ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY
Aim: The accuracy of three electronic apex locators (EALs) during retreatment of root-end resected teeth with different resection bevel angles were evaluated in the present study. Materials and Methods: Forty mandibular premolar teeth were divided into two groups regarding resection bevel angle aft...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Cumhuriyet University
2022-06-01
|
Series: | Cumhuriyet Dental Journal |
Subjects: | |
Online Access: | https://dergipark.org.tr/tr/download/article-file/2374836 |
_version_ | 1827832311911022592 |
---|---|
author | Demet Altunbaş Fatma Kaya Kerem Engin Akpınar |
author_facet | Demet Altunbaş Fatma Kaya Kerem Engin Akpınar |
author_sort | Demet Altunbaş |
collection | DOAJ |
description | Aim: The accuracy of three electronic apex locators (EALs) during retreatment of root-end resected teeth with different resection bevel angles were evaluated in the present study.
Materials and Methods: Forty mandibular premolar teeth were divided into two groups regarding resection bevel angle after root canal filling. In the first group, the apical 3 mm of each specimen was resected at a 0-degree bevel angle using a diamond bur. The resection bevel angle was approximately 45-degree in the second group. Electronic length measurements were obtained with a size 15 K-file advanced apically in dissolved gutta percha using Dentaport ZX, Propex Pixi, and Apit 15. The filling materials were then completely removed from the root canals, and the actual lengths up to the resection region were determined. The actual length was subtracted from the electronic length measurements for each specimen. Measurements were analyzed statistically using independent sample t-test, repeated-measures analysis of variance, and Bonferroni tests. The level of statistical significance was defined as P<0.05.
Results: In the 45-degree group, a significant difference was found between Propex Pixi and Apit 15. Measurements at 0- and 45-degree resection bevel angles were not statistically different from each other in any EAL groups.
Conclusions: The resection bevel angle did not affect the accuracy of the tested EALs. More accurate measurements were obtained with the Propex Pixi at a 45-degree resection bevel angle compared with the Apit 15. |
first_indexed | 2024-03-12T05:09:22Z |
format | Article |
id | doaj.art-119ff84633094dc3ab32eef056ccada3 |
institution | Directory Open Access Journal |
issn | 1302-5805 2146-2852 |
language | English |
last_indexed | 2024-03-12T05:09:22Z |
publishDate | 2022-06-01 |
publisher | Cumhuriyet University |
record_format | Article |
series | Cumhuriyet Dental Journal |
spelling | doaj.art-119ff84633094dc3ab32eef056ccada32023-09-03T08:42:01ZengCumhuriyet UniversityCumhuriyet Dental Journal1302-58052146-28522022-06-0125213714110.7126/cumudj.11036062057ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDYDemet Altunbaş0Fatma Kaya1Kerem Engin Akpınar2CUMHURIYET UNIVERSITY, FACULTY OF DENTISTRYKayseri Private Uzmandent Dental HospitalSIVAS CUMHURIYET UNIVERSITY, FACULTY OF DENTISTRYAim: The accuracy of three electronic apex locators (EALs) during retreatment of root-end resected teeth with different resection bevel angles were evaluated in the present study. Materials and Methods: Forty mandibular premolar teeth were divided into two groups regarding resection bevel angle after root canal filling. In the first group, the apical 3 mm of each specimen was resected at a 0-degree bevel angle using a diamond bur. The resection bevel angle was approximately 45-degree in the second group. Electronic length measurements were obtained with a size 15 K-file advanced apically in dissolved gutta percha using Dentaport ZX, Propex Pixi, and Apit 15. The filling materials were then completely removed from the root canals, and the actual lengths up to the resection region were determined. The actual length was subtracted from the electronic length measurements for each specimen. Measurements were analyzed statistically using independent sample t-test, repeated-measures analysis of variance, and Bonferroni tests. The level of statistical significance was defined as P<0.05. Results: In the 45-degree group, a significant difference was found between Propex Pixi and Apit 15. Measurements at 0- and 45-degree resection bevel angles were not statistically different from each other in any EAL groups. Conclusions: The resection bevel angle did not affect the accuracy of the tested EALs. More accurate measurements were obtained with the Propex Pixi at a 45-degree resection bevel angle compared with the Apit 15.https://dergipark.org.tr/tr/download/article-file/2374836elektronik apeks bulucurezeksiyon eğim açısıyeniden tedavikök kanalı.electronic apex locatorresection bevel angleretreatmentroot canal. |
spellingShingle | Demet Altunbaş Fatma Kaya Kerem Engin Akpınar ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY Cumhuriyet Dental Journal elektronik apeks bulucu rezeksiyon eğim açısı yeniden tedavi kök kanalı. electronic apex locator resection bevel angle retreatment root canal. |
title | ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY |
title_full | ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY |
title_fullStr | ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY |
title_full_unstemmed | ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY |
title_short | ACCURACY OF 3 ELECTRONIC APEX LOCATORS IN NONSURGICAL RETREATMENTS OF TEETH WITH ROOT-ENDS RESECTED AT DIFFERENT ANGLES: IN-VITRO STUDY |
title_sort | accuracy of 3 electronic apex locators in nonsurgical retreatments of teeth with root ends resected at different angles in vitro study |
topic | elektronik apeks bulucu rezeksiyon eğim açısı yeniden tedavi kök kanalı. electronic apex locator resection bevel angle retreatment root canal. |
url | https://dergipark.org.tr/tr/download/article-file/2374836 |
work_keys_str_mv | AT demetaltunbas accuracyof3electronicapexlocatorsinnonsurgicalretreatmentsofteethwithrootendsresectedatdifferentanglesinvitrostudy AT fatmakaya accuracyof3electronicapexlocatorsinnonsurgicalretreatmentsofteethwithrootendsresectedatdifferentanglesinvitrostudy AT keremenginakpınar accuracyof3electronicapexlocatorsinnonsurgicalretreatmentsofteethwithrootendsresectedatdifferentanglesinvitrostudy |