The personalized telemedical system of Obereg for remote patient's monitoring
The objective: to assess the potential use of the personalized telemedical system (PTS) of Obereg to ensure monitoring and constant medical control over the state of vital systems of the patient's body in the hospital, during transportation, and in out-of-hospital conditions.Subjects and method...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
New Terra Publishing House
2020-11-01
|
Series: | Вестник анестезиологии и реаниматологии |
Subjects: | |
Online Access: | https://www.vair-journal.com/jour/article/view/470 |
_version_ | 1797702746980220928 |
---|---|
author | A. A. Eremenko N. V. Rostunova S. A. Budagyan A. V. Kurnosov |
author_facet | A. A. Eremenko N. V. Rostunova S. A. Budagyan A. V. Kurnosov |
author_sort | A. A. Eremenko |
collection | DOAJ |
description | The objective: to assess the potential use of the personalized telemedical system (PTS) of Obereg to ensure monitoring and constant medical control over the state of vital systems of the patient's body in the hospital, during transportation, and in out-of-hospital conditions.Subjects and methods. The Obereg system was tested in leading Russian clinics through simultaneous measurement of vital activity parameters with other standard patient monitoring systems. Comparative evaluation criteria were the following: functionality, measurement accuracy in comparison with stationary systems, reliability of operation, the impact on the operation of PTS of other equipment in the intensive care unit and possible interference, user friendliness for personnel and patients, and verification of communication capabilities based on field experiments. Additional parameters of the system were also evaluated. The need for it by medical units of the Ministry of Health of Russia was estimated.Results. The operability of the system has been confirmed in clinical conditions for patients of various profiles, including the most severe cases; it was found that the functionality of the system and accuracy of measurement met relevant requirements. It was estimated that the total demand for such systems in Russia might amount to 4,250,000 units.Conclusion. The device can be used for individual and group monitoring in intensive care units, in in-patient settings after transfer from intensive care, during rehabilitation for remote monitoring at home, and during patients' transportation to monitor their condition in case of emergency. |
first_indexed | 2024-03-12T04:54:26Z |
format | Article |
id | doaj.art-0f238ae33bdf4ad98a9ac16bc23797b3 |
institution | Directory Open Access Journal |
issn | 2078-5658 2541-8653 |
language | Russian |
last_indexed | 2024-03-12T04:54:26Z |
publishDate | 2020-11-01 |
publisher | New Terra Publishing House |
record_format | Article |
series | Вестник анестезиологии и реаниматологии |
spelling | doaj.art-0f238ae33bdf4ad98a9ac16bc23797b32023-09-03T09:15:36ZrusNew Terra Publishing HouseВестник анестезиологии и реаниматологии2078-56582541-86532020-11-01175879410.21292/2078-5658-2020-17-5-87-94410The personalized telemedical system of Obereg for remote patient's monitoringA. A. Eremenko0N. V. Rostunova1S. A. Budagyan2A. V. Kurnosov3ФГБНУ «Российский научный центр хирургии им. акад. Б. В. Петровского»ФГБУ «Государственный научный центр Российской Федерации – Федеральный медицинский биофизический центр им. А. И. Бурназяна» Федерального медико-биологического агентства РоссииООО «УТК»ООО «УТК»The objective: to assess the potential use of the personalized telemedical system (PTS) of Obereg to ensure monitoring and constant medical control over the state of vital systems of the patient's body in the hospital, during transportation, and in out-of-hospital conditions.Subjects and methods. The Obereg system was tested in leading Russian clinics through simultaneous measurement of vital activity parameters with other standard patient monitoring systems. Comparative evaluation criteria were the following: functionality, measurement accuracy in comparison with stationary systems, reliability of operation, the impact on the operation of PTS of other equipment in the intensive care unit and possible interference, user friendliness for personnel and patients, and verification of communication capabilities based on field experiments. Additional parameters of the system were also evaluated. The need for it by medical units of the Ministry of Health of Russia was estimated.Results. The operability of the system has been confirmed in clinical conditions for patients of various profiles, including the most severe cases; it was found that the functionality of the system and accuracy of measurement met relevant requirements. It was estimated that the total demand for such systems in Russia might amount to 4,250,000 units.Conclusion. The device can be used for individual and group monitoring in intensive care units, in in-patient settings after transfer from intensive care, during rehabilitation for remote monitoring at home, and during patients' transportation to monitor their condition in case of emergency.https://www.vair-journal.com/jour/article/view/470телемедицинадистанционный мониторингносимый монитор пациента |
spellingShingle | A. A. Eremenko N. V. Rostunova S. A. Budagyan A. V. Kurnosov The personalized telemedical system of Obereg for remote patient's monitoring Вестник анестезиологии и реаниматологии телемедицина дистанционный мониторинг носимый монитор пациента |
title | The personalized telemedical system of Obereg for remote patient's monitoring |
title_full | The personalized telemedical system of Obereg for remote patient's monitoring |
title_fullStr | The personalized telemedical system of Obereg for remote patient's monitoring |
title_full_unstemmed | The personalized telemedical system of Obereg for remote patient's monitoring |
title_short | The personalized telemedical system of Obereg for remote patient's monitoring |
title_sort | personalized telemedical system of obereg for remote patient s monitoring |
topic | телемедицина дистанционный мониторинг носимый монитор пациента |
url | https://www.vair-journal.com/jour/article/view/470 |
work_keys_str_mv | AT aaeremenko thepersonalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT nvrostunova thepersonalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT sabudagyan thepersonalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT avkurnosov thepersonalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT aaeremenko personalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT nvrostunova personalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT sabudagyan personalizedtelemedicalsystemofoberegforremotepatientsmonitoring AT avkurnosov personalizedtelemedicalsystemofoberegforremotepatientsmonitoring |