Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording

In an increasingly interconnected world, where electronic devices permeate every aspect of our lives, wearable systems aimed at monitoring physiological signals are rapidly taking over the sport and fitness domain, as well as biomedical fields such as rehabilitation and prosthetics. With the intent...

Full description

Bibliographic Details
Main Authors: Antonello Mascia, Riccardo Collu, Andrea Spanu, Matteo Fraschini, Massimo Barbaro, Piero Cosseddu
Format: Article
Language:English
Published: MDPI AG 2023-01-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/23/2/766
_version_ 1797437276309946368
author Antonello Mascia
Riccardo Collu
Andrea Spanu
Matteo Fraschini
Massimo Barbaro
Piero Cosseddu
author_facet Antonello Mascia
Riccardo Collu
Andrea Spanu
Matteo Fraschini
Massimo Barbaro
Piero Cosseddu
author_sort Antonello Mascia
collection DOAJ
description In an increasingly interconnected world, where electronic devices permeate every aspect of our lives, wearable systems aimed at monitoring physiological signals are rapidly taking over the sport and fitness domain, as well as biomedical fields such as rehabilitation and prosthetics. With the intent of providing a novel approach to the field, in this paper we discuss the development of a wearable system for the acquisition of EEG signals based on a portable, low-power custom PCB specifically designed to be used in combination with non-conventional ultra-conformable and imperceptible Parylene-C tattoo electrodes. The proposed system has been tested in a standard rest-state experiment, and its performance in terms of discrimination of two different states has been compared to that of a commercial wearable device for EEG signal acquisition (i.e., the Muse headset), showing comparable results. This first preliminary validation demonstrates the possibility of conveniently employing ultra-conformable tattoo-electrodes integrated portable systems for the unobtrusive acquisition of brain activity.
first_indexed 2024-03-09T11:16:33Z
format Article
id doaj.art-0e2ad0af8b144a7f96730a2c9ec99fea
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-09T11:16:33Z
publishDate 2023-01-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-0e2ad0af8b144a7f96730a2c9ec99fea2023-12-01T00:27:14ZengMDPI AGSensors1424-82202023-01-0123276610.3390/s23020766Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG RecordingAntonello Mascia0Riccardo Collu1Andrea Spanu2Matteo Fraschini3Massimo Barbaro4Piero Cosseddu5Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, ItalyDepartment of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, ItalyDepartment of Science, Technology and Society, Scuola Universitaria Superiore IUSS, Palazzo del Broletto, Piazza della Vittoria 15, 27100 Pavia, ItalyDepartment of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, ItalyDepartment of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, ItalyDepartment of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, ItalyIn an increasingly interconnected world, where electronic devices permeate every aspect of our lives, wearable systems aimed at monitoring physiological signals are rapidly taking over the sport and fitness domain, as well as biomedical fields such as rehabilitation and prosthetics. With the intent of providing a novel approach to the field, in this paper we discuss the development of a wearable system for the acquisition of EEG signals based on a portable, low-power custom PCB specifically designed to be used in combination with non-conventional ultra-conformable and imperceptible Parylene-C tattoo electrodes. The proposed system has been tested in a standard rest-state experiment, and its performance in terms of discrimination of two different states has been compared to that of a commercial wearable device for EEG signal acquisition (i.e., the Muse headset), showing comparable results. This first preliminary validation demonstrates the possibility of conveniently employing ultra-conformable tattoo-electrodes integrated portable systems for the unobtrusive acquisition of brain activity.https://www.mdpi.com/1424-8220/23/2/766Parylene Cdry tattoo electrodeswearable electronic systemEEG
spellingShingle Antonello Mascia
Riccardo Collu
Andrea Spanu
Matteo Fraschini
Massimo Barbaro
Piero Cosseddu
Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording
Sensors
Parylene C
dry tattoo electrodes
wearable electronic system
EEG
title Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording
title_full Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording
title_fullStr Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording
title_full_unstemmed Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording
title_short Wearable System Based on Ultra-Thin Parylene C Tattoo Electrodes for EEG Recording
title_sort wearable system based on ultra thin parylene c tattoo electrodes for eeg recording
topic Parylene C
dry tattoo electrodes
wearable electronic system
EEG
url https://www.mdpi.com/1424-8220/23/2/766
work_keys_str_mv AT antonellomascia wearablesystembasedonultrathinparylenectattooelectrodesforeegrecording
AT riccardocollu wearablesystembasedonultrathinparylenectattooelectrodesforeegrecording
AT andreaspanu wearablesystembasedonultrathinparylenectattooelectrodesforeegrecording
AT matteofraschini wearablesystembasedonultrathinparylenectattooelectrodesforeegrecording
AT massimobarbaro wearablesystembasedonultrathinparylenectattooelectrodesforeegrecording
AT pierocosseddu wearablesystembasedonultrathinparylenectattooelectrodesforeegrecording