Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth
AIM: To compare the results of IOL Master, contact and immersion A-scan ultrasound measurements for anterior chamber depth(ACD), and evaluate the difference and consistency.<p>METHODS:Fifty-eight cases(98 eyes)with age-related cataract during July to October in 2013 did the A-scan ultrasound w...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2015-07-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://ies.ijo.cn/cn_publish/2015/7/201507039.pdf |
_version_ | 1818201253392416768 |
---|---|
author | Min Xu Rui-Zhen Ye Zhen-Zhen Chen |
author_facet | Min Xu Rui-Zhen Ye Zhen-Zhen Chen |
author_sort | Min Xu |
collection | DOAJ |
description | AIM: To compare the results of IOL Master, contact and immersion A-scan ultrasound measurements for anterior chamber depth(ACD), and evaluate the difference and consistency.<p>METHODS:Fifty-eight cases(98 eyes)with age-related cataract during July to October in 2013 did the A-scan ultrasound with contact and immersion measurements and IOL Master to get the results of ACD. Difference in measurements between methods was assessed using the variance analysisi. Consistency was assessed using Bland-Altman.<p>RESULTS: The ACD measured by IOL Master was 2.31~3.90mm, the mean was 3.03±0.38mm. The ACD measured by contact A-scan ultrasound was 1.51~4.06mm, the mean was 2.88±0.56mm. The ACD measured by immersion A-scan ultrasound was 1.99~4.17mm, the mean was 3.17±0.38mm. The results of IOL Master and contact A-scan ultrasound had statistical differences(<i>P</i>=0.022<0.05). The results of IOL Master and immersion A-scan ultrasound had statistical differences(<i>P</i>=0.031<0.05). The results of contact A-scan ultrasound and immersion A-scan ultrasound had statistical differences(<i>P</i>=0.000<0.05). The consistency between three methods was poor.<p>CONCLUSION: The rank of ACD of patients with cataract is immersion A-scan ultrasound, IOL Master and contact A-scan ultrasound. The consistency is poor, and the three methods can't be interchanged clinically. |
first_indexed | 2024-12-12T02:50:37Z |
format | Article |
id | doaj.art-0f08c24744fa40d9a734f202ff923ecc |
institution | Directory Open Access Journal |
issn | 1672-5123 1672-5123 |
language | English |
last_indexed | 2024-12-12T02:50:37Z |
publishDate | 2015-07-01 |
publisher | Press of International Journal of Ophthalmology (IJO PRESS) |
record_format | Article |
series | Guoji Yanke Zazhi |
spelling | doaj.art-0f08c24744fa40d9a734f202ff923ecc2022-12-22T00:40:54ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232015-07-011571253125510.3980/j.issn.1672-5123.2015.7.39Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depthMin Xu0Rui-Zhen Ye1Zhen-Zhen Chen2Department of Ophthalmology, the 180<sup>th</sup> Hospital of PLA, Quanzhou 362000, Fujian Province, ChinaDepartment of Ophthalmology, the 180<sup>th</sup> Hospital of PLA, Quanzhou 362000, Fujian Province, ChinaDepartment of Ophthalmology, the 180<sup>th</sup> Hospital of PLA, Quanzhou 362000, Fujian Province, ChinaAIM: To compare the results of IOL Master, contact and immersion A-scan ultrasound measurements for anterior chamber depth(ACD), and evaluate the difference and consistency.<p>METHODS:Fifty-eight cases(98 eyes)with age-related cataract during July to October in 2013 did the A-scan ultrasound with contact and immersion measurements and IOL Master to get the results of ACD. Difference in measurements between methods was assessed using the variance analysisi. Consistency was assessed using Bland-Altman.<p>RESULTS: The ACD measured by IOL Master was 2.31~3.90mm, the mean was 3.03±0.38mm. The ACD measured by contact A-scan ultrasound was 1.51~4.06mm, the mean was 2.88±0.56mm. The ACD measured by immersion A-scan ultrasound was 1.99~4.17mm, the mean was 3.17±0.38mm. The results of IOL Master and contact A-scan ultrasound had statistical differences(<i>P</i>=0.022<0.05). The results of IOL Master and immersion A-scan ultrasound had statistical differences(<i>P</i>=0.031<0.05). The results of contact A-scan ultrasound and immersion A-scan ultrasound had statistical differences(<i>P</i>=0.000<0.05). The consistency between three methods was poor.<p>CONCLUSION: The rank of ACD of patients with cataract is immersion A-scan ultrasound, IOL Master and contact A-scan ultrasound. The consistency is poor, and the three methods can't be interchanged clinically.http://ies.ijo.cn/cn_publish/2015/7/201507039.pdfcontactimmersionA-scan ultrasoundIOL Masteranterior chamber depthage-related cataract |
spellingShingle | Min Xu Rui-Zhen Ye Zhen-Zhen Chen Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth Guoji Yanke Zazhi contact immersion A-scan ultrasound IOL Master anterior chamber depth age-related cataract |
title | Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth |
title_full | Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth |
title_fullStr | Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth |
title_full_unstemmed | Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth |
title_short | Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth |
title_sort | comparison of iol master contact and immersion a scan ultrasound measurements of anterior chamber depth |
topic | contact immersion A-scan ultrasound IOL Master anterior chamber depth age-related cataract |
url | http://ies.ijo.cn/cn_publish/2015/7/201507039.pdf |
work_keys_str_mv | AT minxu comparisonofiolmastercontactandimmersionascanultrasoundmeasurementsofanteriorchamberdepth AT ruizhenye comparisonofiolmastercontactandimmersionascanultrasoundmeasurementsofanteriorchamberdepth AT zhenzhenchen comparisonofiolmastercontactandimmersionascanultrasoundmeasurementsofanteriorchamberdepth |