Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)

The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date...

Full description

Bibliographic Details
Main Authors: V. Sinha, A. C. Nölscher, S. Bockisch, T. Klüpfel, J. Williams
Format: Article
Language:English
Published: Copernicus Publications 2012-12-01
Series:Atmospheric Measurement Techniques
Online Access:http://www.atmos-meas-tech.net/5/2981/2012/amt-5-2981-2012.pdf
_version_ 1818158696865202176
author V. Sinha
A. C. Nölscher
S. Bockisch
T. Klüpfel
J. Williams
author_facet V. Sinha
A. C. Nölscher
S. Bockisch
T. Klüpfel
J. Williams
author_sort V. Sinha
collection DOAJ
description The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. <br><br> Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s), sensitivity (LOD 3–6 s<sup>−1</sup>) and overall uncertainty (25% in optimum conditions) for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical alternative for groups interested in total OH reactivity observations.
first_indexed 2024-12-11T15:34:12Z
format Article
id doaj.art-0e02324cf3494740abcfa818594357ee
institution Directory Open Access Journal
issn 1867-1381
1867-8548
language English
last_indexed 2024-12-11T15:34:12Z
publishDate 2012-12-01
publisher Copernicus Publications
record_format Article
series Atmospheric Measurement Techniques
spelling doaj.art-0e02324cf3494740abcfa818594357ee2022-12-22T00:59:58ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482012-12-015122981299210.5194/amt-5-2981-2012Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)V. SinhaA. C. NölscherS. BockischT. KlüpfelJ. WilliamsThe primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. <br><br> Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s), sensitivity (LOD 3–6 s<sup>−1</sup>) and overall uncertainty (25% in optimum conditions) for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical alternative for groups interested in total OH reactivity observations.http://www.atmos-meas-tech.net/5/2981/2012/amt-5-2981-2012.pdf
spellingShingle V. Sinha
A. C. Nölscher
S. Bockisch
T. Klüpfel
J. Williams
Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
Atmospheric Measurement Techniques
title Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
title_full Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
title_fullStr Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
title_full_unstemmed Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
title_short Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
title_sort total oh reactivity measurements using a new fast gas chromatographic photo ionization detector gc pid
url http://www.atmos-meas-tech.net/5/2981/2012/amt-5-2981-2012.pdf
work_keys_str_mv AT vsinha totalohreactivitymeasurementsusinganewfastgaschromatographicphotoionizationdetectorgcpid
AT acnolscher totalohreactivitymeasurementsusinganewfastgaschromatographicphotoionizationdetectorgcpid
AT sbockisch totalohreactivitymeasurementsusinganewfastgaschromatographicphotoionizationdetectorgcpid
AT tklupfel totalohreactivitymeasurementsusinganewfastgaschromatographicphotoionizationdetectorgcpid
AT jwilliams totalohreactivitymeasurementsusinganewfastgaschromatographicphotoionizationdetectorgcpid