Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits

ABSTRACT. Drago M.A., Drago M., Cerqueira H.D.B., Tiburcio M.F., Souza G.B., Barbosa D.H., Santos C.M.L., Silva R.V. & Freitas P.M.C. [Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits.] Avaliação ex vivo das propriedades mecânicas em flexão de p...

Full description

Bibliographic Details
Main Authors: Manuela Aleluia Drago, Mariana Drago, Hevila Dutra Barbosa de Cerqueira, Markson Freitas Tiburcio, Graziela Baroni Souza, Dinamara Honorato Barbosa, Christian Mariani Lucas dos Santos, Rosana Vilarim da Silva, Patricia Maria Coletto Freitas
Format: Article
Language:English
Published: Sociedade de Medicina Veterinária do Estado do Rio de Janeiro 2015-10-01
Series:Brazilian Journal of Veterinary Medicine
Online Access:http://rbmv.org/index.php/BJVM/article/view/390
_version_ 1818920553058140160
author Manuela Aleluia Drago
Mariana Drago
Hevila Dutra Barbosa de Cerqueira
Markson Freitas Tiburcio
Graziela Baroni Souza
Dinamara Honorato Barbosa
Christian Mariani Lucas dos Santos
Rosana Vilarim da Silva
Patricia Maria Coletto Freitas
author_facet Manuela Aleluia Drago
Mariana Drago
Hevila Dutra Barbosa de Cerqueira
Markson Freitas Tiburcio
Graziela Baroni Souza
Dinamara Honorato Barbosa
Christian Mariani Lucas dos Santos
Rosana Vilarim da Silva
Patricia Maria Coletto Freitas
author_sort Manuela Aleluia Drago
collection DOAJ
description ABSTRACT. Drago M.A., Drago M., Cerqueira H.D.B., Tiburcio M.F., Souza G.B., Barbosa D.H., Santos C.M.L., Silva R.V. & Freitas P.M.C. [Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits.] Avaliação ex vivo das propriedades mecânicas em flexão de placas ósseas bovina na osteossíntese de tíbias de coelhos. Revista Brasileira de Medicina Veterinária, 37(3):245-249, 2015. Programa de Pós-Graduação em Ciências Veterinárias, Universidade Federal do Espírito Santo (UFES), Alto Universitário, s/nº, Bairro Guararema, Alegre, ES 29500-000, Brasil. E-mail: manudrago@hotmail.com The use of materials produced from bovine bone has been proposed in the manufacture of implants such as pins, plates and screws, due to their osteoinductive and osteoconductive properties or functions of bone graft. However, structural and mechanical aspects must be evaluated prior to the use, in vivo of bone implants. The aim of this study was to evaluate mechanical strength, through a mechanical bending test, of plates produced from bovine cortical bone, used to repair fractures of the tíbia of rabbits ex vivo. Twenty six plates were manufactured from bovine cortical bone and stored in saturated salt solution. Three study groups were used: group GP (n = 10), made up of the bone plates; GTP group (n = 16), rabbit tibia osteotomized and stabilized with bone plates and four screws and Group GT (n = 10), intact tibia. A three-point bending biomechanical test was used to determine the maximum tension, maximum deflection, and stiffness. The results were submitted to Kruskal-Wallis test (p <0.05) and the Dunn test. Comparing GT with the GTP, an 80% reduction was observed in maximum tension. Also noted was a reduction of 87% in maximum tension when comparing GP with GTP. Therefore, the bovine bone plate had a higher maximum tension then the intact rabbit tibia. There was a reduction of 52% in the rigidity of GTP to GT. No significant difference was observed between this force when GPT and GP were compared. There was significant difference among the three groups with respect to maximum deflection, which showed an increase of 100% and 30% in the GTP and GP groups, respectively, when compared to the GT. This study, therefore concluded, that bone plates used to repair fractures of the tibia of rabbits ex vivo presented inferior mechanical properties when compared to intact tibia.
first_indexed 2024-12-20T01:23:35Z
format Article
id doaj.art-103945be48e9401a8e9c89aa43ec643a
institution Directory Open Access Journal
issn 0100-2430
2527-2179
language English
last_indexed 2024-12-20T01:23:35Z
publishDate 2015-10-01
publisher Sociedade de Medicina Veterinária do Estado do Rio de Janeiro
record_format Article
series Brazilian Journal of Veterinary Medicine
spelling doaj.art-103945be48e9401a8e9c89aa43ec643a2022-12-21T19:58:19ZengSociedade de Medicina Veterinária do Estado do Rio de JaneiroBrazilian Journal of Veterinary Medicine0100-24302527-21792015-10-01373245249390Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbitsManuela Aleluia DragoMariana DragoHevila Dutra Barbosa de CerqueiraMarkson Freitas TiburcioGraziela Baroni SouzaDinamara Honorato BarbosaChristian Mariani Lucas dos SantosRosana Vilarim da SilvaPatricia Maria Coletto FreitasABSTRACT. Drago M.A., Drago M., Cerqueira H.D.B., Tiburcio M.F., Souza G.B., Barbosa D.H., Santos C.M.L., Silva R.V. & Freitas P.M.C. [Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits.] Avaliação ex vivo das propriedades mecânicas em flexão de placas ósseas bovina na osteossíntese de tíbias de coelhos. Revista Brasileira de Medicina Veterinária, 37(3):245-249, 2015. Programa de Pós-Graduação em Ciências Veterinárias, Universidade Federal do Espírito Santo (UFES), Alto Universitário, s/nº, Bairro Guararema, Alegre, ES 29500-000, Brasil. E-mail: manudrago@hotmail.com The use of materials produced from bovine bone has been proposed in the manufacture of implants such as pins, plates and screws, due to their osteoinductive and osteoconductive properties or functions of bone graft. However, structural and mechanical aspects must be evaluated prior to the use, in vivo of bone implants. The aim of this study was to evaluate mechanical strength, through a mechanical bending test, of plates produced from bovine cortical bone, used to repair fractures of the tíbia of rabbits ex vivo. Twenty six plates were manufactured from bovine cortical bone and stored in saturated salt solution. Three study groups were used: group GP (n = 10), made up of the bone plates; GTP group (n = 16), rabbit tibia osteotomized and stabilized with bone plates and four screws and Group GT (n = 10), intact tibia. A three-point bending biomechanical test was used to determine the maximum tension, maximum deflection, and stiffness. The results were submitted to Kruskal-Wallis test (p <0.05) and the Dunn test. Comparing GT with the GTP, an 80% reduction was observed in maximum tension. Also noted was a reduction of 87% in maximum tension when comparing GP with GTP. Therefore, the bovine bone plate had a higher maximum tension then the intact rabbit tibia. There was a reduction of 52% in the rigidity of GTP to GT. No significant difference was observed between this force when GPT and GP were compared. There was significant difference among the three groups with respect to maximum deflection, which showed an increase of 100% and 30% in the GTP and GP groups, respectively, when compared to the GT. This study, therefore concluded, that bone plates used to repair fractures of the tibia of rabbits ex vivo presented inferior mechanical properties when compared to intact tibia.http://rbmv.org/index.php/BJVM/article/view/390
spellingShingle Manuela Aleluia Drago
Mariana Drago
Hevila Dutra Barbosa de Cerqueira
Markson Freitas Tiburcio
Graziela Baroni Souza
Dinamara Honorato Barbosa
Christian Mariani Lucas dos Santos
Rosana Vilarim da Silva
Patricia Maria Coletto Freitas
Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
Brazilian Journal of Veterinary Medicine
title Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
title_full Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
title_fullStr Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
title_full_unstemmed Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
title_short Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
title_sort ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits
url http://rbmv.org/index.php/BJVM/article/view/390
work_keys_str_mv AT manuelaaleluiadrago exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT marianadrago exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT heviladutrabarbosadecerqueira exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT marksonfreitastiburcio exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT grazielabaronisouza exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT dinamarahonoratobarbosa exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT christianmarianilucasdossantos exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT rosanavilarimdasilva exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits
AT patriciamariacolettofreitas exvivoflexuralmechanicalpropertiesofbovineboneplatesaftertibiaeosteosynthesisinrabbits