Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)

Purpose. To present the preliminary results of iridocapsular fixation of RSP-3 extracapsular IOL in patients with lens subluxation observed within the first year after surgery.Material and methods. 4 patients with cataracts and initial weakness of Zinn ligament fibers were followed up. YAG laser iri...

Full description

Bibliographic Details
Main Authors: I. E. Ioshin, A. I. Tolchinskaya, S. A. Dubrovskaya
Format: Article
Language:Russian
Published: Real Time Ltd 2019-06-01
Series:Российский офтальмологический журнал
Subjects:
Online Access:https://roj.igb.ru/jour/article/view/268
_version_ 1797878338992209920
author I. E. Ioshin
A. I. Tolchinskaya
S. A. Dubrovskaya
author_facet I. E. Ioshin
A. I. Tolchinskaya
S. A. Dubrovskaya
author_sort I. E. Ioshin
collection DOAJ
description Purpose. To present the preliminary results of iridocapsular fixation of RSP-3 extracapsular IOL in patients with lens subluxation observed within the first year after surgery.Material and methods. 4 patients with cataracts and initial weakness of Zinn ligament fibers were followed up. YAG laser iridectomy was performed one day before facoemulsifcation surgery, which took account of Zinn ligament fiber weakness: it consisted in anterior continuous circular capsulorhexis with a diameter of about 5 mm, fixation of the capsular bag over the edge of capsulorhexis with four iris-capsular retractors (ICRs), phacoemulsification of the nucleus and aspiration of lens masses. The intracapsular ring and the RSP-3 IOL (the latter in the injector through the main incision) was implanted in such a way as to locate the rear support element in the capsular bag, and the front support element, in front of the pupil. After removing the ICRs, iridectomy was monitored.Results. The early postoperative period was uncomplicated. After 10 days, one patient was found to develop a relative pupillary block with the anterior chamber becoming shallower and IOP increased to reach 28 mm Hg. The reason was that iridectomy initially located in the projection area of the rear support element. An additional iridectomy arrested the situation. Visual acuity varied from 0.3 to 1.0 due to the initial state of the optic nerve and retina. The position of the IOL remained stable throughout the year, the capsular bag was unfolded.Conclusion. The possibility to use the capsular bag of the lens under the conditions that Zinn ligament fibers are weak should be considered as an advantage of the technology presented. An additional front support element serves to prevent dislocation of the IOL and the capsular bag as a whole. The obtained positive results of combined iridocapsular fixation of the IOL justify a more extensive clinical testing of the method in cases of weak Zinn ligament fibers.
first_indexed 2024-04-10T02:31:03Z
format Article
id doaj.art-0f92e7cbd9a14eb5a3e1c89df2c9bc7e
institution Directory Open Access Journal
issn 2072-0076
2587-5760
language Russian
last_indexed 2024-04-10T02:31:03Z
publishDate 2019-06-01
publisher Real Time Ltd
record_format Article
series Российский офтальмологический журнал
spelling doaj.art-0f92e7cbd9a14eb5a3e1c89df2c9bc7e2023-03-13T07:54:29ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602019-06-01122192510.21516/2072-0076-2019-12-2-19-25217Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)I. E. Ioshin0A. I. Tolchinskaya1S. A. Dubrovskaya2ФГБУ «Клиническая больница» Управделами Президента РФФГБУ «Клиническая больница» Управделами Президента РФФГБУ «ЦКБ с поликлиникой» Управделами Президента РФPurpose. To present the preliminary results of iridocapsular fixation of RSP-3 extracapsular IOL in patients with lens subluxation observed within the first year after surgery.Material and methods. 4 patients with cataracts and initial weakness of Zinn ligament fibers were followed up. YAG laser iridectomy was performed one day before facoemulsifcation surgery, which took account of Zinn ligament fiber weakness: it consisted in anterior continuous circular capsulorhexis with a diameter of about 5 mm, fixation of the capsular bag over the edge of capsulorhexis with four iris-capsular retractors (ICRs), phacoemulsification of the nucleus and aspiration of lens masses. The intracapsular ring and the RSP-3 IOL (the latter in the injector through the main incision) was implanted in such a way as to locate the rear support element in the capsular bag, and the front support element, in front of the pupil. After removing the ICRs, iridectomy was monitored.Results. The early postoperative period was uncomplicated. After 10 days, one patient was found to develop a relative pupillary block with the anterior chamber becoming shallower and IOP increased to reach 28 mm Hg. The reason was that iridectomy initially located in the projection area of the rear support element. An additional iridectomy arrested the situation. Visual acuity varied from 0.3 to 1.0 due to the initial state of the optic nerve and retina. The position of the IOL remained stable throughout the year, the capsular bag was unfolded.Conclusion. The possibility to use the capsular bag of the lens under the conditions that Zinn ligament fibers are weak should be considered as an advantage of the technology presented. An additional front support element serves to prevent dislocation of the IOL and the capsular bag as a whole. The obtained positive results of combined iridocapsular fixation of the IOL justify a more extensive clinical testing of the method in cases of weak Zinn ligament fibers.https://roj.igb.ru/jour/article/view/268слабость волокон цинновой связкифакоэмульсификациякомбинированная иридокапсулярная фиксация иол
spellingShingle I. E. Ioshin
A. I. Tolchinskaya
S. A. Dubrovskaya
Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)
Российский офтальмологический журнал
слабость волокон цинновой связки
факоэмульсификация
комбинированная иридокапсулярная фиксация иол
title Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)
title_full Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)
title_fullStr Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)
title_full_unstemmed Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)
title_short Failure iridocapsular fixation of IOL in patients with lens subluxation (preliminary report)
title_sort failure iridocapsular fixation of iol in patients with lens subluxation preliminary report
topic слабость волокон цинновой связки
факоэмульсификация
комбинированная иридокапсулярная фиксация иол
url https://roj.igb.ru/jour/article/view/268
work_keys_str_mv AT ieioshin failureiridocapsularfixationofiolinpatientswithlenssubluxationpreliminaryreport
AT aitolchinskaya failureiridocapsularfixationofiolinpatientswithlenssubluxationpreliminaryreport
AT sadubrovskaya failureiridocapsularfixationofiolinpatientswithlenssubluxationpreliminaryreport