The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis

This study produces an image of theoretical and experimental case of high loading stumbling condition for hip prosthesis. Model had been studied namely Charnley. This model was modeled with finite element method by using ANSYS software, the effect of changing the design parameters (head diameter, n...

Full description

Bibliographic Details
Main Authors: Ahmed Abdul Hussain, Mahmood Wael Saeed
Format: Article
Language:English
Published: University of Baghdad 2023-06-01
Series:Journal of Engineering
Subjects:
Online Access:https://joe.uobaghdad.edu.iq/index.php/main/article/view/2241
_version_ 1797786750188257280
author Ahmed Abdul Hussain
Mahmood Wael Saeed
author_facet Ahmed Abdul Hussain
Mahmood Wael Saeed
author_sort Ahmed Abdul Hussain
collection DOAJ
description This study produces an image of theoretical and experimental case of high loading stumbling condition for hip prosthesis. Model had been studied namely Charnley. This model was modeled with finite element method by using ANSYS software, the effect of changing the design parameters (head diameter, neck length, neck ratio, stem length) on Charnley design, for stumbling case as impact load where the load reach to (8.7* body weight) for impact duration of 0.005sec.An experimental rig had been constructed to test the hip model, this rig consist of a wood box with a smooth sliding shaft where a load of 1 pound is dropped from three heights. The strain produced by this impact is measured by using rosette strain gauge connected to Wheatstone bridge for the model .The signal is amplified and sent forward to a data acquisition and then saved in the connected laptop. From this study it is found that the changing in stem length had large effect on effective stress where the change in effective stress while stem length increased from (110mm to 140mm) was not more than (209MPa).
first_indexed 2024-03-13T01:12:18Z
format Article
id doaj.art-0d48dd2bb3ef428a89abdaa73a027e92
institution Directory Open Access Journal
issn 1726-4073
2520-3339
language English
last_indexed 2024-03-13T01:12:18Z
publishDate 2023-06-01
publisher University of Baghdad
record_format Article
series Journal of Engineering
spelling doaj.art-0d48dd2bb3ef428a89abdaa73a027e922023-07-05T15:48:35ZengUniversity of BaghdadJournal of Engineering1726-40732520-33392023-06-01200710.31026/j.eng.2014.07.08The Effect of Dynamic Loading on Stresses Induced in Charnley Hip ProsthesisAhmed Abdul HussainMahmood Wael Saeed This study produces an image of theoretical and experimental case of high loading stumbling condition for hip prosthesis. Model had been studied namely Charnley. This model was modeled with finite element method by using ANSYS software, the effect of changing the design parameters (head diameter, neck length, neck ratio, stem length) on Charnley design, for stumbling case as impact load where the load reach to (8.7* body weight) for impact duration of 0.005sec.An experimental rig had been constructed to test the hip model, this rig consist of a wood box with a smooth sliding shaft where a load of 1 pound is dropped from three heights. The strain produced by this impact is measured by using rosette strain gauge connected to Wheatstone bridge for the model .The signal is amplified and sent forward to a data acquisition and then saved in the connected laptop. From this study it is found that the changing in stem length had large effect on effective stress where the change in effective stress while stem length increased from (110mm to 140mm) was not more than (209MPa). https://joe.uobaghdad.edu.iq/index.php/main/article/view/2241hip prosthesis; charnley design; finite element method; design parameters; data acquisition
spellingShingle Ahmed Abdul Hussain
Mahmood Wael Saeed
The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis
Journal of Engineering
hip prosthesis; charnley design; finite element method; design parameters; data acquisition
title The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis
title_full The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis
title_fullStr The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis
title_full_unstemmed The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis
title_short The Effect of Dynamic Loading on Stresses Induced in Charnley Hip Prosthesis
title_sort effect of dynamic loading on stresses induced in charnley hip prosthesis
topic hip prosthesis; charnley design; finite element method; design parameters; data acquisition
url https://joe.uobaghdad.edu.iq/index.php/main/article/view/2241
work_keys_str_mv AT ahmedabdulhussain theeffectofdynamicloadingonstressesinducedincharnleyhipprosthesis
AT mahmoodwaelsaeed theeffectofdynamicloadingonstressesinducedincharnleyhipprosthesis
AT ahmedabdulhussain effectofdynamicloadingonstressesinducedincharnleyhipprosthesis
AT mahmoodwaelsaeed effectofdynamicloadingonstressesinducedincharnleyhipprosthesis