Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme
Circular-array-based photoacoustic computed tomography (CA-PACT) is a promising imaging tool owing to its broad acoustic detection coverage and fidelity. However, CA-PACT suffers from poor image quality outside the focal zone along both elevational and lateral dimensions. To address this challenge,...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-08-01
|
Series: | Photoacoustics |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2213597923000903 |
_version_ | 1797730996403044352 |
---|---|
author | Rongkang Gao Tao Chen Yaguang Ren Liangjian Liu Ningbo Chen Kenneth K.Y. Wong Liang Song Xiaohui Ma Chengbo Liu |
author_facet | Rongkang Gao Tao Chen Yaguang Ren Liangjian Liu Ningbo Chen Kenneth K.Y. Wong Liang Song Xiaohui Ma Chengbo Liu |
author_sort | Rongkang Gao |
collection | DOAJ |
description | Circular-array-based photoacoustic computed tomography (CA-PACT) is a promising imaging tool owing to its broad acoustic detection coverage and fidelity. However, CA-PACT suffers from poor image quality outside the focal zone along both elevational and lateral dimensions. To address this challenge, we proposed a novel reconstruction strategy by integrating the synthetic aperture focusing technique (SAFT) with the 2nd derivative-based back projection (2nd D-BP) algorithm to restore the image quality outside the focal zone along both the elevational and lateral axes. The proposed solution is a two-phase reconstruction scheme. In the first phase, with the assistance of an acoustic lens, we designed a circular array-based SAFT algorithm to restore the resolution and SNR along the elevational axis. The acoustic lens pushes the boundary of the upper limit of the SAFT scheme to achieve enhanced elevational resolution. In the second phase, we proposed a 2nd D-BP scheme to improve the lateral resolution and suppress noises in 3D imaging results. The 2nd D-BP strategy enhances the image quality along the lateral dimension by up-converting the high spatial frequencies of the object’s absorption pattern. We validated the effectiveness of the proposed strategy using both phantoms and in vivo human experiments. The experimental results demonstrated superior image quality (7-fold enhancement in elevational resolution, 3-fold enhancement in lateral resolution, and an 11-dB increase in SNR). This strategy provides a new paradigm in the PACT system as it significantly enhances the spatial resolution and imaging contrast in both the elevational and lateral dimensions while maintaining a large focal zone. |
first_indexed | 2024-03-12T11:53:09Z |
format | Article |
id | doaj.art-0e591ab2a9694fada0b4dce7f21e64f9 |
institution | Directory Open Access Journal |
issn | 2213-5979 |
language | English |
last_indexed | 2024-03-12T11:53:09Z |
publishDate | 2023-08-01 |
publisher | Elsevier |
record_format | Article |
series | Photoacoustics |
spelling | doaj.art-0e591ab2a9694fada0b4dce7f21e64f92023-08-31T05:02:45ZengElsevierPhotoacoustics2213-59792023-08-0132100537Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection schemeRongkang Gao0Tao Chen1Yaguang Ren2Liangjian Liu3Ningbo Chen4Kenneth K.Y. Wong5Liang Song6Xiaohui Ma7Chengbo Liu8Research Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, ChinaResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, ChinaResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, ChinaResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, ChinaResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; The University of Hong Kong, Department of Electrical and Electronic Engineering, Hong Kong ChinaThe University of Hong Kong, Department of Electrical and Electronic Engineering, Hong Kong ChinaResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, ChinaThe first medical center of Chinese PLA General Hospital, the Department of Vascular and Endovascular Surgery, Beijing, ChinaResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; Corresponding author.Circular-array-based photoacoustic computed tomography (CA-PACT) is a promising imaging tool owing to its broad acoustic detection coverage and fidelity. However, CA-PACT suffers from poor image quality outside the focal zone along both elevational and lateral dimensions. To address this challenge, we proposed a novel reconstruction strategy by integrating the synthetic aperture focusing technique (SAFT) with the 2nd derivative-based back projection (2nd D-BP) algorithm to restore the image quality outside the focal zone along both the elevational and lateral axes. The proposed solution is a two-phase reconstruction scheme. In the first phase, with the assistance of an acoustic lens, we designed a circular array-based SAFT algorithm to restore the resolution and SNR along the elevational axis. The acoustic lens pushes the boundary of the upper limit of the SAFT scheme to achieve enhanced elevational resolution. In the second phase, we proposed a 2nd D-BP scheme to improve the lateral resolution and suppress noises in 3D imaging results. The 2nd D-BP strategy enhances the image quality along the lateral dimension by up-converting the high spatial frequencies of the object’s absorption pattern. We validated the effectiveness of the proposed strategy using both phantoms and in vivo human experiments. The experimental results demonstrated superior image quality (7-fold enhancement in elevational resolution, 3-fold enhancement in lateral resolution, and an 11-dB increase in SNR). This strategy provides a new paradigm in the PACT system as it significantly enhances the spatial resolution and imaging contrast in both the elevational and lateral dimensions while maintaining a large focal zone.http://www.sciencedirect.com/science/article/pii/S2213597923000903Circular array transducerPACTAcoustic lensSAFTRe-derivativeBack projection |
spellingShingle | Rongkang Gao Tao Chen Yaguang Ren Liangjian Liu Ningbo Chen Kenneth K.Y. Wong Liang Song Xiaohui Ma Chengbo Liu Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme Photoacoustics Circular array transducer PACT Acoustic lens SAFT Re-derivative Back projection |
title | Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme |
title_full | Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme |
title_fullStr | Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme |
title_full_unstemmed | Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme |
title_short | Restoring the imaging quality of circular transducer array-based PACT using synthetic aperture focusing technique integrated with 2nd-derivative-based back projection scheme |
title_sort | restoring the imaging quality of circular transducer array based pact using synthetic aperture focusing technique integrated with 2nd derivative based back projection scheme |
topic | Circular array transducer PACT Acoustic lens SAFT Re-derivative Back projection |
url | http://www.sciencedirect.com/science/article/pii/S2213597923000903 |
work_keys_str_mv | AT rongkanggao restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT taochen restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT yaguangren restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT liangjianliu restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT ningbochen restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT kennethkywong restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT liangsong restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT xiaohuima restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme AT chengboliu restoringtheimagingqualityofcirculartransducerarraybasedpactusingsyntheticaperturefocusingtechniqueintegratedwith2ndderivativebasedbackprojectionscheme |