Application of the Active-Fluidics System in Phacoemulsification: A Review

The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by the bottle height, which is relatively constant, wh...

Full description

Bibliographic Details
Main Authors: Yu Luo, Guangcan Xu, Hongyu Li, Tianju Ma, Zi Ye, Zhaohui Li
Format: Article
Language:English
Published: MDPI AG 2023-01-01
Series:Journal of Clinical Medicine
Subjects:
Online Access:https://www.mdpi.com/2077-0383/12/2/611
_version_ 1797440583467270144
author Yu Luo
Guangcan Xu
Hongyu Li
Tianju Ma
Zi Ye
Zhaohui Li
author_facet Yu Luo
Guangcan Xu
Hongyu Li
Tianju Ma
Zi Ye
Zhaohui Li
author_sort Yu Luo
collection DOAJ
description The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by the bottle height, which is relatively constant, while the active-fluidics system is paired with a cassette that contains pressure sensors to monitor intraocular pressure changes. The active-fluidics system allows surgeons to preset a target intraocular pressure value, and it replenishes the fluids proactively; thus, the intraocular pressure is consistently maintained near the target value. Under such circumstances, stable intraocular pressure and anterior chamber volume values could be acquired. Research on surgical safety, efficiency and results have reported several strengths of the active-fluidics system. It is also advantageous in some complicated cataract surgeries. However, the system is not widely used at present, mainly due to its low penetration rate and high equipment cost. Some of its updates such as the new Active Sentry handpiece showed potential superiority in laboratory studies recently, but there is still further research to be conducted. This article gives an overview of the mechanism and performance of the active-fluidics system, and it is expected to provide clues for future research.
first_indexed 2024-03-09T12:10:16Z
format Article
id doaj.art-0de6fa3291114c8aac4d5df22686a494
institution Directory Open Access Journal
issn 2077-0383
language English
last_indexed 2024-03-09T12:10:16Z
publishDate 2023-01-01
publisher MDPI AG
record_format Article
series Journal of Clinical Medicine
spelling doaj.art-0de6fa3291114c8aac4d5df22686a4942023-11-30T22:52:22ZengMDPI AGJournal of Clinical Medicine2077-03832023-01-0112261110.3390/jcm12020611Application of the Active-Fluidics System in Phacoemulsification: A ReviewYu Luo0Guangcan Xu1Hongyu Li2Tianju Ma3Zi Ye4Zhaohui Li5Medical School of Chinese People’s Liberation Army, Beijing 100853, ChinaDepartment of Ophthalmology, Chinese People’s Liberation Army General Hospital, Beijing 100853, ChinaMedical School of Chinese People’s Liberation Army, Beijing 100853, ChinaDepartment of Ophthalmology, Chinese People’s Liberation Army General Hospital, Beijing 100853, ChinaDepartment of Ophthalmology, Chinese People’s Liberation Army General Hospital, Beijing 100853, ChinaMedical School of Chinese People’s Liberation Army, Beijing 100853, ChinaThe fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by the bottle height, which is relatively constant, while the active-fluidics system is paired with a cassette that contains pressure sensors to monitor intraocular pressure changes. The active-fluidics system allows surgeons to preset a target intraocular pressure value, and it replenishes the fluids proactively; thus, the intraocular pressure is consistently maintained near the target value. Under such circumstances, stable intraocular pressure and anterior chamber volume values could be acquired. Research on surgical safety, efficiency and results have reported several strengths of the active-fluidics system. It is also advantageous in some complicated cataract surgeries. However, the system is not widely used at present, mainly due to its low penetration rate and high equipment cost. Some of its updates such as the new Active Sentry handpiece showed potential superiority in laboratory studies recently, but there is still further research to be conducted. This article gives an overview of the mechanism and performance of the active-fluidics system, and it is expected to provide clues for future research.https://www.mdpi.com/2077-0383/12/2/611cataractphacoemulsificationactive-fluidics systemgravity-fluidics system
spellingShingle Yu Luo
Guangcan Xu
Hongyu Li
Tianju Ma
Zi Ye
Zhaohui Li
Application of the Active-Fluidics System in Phacoemulsification: A Review
Journal of Clinical Medicine
cataract
phacoemulsification
active-fluidics system
gravity-fluidics system
title Application of the Active-Fluidics System in Phacoemulsification: A Review
title_full Application of the Active-Fluidics System in Phacoemulsification: A Review
title_fullStr Application of the Active-Fluidics System in Phacoemulsification: A Review
title_full_unstemmed Application of the Active-Fluidics System in Phacoemulsification: A Review
title_short Application of the Active-Fluidics System in Phacoemulsification: A Review
title_sort application of the active fluidics system in phacoemulsification a review
topic cataract
phacoemulsification
active-fluidics system
gravity-fluidics system
url https://www.mdpi.com/2077-0383/12/2/611
work_keys_str_mv AT yuluo applicationoftheactivefluidicssysteminphacoemulsificationareview
AT guangcanxu applicationoftheactivefluidicssysteminphacoemulsificationareview
AT hongyuli applicationoftheactivefluidicssysteminphacoemulsificationareview
AT tianjuma applicationoftheactivefluidicssysteminphacoemulsificationareview
AT ziye applicationoftheactivefluidicssysteminphacoemulsificationareview
AT zhaohuili applicationoftheactivefluidicssysteminphacoemulsificationareview