Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method

Nafion®-nanostructured polyaniline (nsPANi) composite film is prepared using cyclic voltammetry (CV) and immobilized with creatinine deiminase (CD) enzyme and is used to sense creatinine in a buffer phosphate solution. The conditions for preparing Nafion®-nsPANi composite film are optimized by using...

Full description

Bibliographic Details
Main Authors: Jing-Shan Do, Yu-Hsuan Chang
Format: Article
Language:English
Published: Elsevier 2023-06-01
Series:Sensors and Actuators Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666053922000625
_version_ 1797802695106494464
author Jing-Shan Do
Yu-Hsuan Chang
author_facet Jing-Shan Do
Yu-Hsuan Chang
author_sort Jing-Shan Do
collection DOAJ
description Nafion®-nanostructured polyaniline (nsPANi) composite film is prepared using cyclic voltammetry (CV) and immobilized with creatinine deiminase (CD) enzyme and is used to sense creatinine in a buffer phosphate solution. The conditions for preparing Nafion®-nsPANi composite film are optimized by using a mixture design for which the sensitivity is the response. The relationship between the sensitivity of the amperometric creatinine biosensor (y) and the normalized aniline concentration (Y1), HCl concentration (Y2) and scanning rate (Y3) is y = 119.44Y1 + 45.23Y2 + 100.93Y3 + 255.69Y1Y2 + 313.16Y1Y3 + 430.56Y1Y2Y3The maximum sensitivity of an amperometric creatinine biosensor that is constructed using Nafion®-nsPANi composite film in 0.0943 M aniline, 0.9024 M HCl and using a scanning rate of 27.88 mV s − 1 is 2013.2 μA mM−1 cm−2, which is 54.9% better than the sensitivity of a conventional experimental technique. The amperometric creatinine biosensor is 6.60% less sensitive after sensing 0.15 mM creatinine 240 times. The amperometric creatinine biosensor incurs insignificant interference in 0.138 mM urea, 0.085 mM ascorbic acid (AA) and 5.54 mM glucose.
first_indexed 2024-03-13T05:09:35Z
format Article
id doaj.art-0cfe1ea62b8c47029382c3ca9c3173fe
institution Directory Open Access Journal
issn 2666-0539
language English
last_indexed 2024-03-13T05:09:35Z
publishDate 2023-06-01
publisher Elsevier
record_format Article
series Sensors and Actuators Reports
spelling doaj.art-0cfe1ea62b8c47029382c3ca9c3173fe2023-06-16T05:11:39ZengElsevierSensors and Actuators Reports2666-05392023-06-015100135Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design methodJing-Shan Do0Yu-Hsuan Chang1Corresponding author.; Department of Chemical and Materials Engineering, National Chin-Yi University of Technology, Taichung, ChinaDepartment of Chemical and Materials Engineering, National Chin-Yi University of Technology, Taichung, ChinaNafion®-nanostructured polyaniline (nsPANi) composite film is prepared using cyclic voltammetry (CV) and immobilized with creatinine deiminase (CD) enzyme and is used to sense creatinine in a buffer phosphate solution. The conditions for preparing Nafion®-nsPANi composite film are optimized by using a mixture design for which the sensitivity is the response. The relationship between the sensitivity of the amperometric creatinine biosensor (y) and the normalized aniline concentration (Y1), HCl concentration (Y2) and scanning rate (Y3) is y = 119.44Y1 + 45.23Y2 + 100.93Y3 + 255.69Y1Y2 + 313.16Y1Y3 + 430.56Y1Y2Y3The maximum sensitivity of an amperometric creatinine biosensor that is constructed using Nafion®-nsPANi composite film in 0.0943 M aniline, 0.9024 M HCl and using a scanning rate of 27.88 mV s − 1 is 2013.2 μA mM−1 cm−2, which is 54.9% better than the sensitivity of a conventional experimental technique. The amperometric creatinine biosensor is 6.60% less sensitive after sensing 0.15 mM creatinine 240 times. The amperometric creatinine biosensor incurs insignificant interference in 0.138 mM urea, 0.085 mM ascorbic acid (AA) and 5.54 mM glucose.http://www.sciencedirect.com/science/article/pii/S2666053922000625CreatinineAmperometric biosensorNafion®-nanostructured polyaniline composite filmMixture designOptimization
spellingShingle Jing-Shan Do
Yu-Hsuan Chang
Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method
Sensors and Actuators Reports
Creatinine
Amperometric biosensor
Nafion®-nanostructured polyaniline composite film
Mixture design
Optimization
title Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method
title_full Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method
title_fullStr Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method
title_full_unstemmed Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method
title_short Optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase/Nafion®-nanostructured polyaniline composite film by mixture design method
title_sort optimizing the sensing performance of amperometric creatinine detection based on creatinine deiminase nafion r nanostructured polyaniline composite film by mixture design method
topic Creatinine
Amperometric biosensor
Nafion®-nanostructured polyaniline composite film
Mixture design
Optimization
url http://www.sciencedirect.com/science/article/pii/S2666053922000625
work_keys_str_mv AT jingshando optimizingthesensingperformanceofamperometriccreatininedetectionbasedoncreatininedeiminasenafionnanostructuredpolyanilinecompositefilmbymixturedesignmethod
AT yuhsuanchang optimizingthesensingperformanceofamperometriccreatininedetectionbasedoncreatininedeiminasenafionnanostructuredpolyanilinecompositefilmbymixturedesignmethod