Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies

A single particle instrument was developed for real-time analysis of organic aerosol. This instrument, named Single Particle Laser Ablation Mass Spectrometry (SPLAM), samples particles using an aerodynamic lens system for which the theoretical performances were calculated. At the outlet of this syst...

Full description

Bibliographic Details
Main Authors: F. Gaie-Levrel, S. Perrier, E. Perraudin, C. Stoll, N. Grand, M. Schwell
Format: Article
Language:English
Published: Copernicus Publications 2012-01-01
Series:Atmospheric Measurement Techniques
Online Access:http://www.atmos-meas-tech.net/5/225/2012/amt-5-225-2012.pdf
_version_ 1811276435566886912
author F. Gaie-Levrel
S. Perrier
E. Perraudin
C. Stoll
N. Grand
M. Schwell
author_facet F. Gaie-Levrel
S. Perrier
E. Perraudin
C. Stoll
N. Grand
M. Schwell
author_sort F. Gaie-Levrel
collection DOAJ
description A single particle instrument was developed for real-time analysis of organic aerosol. This instrument, named Single Particle Laser Ablation Mass Spectrometry (SPLAM), samples particles using an aerodynamic lens system for which the theoretical performances were calculated. At the outlet of this system, particle detection and sizing are realized by using two continuous diode lasers operating at λ = 403 nm. Polystyrene Latex (PSL), sodium chloride (NaCl) and dioctylphtalate (DOP) particles were used to characterize and calibrate optical detection of SPLAM. The optical detection limit (DL) and detection efficiency (DE) were determined using size-selected DOP particles. The DE ranges from 0.1 to 90% for 100 and 350 nm DOP particles respectively and the SPLAM instrument is able to detect and size-resolve particles as small as 110–120 nm. During optical detection, particle scattered light from the two diode lasers, is detected by two photomultipliers and the detected signals are used to trigger UV excimer laser (λ = 248 nm) used for one-step laser desorption ionization (LDI) of individual aerosol particles. The formed ions are analyzed by a 1 m linear time-of-flight mass spectrometer in order to access to the chemical composition of individual particles. The TOF-MS detection limit for gaseous aromatic compounds was determined to be 0.85 × 10<sup>−15</sup> kg (∼4 × 10<sup>3</sup> molecules). DOP particles were also used to test the overall operation of the instrument. The analysis of a secondary organic aerosol, formed in a smog chamber by the ozonolysis of indene, is presented as a first application of the instrument. Single particle mass spectra were obtained with an effective hit rate of 8%. Some of these mass spectra were found to be very different from one particle to another possibly reflecting chemical differences within the investigated indene SOA particles. Our study shows that an exhaustive statistical analysis, over hundreds of particles, and adapted reference mass spectra are further needed to understand the chemical meaning of single particle mass spectra of chemically complex submicrometer-sized organic aerosols.
first_indexed 2024-04-12T23:56:29Z
format Article
id doaj.art-0e66022095f24c83877a17f1ec91da72
institution Directory Open Access Journal
issn 1867-1381
1867-8548
language English
last_indexed 2024-04-12T23:56:29Z
publishDate 2012-01-01
publisher Copernicus Publications
record_format Article
series Atmospheric Measurement Techniques
spelling doaj.art-0e66022095f24c83877a17f1ec91da722022-12-22T03:11:28ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482012-01-015122524110.5194/amt-5-225-2012Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studiesF. Gaie-LevrelS. PerrierE. PerraudinC. StollN. GrandM. SchwellA single particle instrument was developed for real-time analysis of organic aerosol. This instrument, named Single Particle Laser Ablation Mass Spectrometry (SPLAM), samples particles using an aerodynamic lens system for which the theoretical performances were calculated. At the outlet of this system, particle detection and sizing are realized by using two continuous diode lasers operating at λ = 403 nm. Polystyrene Latex (PSL), sodium chloride (NaCl) and dioctylphtalate (DOP) particles were used to characterize and calibrate optical detection of SPLAM. The optical detection limit (DL) and detection efficiency (DE) were determined using size-selected DOP particles. The DE ranges from 0.1 to 90% for 100 and 350 nm DOP particles respectively and the SPLAM instrument is able to detect and size-resolve particles as small as 110–120 nm. During optical detection, particle scattered light from the two diode lasers, is detected by two photomultipliers and the detected signals are used to trigger UV excimer laser (λ = 248 nm) used for one-step laser desorption ionization (LDI) of individual aerosol particles. The formed ions are analyzed by a 1 m linear time-of-flight mass spectrometer in order to access to the chemical composition of individual particles. The TOF-MS detection limit for gaseous aromatic compounds was determined to be 0.85 × 10<sup>−15</sup> kg (∼4 × 10<sup>3</sup> molecules). DOP particles were also used to test the overall operation of the instrument. The analysis of a secondary organic aerosol, formed in a smog chamber by the ozonolysis of indene, is presented as a first application of the instrument. Single particle mass spectra were obtained with an effective hit rate of 8%. Some of these mass spectra were found to be very different from one particle to another possibly reflecting chemical differences within the investigated indene SOA particles. Our study shows that an exhaustive statistical analysis, over hundreds of particles, and adapted reference mass spectra are further needed to understand the chemical meaning of single particle mass spectra of chemically complex submicrometer-sized organic aerosols.http://www.atmos-meas-tech.net/5/225/2012/amt-5-225-2012.pdf
spellingShingle F. Gaie-Levrel
S. Perrier
E. Perraudin
C. Stoll
N. Grand
M. Schwell
Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies
Atmospheric Measurement Techniques
title Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies
title_full Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies
title_fullStr Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies
title_full_unstemmed Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies
title_short Development and characterization of a single particle laser ablation mass spectrometer (SPLAM) for organic aerosol studies
title_sort development and characterization of a single particle laser ablation mass spectrometer splam for organic aerosol studies
url http://www.atmos-meas-tech.net/5/225/2012/amt-5-225-2012.pdf
work_keys_str_mv AT fgaielevrel developmentandcharacterizationofasingleparticlelaserablationmassspectrometersplamfororganicaerosolstudies
AT sperrier developmentandcharacterizationofasingleparticlelaserablationmassspectrometersplamfororganicaerosolstudies
AT eperraudin developmentandcharacterizationofasingleparticlelaserablationmassspectrometersplamfororganicaerosolstudies
AT cstoll developmentandcharacterizationofasingleparticlelaserablationmassspectrometersplamfororganicaerosolstudies
AT ngrand developmentandcharacterizationofasingleparticlelaserablationmassspectrometersplamfororganicaerosolstudies
AT mschwell developmentandcharacterizationofasingleparticlelaserablationmassspectrometersplamfororganicaerosolstudies