Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms

Abstract Background A significant proportion of the radiation dose from a PET-CT examination is dependent on the CT protocol, which should be optimised for clinical purposes. Matching protocols on different scanners within an imaging centre is important for the consistency of image quality and dose....

Full description

Bibliographic Details
Main Authors: Sarah-May Gould, Jane Mackewn, Sugama Chicklore, Gary J. R. Cook, Andrew Mallia, Lucy Pike
Format: Article
Language:English
Published: SpringerOpen 2021-07-01
Series:EJNMMI Physics
Subjects:
Online Access:https://doi.org/10.1186/s40658-021-00404-4
_version_ 1818903514055704576
author Sarah-May Gould
Jane Mackewn
Sugama Chicklore
Gary J. R. Cook
Andrew Mallia
Lucy Pike
author_facet Sarah-May Gould
Jane Mackewn
Sugama Chicklore
Gary J. R. Cook
Andrew Mallia
Lucy Pike
author_sort Sarah-May Gould
collection DOAJ
description Abstract Background A significant proportion of the radiation dose from a PET-CT examination is dependent on the CT protocol, which should be optimised for clinical purposes. Matching protocols on different scanners within an imaging centre is important for the consistency of image quality and dose. This paper describes our experience translating low-dose CT protocols between scanner models utilising different automatic exposure control (AEC) methods and reconstruction algorithms. Methods The scanners investigated were a newly installed Siemens Biograph mCT PET with 64-slice SOMATOM Definition AS CT using sinogram affirmed iterative reconstruction (SAFIRE) and two GE Discovery 710 PET scanners with 128-slice Optima 660 CT using adaptive statistical reconstruction (ASiR). Following exploratory phantom work, 33 adult patients of various sizes were scanned using the Siemens scanner and matched to patients scanned using our established GE protocol to give 33 patient pairs. A comparison of volumetric CT dose index (CTDIvol) and image noise within these patient pairs informed optimisation, specifically for obese patients. Another matched patient study containing 27 patient pairs was used to confirm protocol matching. Size-specific dose estimates (SSDEs) were calculated for patients in the second cohort. With the acquisition protocol for the Siemens scanner determined, clinicians visually graded the images to identify optimal reconstruction parameters. Results In the first matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 10.7% (range − 41.7 to 50.1%), and the mean percentage difference in noise measured in the patients’ liver was 7.6% (range − 31.0 to 76.8%). In the second matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 20.5% (range − 43.1 to 1.9%), and the mean percentage difference in noise was 19.8% (range − 27.0 to 146.8%). For these patients, the mean SSDEs for patients scanned on the Siemens and GE scanners were 3.27 (range 2.83 to 4.22) mGy and 4.09 (range 2.81 to 4.82) mGy, respectively. The analysis of the visual grading study indicated no preference for any of the SAFIRE strengths. Conclusions Given the different implementations of acquisition parameters and reconstruction algorithms between vendors, careful consideration is required to ensure optimisation and standardisation of protocols.
first_indexed 2024-12-19T20:52:45Z
format Article
id doaj.art-0ee91b8d7db846c3b56bf2a9297be89b
institution Directory Open Access Journal
issn 2197-7364
language English
last_indexed 2024-12-19T20:52:45Z
publishDate 2021-07-01
publisher SpringerOpen
record_format Article
series EJNMMI Physics
spelling doaj.art-0ee91b8d7db846c3b56bf2a9297be89b2022-12-21T20:06:03ZengSpringerOpenEJNMMI Physics2197-73642021-07-018111510.1186/s40658-021-00404-4Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithmsSarah-May Gould0Jane Mackewn1Sugama Chicklore2Gary J. R. Cook3Andrew Mallia4Lucy Pike5King’s College London & Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ HospitalKing’s College London & Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ HospitalKing’s College London & Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ HospitalKing’s College London & Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ HospitalKing’s College London & Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ HospitalKing’s College London & Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, St Thomas’ HospitalAbstract Background A significant proportion of the radiation dose from a PET-CT examination is dependent on the CT protocol, which should be optimised for clinical purposes. Matching protocols on different scanners within an imaging centre is important for the consistency of image quality and dose. This paper describes our experience translating low-dose CT protocols between scanner models utilising different automatic exposure control (AEC) methods and reconstruction algorithms. Methods The scanners investigated were a newly installed Siemens Biograph mCT PET with 64-slice SOMATOM Definition AS CT using sinogram affirmed iterative reconstruction (SAFIRE) and two GE Discovery 710 PET scanners with 128-slice Optima 660 CT using adaptive statistical reconstruction (ASiR). Following exploratory phantom work, 33 adult patients of various sizes were scanned using the Siemens scanner and matched to patients scanned using our established GE protocol to give 33 patient pairs. A comparison of volumetric CT dose index (CTDIvol) and image noise within these patient pairs informed optimisation, specifically for obese patients. Another matched patient study containing 27 patient pairs was used to confirm protocol matching. Size-specific dose estimates (SSDEs) were calculated for patients in the second cohort. With the acquisition protocol for the Siemens scanner determined, clinicians visually graded the images to identify optimal reconstruction parameters. Results In the first matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 10.7% (range − 41.7 to 50.1%), and the mean percentage difference in noise measured in the patients’ liver was 7.6% (range − 31.0 to 76.8%). In the second matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 20.5% (range − 43.1 to 1.9%), and the mean percentage difference in noise was 19.8% (range − 27.0 to 146.8%). For these patients, the mean SSDEs for patients scanned on the Siemens and GE scanners were 3.27 (range 2.83 to 4.22) mGy and 4.09 (range 2.81 to 4.82) mGy, respectively. The analysis of the visual grading study indicated no preference for any of the SAFIRE strengths. Conclusions Given the different implementations of acquisition parameters and reconstruction algorithms between vendors, careful consideration is required to ensure optimisation and standardisation of protocols.https://doi.org/10.1186/s40658-021-00404-4PET-CTAutomatic exposure controlOptimisationProtocol matchingIterative reconstruction
spellingShingle Sarah-May Gould
Jane Mackewn
Sugama Chicklore
Gary J. R. Cook
Andrew Mallia
Lucy Pike
Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
EJNMMI Physics
PET-CT
Automatic exposure control
Optimisation
Protocol matching
Iterative reconstruction
title Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
title_full Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
title_fullStr Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
title_full_unstemmed Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
title_short Optimisation of CT protocols in PET-CT across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
title_sort optimisation of ct protocols in pet ct across different scanner models using different automatic exposure control methods and iterative reconstruction algorithms
topic PET-CT
Automatic exposure control
Optimisation
Protocol matching
Iterative reconstruction
url https://doi.org/10.1186/s40658-021-00404-4
work_keys_str_mv AT sarahmaygould optimisationofctprotocolsinpetctacrossdifferentscannermodelsusingdifferentautomaticexposurecontrolmethodsanditerativereconstructionalgorithms
AT janemackewn optimisationofctprotocolsinpetctacrossdifferentscannermodelsusingdifferentautomaticexposurecontrolmethodsanditerativereconstructionalgorithms
AT sugamachicklore optimisationofctprotocolsinpetctacrossdifferentscannermodelsusingdifferentautomaticexposurecontrolmethodsanditerativereconstructionalgorithms
AT garyjrcook optimisationofctprotocolsinpetctacrossdifferentscannermodelsusingdifferentautomaticexposurecontrolmethodsanditerativereconstructionalgorithms
AT andrewmallia optimisationofctprotocolsinpetctacrossdifferentscannermodelsusingdifferentautomaticexposurecontrolmethodsanditerativereconstructionalgorithms
AT lucypike optimisationofctprotocolsinpetctacrossdifferentscannermodelsusingdifferentautomaticexposurecontrolmethodsanditerativereconstructionalgorithms