Shear and filtration strength of foundation of channel type hydropower plant building

The purpose of the study was to analyze the foundation's filtration strength and the HPP building's shear stability after 38 years of operation as part of the Tuyamuyun hydroelectric complex on the Amudarya River. The analysis was carried out based on field data obtained with the help of 1...

Full description

Bibliographic Details
Main Authors: Bakiev Masharif, Babajanova Nodira, Babajanov Kakhramon, Khasanov Khojiakbar
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/02/e3sconf_conmechydro2023_03025.pdf
_version_ 1828048689954816000
author Bakiev Masharif
Babajanova Nodira
Babajanov Kakhramon
Khasanov Khojiakbar
author_facet Bakiev Masharif
Babajanova Nodira
Babajanov Kakhramon
Khasanov Khojiakbar
author_sort Bakiev Masharif
collection DOAJ
description The purpose of the study was to analyze the foundation's filtration strength and the HPP building's shear stability after 38 years of operation as part of the Tuyamuyun hydroelectric complex on the Amudarya River. The analysis was carried out based on field data obtained with the help of 16 piezometers installed in two alignments within the block of the HPP building and vertical drainages in the grassland. The constructed graphs of water pressure fluctuations in piezometers coincide with the nature of the change in the water level in the upper and lower pools. The actual gradients did not exceed the allowable gradient for the shaly sand interlayer and limestone bedding fracture filler. Comparison of the maximum natural gradients and those calculated from model studies using electrohydrodynamic analogies. The stability of the HPP building block is estimated by the maximum piezometric pressure and compared with analytical calculations, and the safety factor is 2.303. In this way, the base's filtration strength and the structure's shear stability are ensured in the entire range of changes in the operating mode of the pressure front of the HPP building block.
first_indexed 2024-04-10T18:59:44Z
format Article
id doaj.art-0ee3d466a8904200bd2574d0d53d2f72
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-04-10T18:59:44Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-0ee3d466a8904200bd2574d0d53d2f722023-01-31T09:54:02ZengEDP SciencesE3S Web of Conferences2267-12422023-01-013650302510.1051/e3sconf/202336503025e3sconf_conmechydro2023_03025Shear and filtration strength of foundation of channel type hydropower plant buildingBakiev Masharif0Babajanova Nodira1Babajanov Kakhramon2Khasanov Khojiakbar3“Tashkent Institute of Irrigation and Agricultural Mechanization Engineers” National Research University“Tashkent Institute of Irrigation and Agricultural Mechanization Engineers” National Research UniversityGUP «Suvloyiha»“Tashkent Institute of Irrigation and Agricultural Mechanization Engineers” National Research UniversityThe purpose of the study was to analyze the foundation's filtration strength and the HPP building's shear stability after 38 years of operation as part of the Tuyamuyun hydroelectric complex on the Amudarya River. The analysis was carried out based on field data obtained with the help of 16 piezometers installed in two alignments within the block of the HPP building and vertical drainages in the grassland. The constructed graphs of water pressure fluctuations in piezometers coincide with the nature of the change in the water level in the upper and lower pools. The actual gradients did not exceed the allowable gradient for the shaly sand interlayer and limestone bedding fracture filler. Comparison of the maximum natural gradients and those calculated from model studies using electrohydrodynamic analogies. The stability of the HPP building block is estimated by the maximum piezometric pressure and compared with analytical calculations, and the safety factor is 2.303. In this way, the base's filtration strength and the structure's shear stability are ensured in the entire range of changes in the operating mode of the pressure front of the HPP building block.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/02/e3sconf_conmechydro2023_03025.pdf
spellingShingle Bakiev Masharif
Babajanova Nodira
Babajanov Kakhramon
Khasanov Khojiakbar
Shear and filtration strength of foundation of channel type hydropower plant building
E3S Web of Conferences
title Shear and filtration strength of foundation of channel type hydropower plant building
title_full Shear and filtration strength of foundation of channel type hydropower plant building
title_fullStr Shear and filtration strength of foundation of channel type hydropower plant building
title_full_unstemmed Shear and filtration strength of foundation of channel type hydropower plant building
title_short Shear and filtration strength of foundation of channel type hydropower plant building
title_sort shear and filtration strength of foundation of channel type hydropower plant building
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/02/e3sconf_conmechydro2023_03025.pdf
work_keys_str_mv AT bakievmasharif shearandfiltrationstrengthoffoundationofchanneltypehydropowerplantbuilding
AT babajanovanodira shearandfiltrationstrengthoffoundationofchanneltypehydropowerplantbuilding
AT babajanovkakhramon shearandfiltrationstrengthoffoundationofchanneltypehydropowerplantbuilding
AT khasanovkhojiakbar shearandfiltrationstrengthoffoundationofchanneltypehydropowerplantbuilding