Snaring Self-Expanding Devices to Facilitate Transcatheter Aortic Valve Replacement in Patients with Complex Aortic Anatomies

The snare-assisted technique has been described to facilitate transcatheter aortic valve replacement (TAVR) delivery system advancement in complex aortic anatomies. However, the evidence is limited to case reports. To evaluate the safety profile of the snare-facilitated approach and its impact on se...

Full description

Bibliographic Details
Main Authors: Yi-Jun Yao, Zhen-Gang Zhao, Xi Wang, Yong Peng, Jia-Fu Wei, Sen He, Yi-Jian Li, Jing-Jing He, Zhong-Kai Zhu, Yuan Feng, Mao Chen
Format: Article
Language:English
Published: MDPI AG 2023-08-01
Series:Journal of Clinical Medicine
Subjects:
Online Access:https://www.mdpi.com/2077-0383/12/15/5067
Description
Summary:The snare-assisted technique has been described to facilitate transcatheter aortic valve replacement (TAVR) delivery system advancement in complex aortic anatomies. However, the evidence is limited to case reports. To evaluate the safety profile of the snare-facilitated approach and its impact on self-expanding (SE) TAVR outcomes, we collected consecutive patients who underwent transfemoral SE-TAVR for aortic stenosis, using propensity score matching (PSM) separately in tricuspid and type-0 and type-1 bicuspid aortic valve morphology between the snare and non-snare groups. In 766 patients, despite the snare group having significantly larger annulus angulation and maximal ascending aortic diameter, both groups achieved comparable 30-day device success rates, regardless of first-generation or new-generation valve use. After PSM, the snare group had a significantly lower new permanent pacemaker implantation rate among 193 type-0 patients (3.3% vs. 18.3%, <i>p</i> = 0.01). The ipsilateral group used new-generation valves less frequently (23.0% vs. 75.4%, <i>p</i> < 0.001), but there were no significant inter-group differences in procedure-related events, except for a lower incidence of PVL ≥ mild in the ipsilateral group (14.9% vs. 32.3%, <i>p</i> = 0.01). In conclusion, the snare-assisted technique appears useful in SE-TAVR with angulated aortic root anatomy, and the benefits were comparable between ipsilateral and contralateral snare techniques.
ISSN:2077-0383