Zhushan Village will save energy by 11.2 × 10<sup>4</sup> kW·h after the insulation renewal of the envelope structure is completed. |
first_indexed | 2024-03-09T20:44:21Z |
format | Article |
id | doaj.art-0c0f9d77cbce44aa98f79b06091a31f6 |
institution | Directory Open Access Journal |
issn | 2073-4433 |
language | English |
last_indexed | 2024-03-09T20:44:21Z |
publishDate | 2022-09-01 |
publisher | MDPI AG |
record_format | Article |
series | Atmosphere |
spelling | doaj.art-0c0f9d77cbce44aa98f79b06091a31f62023-11-23T22:49:41ZengMDPI AGAtmosphere2073-44332022-09-011310153710.3390/atmos13101537The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, ChinaLiang Xie0Zhe Li1Jiayu Li2Guanglei Yang3Jishui Jiang4Zhezheng Liu5Shuyuan Tong6School of Architecture and Art, Central South University, Changsha 410075, ChinaSchool of Architecture and Art, Central South University, Changsha 410075, ChinaSchool of Architecture and Art, Central South University, Changsha 410075, ChinaSchool of Architecture and Art, Central South University, Changsha 410075, ChinaSchool of Architecture and Art, Central South University, Changsha 410075, ChinaSchool of Architecture and Art, Central South University, Changsha 410075, ChinaSchool of Architecture and Art, Central South University, Changsha 410075, ChinaThis study presents the CO<sub>2</sub> emissions and energy performance of traditional raw earth dwellings’ envelope retrofitting located in the Zhushan Village, western Hunan Province, China. The numerical simulations of heating energy consumption on the building models were performed using DesignBuilder, an energy simulation program. The energy performance was evaluated using the indexes (including energy consumption, CO<sub>2</sub> emissions, heat balance analysis, and air temperature profiles). The detailed evaluation process of the energy performance is presented as follows. First, the current situation was analyzed through the field research, and two typical building models were built. Second, all schemes were simulated using the DesignBuilder software. Subsequently, the four main retrofit measures (replacing the external insulation windows, setting the external wall insulation layer, setting the roof insulation layer, and setting the ceiling insulation layer) were analyzed, respectively. The optimal parameters of the respective retrofit measure were calculated. Lastly, a multi-objective optimization analysis was conducted on all retrofit plans using the coupling method. In the winter, the results indicated that the “I-shape” dwelling heat consumption of the enclosure structure was reduced by 12.8 kW·h/m<sup>2</sup>, and the CO<sub>2</sub> emissions were reduced by 882.8 kg. While in the benchmark building, the results showed that the “L-shape” dwelling heat consumption of the enclosure structure was decreased by 13.27 kW·h/m<sup>2</sup>, and the CO<sub>2</sub> emissions were reduced by 894.4 kg. As the renewal scheme has been progressively implemented, the whole Zhushan Village will save energy by 11.2 × 10<sup>4</sup> kW·h after the insulation renewal of the envelope structure is completed.https://www.mdpi.com/2073-4433/13/10/1537west of Hunanraw earth dwellingwinter thermal insulationenergy savingCO<sub>2</sub> emission |
spellingShingle | Liang Xie Zhe Li Jiayu Li Guanglei Yang Jishui Jiang Zhezheng Liu Shuyuan Tong The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China Atmosphere west of Hunan raw earth dwelling winter thermal insulation energy saving CO<sub>2</sub> emission |
title | The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China |
title_full | The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China |
title_fullStr | The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China |
title_full_unstemmed | The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China |
title_short | The Impact of Traditional Raw Earth Dwellings’ Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China |
title_sort | impact of traditional raw earth dwellings envelope retrofitting on energy saving a case study from zhushan village in west of hunan china |
topic | west of Hunan raw earth dwelling winter thermal insulation energy saving CO<sub>2</sub> emission |
url | https://www.mdpi.com/2073-4433/13/10/1537 |
work_keys_str_mv | AT liangxie theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT zheli theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT jiayuli theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT guangleiyang theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT jishuijiang theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT zhezhengliu theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT shuyuantong theimpactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT liangxie impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT zheli impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT jiayuli impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT guangleiyang impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT jishuijiang impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT zhezhengliu impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina AT shuyuantong impactoftraditionalrawearthdwellingsenveloperetrofittingonenergysavingacasestudyfromzhushanvillageinwestofhunanchina |