Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.

<h4>Purpose</h4>To determine whether the semi-automated two-dimensional echocardiography (2DE) layer strain software, compared to cardiac magnetic resonance (CMR), is reliable for left ventricular (LV) volume quantification.<h4>Methods and results</h4>We retrospectively selec...

Full description

Bibliographic Details
Main Authors: Tetsuji Kitano, Yosuke Nabeshima, Yasuhiko Abe, Yutaka Otsuji, Masaaki Takeuchi
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0221204
_version_ 1819140226701852672
author Tetsuji Kitano
Yosuke Nabeshima
Yasuhiko Abe
Yutaka Otsuji
Masaaki Takeuchi
author_facet Tetsuji Kitano
Yosuke Nabeshima
Yasuhiko Abe
Yutaka Otsuji
Masaaki Takeuchi
author_sort Tetsuji Kitano
collection DOAJ
description <h4>Purpose</h4>To determine whether the semi-automated two-dimensional echocardiography (2DE) layer strain software, compared to cardiac magnetic resonance (CMR), is reliable for left ventricular (LV) volume quantification.<h4>Methods and results</h4>We retrospectively selected 84 patients who underwent CMR and 2DE on the same day. Novel 2DE layer strain software automatically provides LV contour in 3 myocardial layers and performs layer specific speckle tracking analysis, which calculates LV volumes, ejection fraction (LVEF), and global longitudinal strain (GLS) in each layer. These values were compared with reference values from CMR disk-area summation and feature tracking methods. Coverage probability (CP) was determined using predefined cut-off values and absolute differences in LV volumes of 30 mL, those in LVEF of 10%, and those in GLS of 4%. The software did not work in 3 patients (feasibility: 96%). Different layers resulted in different degrees of under- or over-estimation of LV volumes. Epicardial tracking significantly overestimated the LV volumes and significantly underestimated LVEF and GLS. Mid-myocardial tracking had less underestimation of LV volumes and equivalent CP values of LVEF (0.77 vs. 0.75 using the disk-area summation method and 0.90 vs. 0.94 using the feature tracking method) and GLS (0.95 vs. 0.92) compared with endocardial tracking. The new software showed excellent reproducibility, especially endocardial and mid-myocardial tracking.<h4>Conclusions</h4>Mid-myocardial tracking with the novel 2DE strain software provided less bias of LV volumes with high CP values of LVEF and GLS, which suggests that mid-myocardial layer speckle tracking analysis approximates CMR derived LV functional parameters.
first_indexed 2024-12-22T11:35:12Z
format Article
id doaj.art-0ea96ea1dbcb4892b08e837b5d2da143
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-22T11:35:12Z
publishDate 2019-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-0ea96ea1dbcb4892b08e837b5d2da1432022-12-21T18:27:27ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-01148e022120410.1371/journal.pone.0221204Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.Tetsuji KitanoYosuke NabeshimaYasuhiko AbeYutaka OtsujiMasaaki Takeuchi<h4>Purpose</h4>To determine whether the semi-automated two-dimensional echocardiography (2DE) layer strain software, compared to cardiac magnetic resonance (CMR), is reliable for left ventricular (LV) volume quantification.<h4>Methods and results</h4>We retrospectively selected 84 patients who underwent CMR and 2DE on the same day. Novel 2DE layer strain software automatically provides LV contour in 3 myocardial layers and performs layer specific speckle tracking analysis, which calculates LV volumes, ejection fraction (LVEF), and global longitudinal strain (GLS) in each layer. These values were compared with reference values from CMR disk-area summation and feature tracking methods. Coverage probability (CP) was determined using predefined cut-off values and absolute differences in LV volumes of 30 mL, those in LVEF of 10%, and those in GLS of 4%. The software did not work in 3 patients (feasibility: 96%). Different layers resulted in different degrees of under- or over-estimation of LV volumes. Epicardial tracking significantly overestimated the LV volumes and significantly underestimated LVEF and GLS. Mid-myocardial tracking had less underestimation of LV volumes and equivalent CP values of LVEF (0.77 vs. 0.75 using the disk-area summation method and 0.90 vs. 0.94 using the feature tracking method) and GLS (0.95 vs. 0.92) compared with endocardial tracking. The new software showed excellent reproducibility, especially endocardial and mid-myocardial tracking.<h4>Conclusions</h4>Mid-myocardial tracking with the novel 2DE strain software provided less bias of LV volumes with high CP values of LVEF and GLS, which suggests that mid-myocardial layer speckle tracking analysis approximates CMR derived LV functional parameters.https://doi.org/10.1371/journal.pone.0221204
spellingShingle Tetsuji Kitano
Yosuke Nabeshima
Yasuhiko Abe
Yutaka Otsuji
Masaaki Takeuchi
Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.
PLoS ONE
title Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.
title_full Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.
title_fullStr Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.
title_full_unstemmed Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.
title_short Accuracy and reliability of novel semi-automated two-dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function.
title_sort accuracy and reliability of novel semi automated two dimensional layer specific speckle tracking software for quantifying left ventricular volumes and function
url https://doi.org/10.1371/journal.pone.0221204
work_keys_str_mv AT tetsujikitano accuracyandreliabilityofnovelsemiautomatedtwodimensionallayerspecificspeckletrackingsoftwareforquantifyingleftventricularvolumesandfunction
AT yosukenabeshima accuracyandreliabilityofnovelsemiautomatedtwodimensionallayerspecificspeckletrackingsoftwareforquantifyingleftventricularvolumesandfunction
AT yasuhikoabe accuracyandreliabilityofnovelsemiautomatedtwodimensionallayerspecificspeckletrackingsoftwareforquantifyingleftventricularvolumesandfunction
AT yutakaotsuji accuracyandreliabilityofnovelsemiautomatedtwodimensionallayerspecificspeckletrackingsoftwareforquantifyingleftventricularvolumesandfunction
AT masaakitakeuchi accuracyandreliabilityofnovelsemiautomatedtwodimensionallayerspecificspeckletrackingsoftwareforquantifyingleftventricularvolumesandfunction