The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device
Fluorescent reporters have revolutionized modern applications in the fields of molecular and synthetic biology, enabling applications ranging from education to point-of-care diagnostics. Past advancements in these fields have primarily focused on improving reaction conditions, the development of new...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
KeAi Communications Co., Ltd.
2021-06-01
|
Series: | Synthetic and Systems Biotechnology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405805X21000211 |
_version_ | 1797203408866770944 |
---|---|
author | Logan R. Burrington Emran Baryal Katherine Hui Emmett Lambert Sarah T. Harding Javin P. Oza |
author_facet | Logan R. Burrington Emran Baryal Katherine Hui Emmett Lambert Sarah T. Harding Javin P. Oza |
author_sort | Logan R. Burrington |
collection | DOAJ |
description | Fluorescent reporters have revolutionized modern applications in the fields of molecular and synthetic biology, enabling applications ranging from education to point-of-care diagnostics. Past advancements in these fields have primarily focused on improving reaction conditions, the development of new applications, and the broad dissemination of these technologies. However, field and classroom-based applications have remained limited in part due to the nature of fluorescent signal detection, which often requires the use of costly lab equipment to observe and quantify fluorescence readouts. Users without access to laboratory equipment rely on qualitative assessments of fluorescence, a process that remains highly variable from user-to-user even within the same classroom. To overcome this challenge, we have developed a foldable illuminator and incubator device to support field-applications of synthetic biology-based biosensors for education and diagnostics. The Fold-Illuminator is an affordable, portable, and recyclable device that allows for the visible detection of fluorescent biomolecules. The Fold-Illuminator's design allows for assembly in under 10 min, a user can then utilize the optional heating element to incubate biochemical reactions and visualize fluorescence outputs in a defined and light-controlled environment. Interchangeable LED strips and light-filtering screens provide modularity to pair with the fluorescence wavelengths of interest. The user can then unfold the device for convenient storage, transport, or even recycling. The cost for the Fold-Illuminator is $5.58 USD and is compatible with an optional heating element for an additional $3.98 cost, with potential for further reductions in cost for larger quantities. Open-source templates for cutting device parts from paper stock are provided for both printing and cutting by hand; cutting can also be achieved with consumer-grade smart cutting machines such as the Cricut®. Combined with the broad applications of fluorescent reporters, the Fold-Illuminator has the potential to improve access to fluorescence visualization and quantification for new users as well as emerging field applications. |
first_indexed | 2024-04-24T08:18:52Z |
format | Article |
id | doaj.art-0c303fa914a349378684c36bed3fd487 |
institution | Directory Open Access Journal |
issn | 2405-805X |
language | English |
last_indexed | 2024-04-24T08:18:52Z |
publishDate | 2021-06-01 |
publisher | KeAi Communications Co., Ltd. |
record_format | Article |
series | Synthetic and Systems Biotechnology |
spelling | doaj.art-0c303fa914a349378684c36bed3fd4872024-04-17T01:50:51ZengKeAi Communications Co., Ltd.Synthetic and Systems Biotechnology2405-805X2021-06-016295101The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator deviceLogan R. Burrington0Emran Baryal1Katherine Hui2Emmett Lambert3Sarah T. Harding4Javin P. Oza5Chemistry and Biochemistry Department, College of Science and Math, California Polytechnic State University, San Luis Obispo, CA, 93407, USAMechanical Engineering Department, College of Engineering, California Polytechnic State University, San Luis Obispo, CA, 93407, USAMechanical Engineering Department, College of Engineering, California Polytechnic State University, San Luis Obispo, CA, 93407, USAMechanical Engineering Department, College of Engineering, California Polytechnic State University, San Luis Obispo, CA, 93407, USAMechanical Engineering Department, College of Engineering, California Polytechnic State University, San Luis Obispo, CA, 93407, USAChemistry and Biochemistry Department, College of Science and Math, California Polytechnic State University, San Luis Obispo, CA, 93407, USA; Corresponding author.Fluorescent reporters have revolutionized modern applications in the fields of molecular and synthetic biology, enabling applications ranging from education to point-of-care diagnostics. Past advancements in these fields have primarily focused on improving reaction conditions, the development of new applications, and the broad dissemination of these technologies. However, field and classroom-based applications have remained limited in part due to the nature of fluorescent signal detection, which often requires the use of costly lab equipment to observe and quantify fluorescence readouts. Users without access to laboratory equipment rely on qualitative assessments of fluorescence, a process that remains highly variable from user-to-user even within the same classroom. To overcome this challenge, we have developed a foldable illuminator and incubator device to support field-applications of synthetic biology-based biosensors for education and diagnostics. The Fold-Illuminator is an affordable, portable, and recyclable device that allows for the visible detection of fluorescent biomolecules. The Fold-Illuminator's design allows for assembly in under 10 min, a user can then utilize the optional heating element to incubate biochemical reactions and visualize fluorescence outputs in a defined and light-controlled environment. Interchangeable LED strips and light-filtering screens provide modularity to pair with the fluorescence wavelengths of interest. The user can then unfold the device for convenient storage, transport, or even recycling. The cost for the Fold-Illuminator is $5.58 USD and is compatible with an optional heating element for an additional $3.98 cost, with potential for further reductions in cost for larger quantities. Open-source templates for cutting device parts from paper stock are provided for both printing and cutting by hand; cutting can also be achieved with consumer-grade smart cutting machines such as the Cricut®. Combined with the broad applications of fluorescent reporters, the Fold-Illuminator has the potential to improve access to fluorescence visualization and quantification for new users as well as emerging field applications.http://www.sciencedirect.com/science/article/pii/S2405805X21000211IlluminatorIncubatorFluorescent reporterEducationDiagnosticsFrugal science |
spellingShingle | Logan R. Burrington Emran Baryal Katherine Hui Emmett Lambert Sarah T. Harding Javin P. Oza The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device Synthetic and Systems Biotechnology Illuminator Incubator Fluorescent reporter Education Diagnostics Frugal science |
title | The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device |
title_full | The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device |
title_fullStr | The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device |
title_full_unstemmed | The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device |
title_short | The Fold-Illuminator: A low-cost, portable, and disposable incubator-illuminator device |
title_sort | fold illuminator a low cost portable and disposable incubator illuminator device |
topic | Illuminator Incubator Fluorescent reporter Education Diagnostics Frugal science |
url | http://www.sciencedirect.com/science/article/pii/S2405805X21000211 |
work_keys_str_mv | AT loganrburrington thefoldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT emranbaryal thefoldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT katherinehui thefoldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT emmettlambert thefoldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT sarahtharding thefoldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT javinpoza thefoldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT loganrburrington foldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT emranbaryal foldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT katherinehui foldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT emmettlambert foldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT sarahtharding foldilluminatoralowcostportableanddisposableincubatorilluminatordevice AT javinpoza foldilluminatoralowcostportableanddisposableincubatorilluminatordevice |