Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.

To examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake ([Formula: see text]) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP).Twenty recreationally active individuals (14 mal...

Full description

Bibliographic Details
Main Authors: Michael J Hutchinson, Thomas A W Paulson, Roger Eston, Victoria L Goosey-Tolfrey
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2017-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5509239?pdf=render
_version_ 1819087095750197248
author Michael J Hutchinson
Thomas A W Paulson
Roger Eston
Victoria L Goosey-Tolfrey
author_facet Michael J Hutchinson
Thomas A W Paulson
Roger Eston
Victoria L Goosey-Tolfrey
author_sort Michael J Hutchinson
collection DOAJ
description To examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake ([Formula: see text]) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP).Twenty recreationally active individuals (14 male, 6 female) completed four trials across a 2-week period, using a randomised, counterbalanced design. Participants completed two RAMP protocols (20 W·min-1) in week 1, followed by two PRETmax in week 2, or vice versa. The PRETmax comprised five, 2-min stages clamped at Ratings of Perceived Exertion (RPE) 11, 13, 15, 17 and 20. Participants changed power output (PO) as often as required to maintain target RPE. Gas exchange variables (oxygen uptake, carbon dioxide production, minute ventilation), heart rate (HR) and PO were collected throughout. Differentiated RPE were collected at the end of each stage throughout trials.For relative [Formula: see text], coefficient of variation (CV) was equal to 4.1% and 4.8%, with ICC(3,1) of 0.92 and 0.85 for repeated measures from PRETmax and RAMP, respectively. Measurement error was 0.15 L·min-1 and 2.11 ml·kg-1·min-1 in PRETmax and 0.16 L·min-1 and 2.29 ml·kg-1·min-1 during RAMP for determining absolute and relative [Formula: see text], respectively. The difference in [Formula: see text] between PRETmax and RAMP was tending towards statistical significance (26.2 ± 5.1 versus 24.3 ± 4.0 ml·kg-1·min-1, P = 0.055). The 95% LoA were -1.9 ± 4.1 (-9.9 to 6.2) ml·kg-1·min-1.The PRETmax can be used as a reliable test to measure [Formula: see text] during handcycle exercise in recreationally active participants. Whilst PRETmax tended towards significantly greater [Formula: see text] values than RAMP, the difference is smaller than measurement error of determining [Formula: see text] from PRETmax and RAMP.
first_indexed 2024-12-21T21:30:42Z
format Article
id doaj.art-112c363fdd9e4325befb78264952df78
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-21T21:30:42Z
publishDate 2017-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-112c363fdd9e4325befb78264952df782022-12-21T18:49:38ZengPublic Library of Science (PLoS)PLoS ONE1932-62032017-01-01127e018100810.1371/journal.pone.0181008Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.Michael J HutchinsonThomas A W PaulsonRoger EstonVictoria L Goosey-TolfreyTo examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake ([Formula: see text]) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP).Twenty recreationally active individuals (14 male, 6 female) completed four trials across a 2-week period, using a randomised, counterbalanced design. Participants completed two RAMP protocols (20 W·min-1) in week 1, followed by two PRETmax in week 2, or vice versa. The PRETmax comprised five, 2-min stages clamped at Ratings of Perceived Exertion (RPE) 11, 13, 15, 17 and 20. Participants changed power output (PO) as often as required to maintain target RPE. Gas exchange variables (oxygen uptake, carbon dioxide production, minute ventilation), heart rate (HR) and PO were collected throughout. Differentiated RPE were collected at the end of each stage throughout trials.For relative [Formula: see text], coefficient of variation (CV) was equal to 4.1% and 4.8%, with ICC(3,1) of 0.92 and 0.85 for repeated measures from PRETmax and RAMP, respectively. Measurement error was 0.15 L·min-1 and 2.11 ml·kg-1·min-1 in PRETmax and 0.16 L·min-1 and 2.29 ml·kg-1·min-1 during RAMP for determining absolute and relative [Formula: see text], respectively. The difference in [Formula: see text] between PRETmax and RAMP was tending towards statistical significance (26.2 ± 5.1 versus 24.3 ± 4.0 ml·kg-1·min-1, P = 0.055). The 95% LoA were -1.9 ± 4.1 (-9.9 to 6.2) ml·kg-1·min-1.The PRETmax can be used as a reliable test to measure [Formula: see text] during handcycle exercise in recreationally active participants. Whilst PRETmax tended towards significantly greater [Formula: see text] values than RAMP, the difference is smaller than measurement error of determining [Formula: see text] from PRETmax and RAMP.http://europepmc.org/articles/PMC5509239?pdf=render
spellingShingle Michael J Hutchinson
Thomas A W Paulson
Roger Eston
Victoria L Goosey-Tolfrey
Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.
PLoS ONE
title Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.
title_full Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.
title_fullStr Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.
title_full_unstemmed Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.
title_short Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.
title_sort assessment of peak oxygen uptake during handcycling test retest reliability and comparison of a ramp incremented and perceptually regulated exercise test
url http://europepmc.org/articles/PMC5509239?pdf=render
work_keys_str_mv AT michaeljhutchinson assessmentofpeakoxygenuptakeduringhandcyclingtestretestreliabilityandcomparisonofarampincrementedandperceptuallyregulatedexercisetest
AT thomasawpaulson assessmentofpeakoxygenuptakeduringhandcyclingtestretestreliabilityandcomparisonofarampincrementedandperceptuallyregulatedexercisetest
AT rogereston assessmentofpeakoxygenuptakeduringhandcyclingtestretestreliabilityandcomparisonofarampincrementedandperceptuallyregulatedexercisetest
AT victorialgooseytolfrey assessmentofpeakoxygenuptakeduringhandcyclingtestretestreliabilityandcomparisonofarampincrementedandperceptuallyregulatedexercisetest