Green fat removal in the analysis of polychlorinated biphenyls in biotic samples

A green analytical method based on the use of a deep eutectic solvent (DES) has been proposed for fat removal in the analysis of polychlorinated biphenyl (PCBs) in biotic samples. Using priority PCB congeners as model compounds, a novel sample preparation approach fully avoiding the use of mineral a...

Full description

Bibliographic Details
Main Authors: J. Bintanel-Cenis, L. Herrero, B. Gómara, L. Ramos
Format: Article
Language:English
Published: Elsevier 2023-08-01
Series:Advances in Sample Preparation
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2772582023000311
_version_ 1797690178149548032
author J. Bintanel-Cenis
L. Herrero
B. Gómara
L. Ramos
author_facet J. Bintanel-Cenis
L. Herrero
B. Gómara
L. Ramos
author_sort J. Bintanel-Cenis
collection DOAJ
description A green analytical method based on the use of a deep eutectic solvent (DES) has been proposed for fat removal in the analysis of polychlorinated biphenyl (PCBs) in biotic samples. Using priority PCB congeners as model compounds, a novel sample preparation approach fully avoiding the use of mineral acids has been developed. Once optimized, the procedure allowed fat removal to be accomplished by 30min treatment with [chlorine chloride]:[oxalic acid dihydrated] 1:1 molar ratio at 60°C, with 3s vortexing every 5min to facilitate the homogenization of the slurry. Then, the target PCBs were recovered from the slurry by 20min extraction with 4mL of n-hexane. This DES-based method was combined with gas chromatography-quadrupole mass spectrometry (GC-qMS) for final PCB determination. The complete analytical method provided satisfactory recoveries of the target compounds (above 87% for all analytes), using as a small amount of sample as 0.150g. The repeatability of the complete procedure, expressed as relative standard deviation, was less than 5%, and the intermediate precision better than 14%. Final validation of the proposed methodology included the satisfactory comparison of the concentrations calculated for the endogenous PCBs in selected fatty foodstuffs with lipid contents under 18% (w/w fresh weight, fw) with those found when the same samples were analyzed by a more conventional and accepted reference procedure. The limits of detection were in all cases lower than 30 pg/g fw (as calculated for real samples), demonstrating the feasibility of the proposed procedure for accurate determination of the target compounds in biotic samples.
first_indexed 2024-03-12T01:55:49Z
format Article
id doaj.art-0c5891bc29814698816e27cedd92ecf3
institution Directory Open Access Journal
issn 2772-5820
language English
last_indexed 2024-03-12T01:55:49Z
publishDate 2023-08-01
publisher Elsevier
record_format Article
series Advances in Sample Preparation
spelling doaj.art-0c5891bc29814698816e27cedd92ecf32023-09-08T04:34:23ZengElsevierAdvances in Sample Preparation2772-58202023-08-017100081Green fat removal in the analysis of polychlorinated biphenyls in biotic samplesJ. Bintanel-Cenis0L. Herrero1B. Gómara2L. Ramos3Department Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, Madrid, SpainDepartment Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, Madrid, SpainDepartment Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, Madrid, SpainCorresponding author.; Department Instrumental Analysis and Environmental Chemistry, IQOG-CSIC, Juan de la Cierva 3, Madrid, SpainA green analytical method based on the use of a deep eutectic solvent (DES) has been proposed for fat removal in the analysis of polychlorinated biphenyl (PCBs) in biotic samples. Using priority PCB congeners as model compounds, a novel sample preparation approach fully avoiding the use of mineral acids has been developed. Once optimized, the procedure allowed fat removal to be accomplished by 30min treatment with [chlorine chloride]:[oxalic acid dihydrated] 1:1 molar ratio at 60°C, with 3s vortexing every 5min to facilitate the homogenization of the slurry. Then, the target PCBs were recovered from the slurry by 20min extraction with 4mL of n-hexane. This DES-based method was combined with gas chromatography-quadrupole mass spectrometry (GC-qMS) for final PCB determination. The complete analytical method provided satisfactory recoveries of the target compounds (above 87% for all analytes), using as a small amount of sample as 0.150g. The repeatability of the complete procedure, expressed as relative standard deviation, was less than 5%, and the intermediate precision better than 14%. Final validation of the proposed methodology included the satisfactory comparison of the concentrations calculated for the endogenous PCBs in selected fatty foodstuffs with lipid contents under 18% (w/w fresh weight, fw) with those found when the same samples were analyzed by a more conventional and accepted reference procedure. The limits of detection were in all cases lower than 30 pg/g fw (as calculated for real samples), demonstrating the feasibility of the proposed procedure for accurate determination of the target compounds in biotic samples.http://www.sciencedirect.com/science/article/pii/S2772582023000311Green sample preparationDeep eutectic solventsFat removalPolychlorinated biphenylsBiotic samplesFood analysis
spellingShingle J. Bintanel-Cenis
L. Herrero
B. Gómara
L. Ramos
Green fat removal in the analysis of polychlorinated biphenyls in biotic samples
Advances in Sample Preparation
Green sample preparation
Deep eutectic solvents
Fat removal
Polychlorinated biphenyls
Biotic samples
Food analysis
title Green fat removal in the analysis of polychlorinated biphenyls in biotic samples
title_full Green fat removal in the analysis of polychlorinated biphenyls in biotic samples
title_fullStr Green fat removal in the analysis of polychlorinated biphenyls in biotic samples
title_full_unstemmed Green fat removal in the analysis of polychlorinated biphenyls in biotic samples
title_short Green fat removal in the analysis of polychlorinated biphenyls in biotic samples
title_sort green fat removal in the analysis of polychlorinated biphenyls in biotic samples
topic Green sample preparation
Deep eutectic solvents
Fat removal
Polychlorinated biphenyls
Biotic samples
Food analysis
url http://www.sciencedirect.com/science/article/pii/S2772582023000311
work_keys_str_mv AT jbintanelcenis greenfatremovalintheanalysisofpolychlorinatedbiphenylsinbioticsamples
AT lherrero greenfatremovalintheanalysisofpolychlorinatedbiphenylsinbioticsamples
AT bgomara greenfatremovalintheanalysisofpolychlorinatedbiphenylsinbioticsamples
AT lramos greenfatremovalintheanalysisofpolychlorinatedbiphenylsinbioticsamples