Parametric Study of the Corrosion of API-5L-X65 QT Steel Using Potentiostat Based Measurements in a Flow Loop
Low-carbon steel is widely used in industrial pipelines, and corrosion studies are focused mostly on erosion-corrosion, its prediction and control. In this paper, the corrosion rate in pipelines is modeled using a flow loop and measured by linear polarization resistance method (LPR) using a 3-electr...
Main Authors: | Arjun Ravikumar, Paul Rostron, Nader Vahdati, Oleg Shiryayev |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-01-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/11/1/444 |
Similar Items
-
Effect of Magnetic Field on the Corrosion of API-5L-X65 Steel Using Electrochemical Methods in a Flow Loop
by: Shahid Parapurath, et al.
Published: (2021-10-01) -
External corrosion detection of oil pipelines using fiber optics
by: Vahdati, Nader, et al.
Published: (2021) -
Detection of Internal Metal Loss in Steel Pipes and Storage Tanks via Magnetic-Based Fiber Optic Sensor
by: Safieh Almahmoud, et al.
Published: (2018-03-01) -
External Corrosion Detection of Oil Pipelines Using Fiber Optics
by: Nader Vahdati, et al.
Published: (2020-01-01) -
Corrosivity Sensor for Exposed Pipelines Based on Wireless Energy Transfer
by: Lydia Lawand, et al.
Published: (2017-05-01)