Robustness of the combined arch system with radial ties
To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem o...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2023-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/26/e3sconf_uesf2023_01053.pdf |
_version_ | 1797807899007778816 |
---|---|
author | Dolgusheva Vera Ibragimov Alexander Dolgushev Timothey |
author_facet | Dolgusheva Vera Ibragimov Alexander Dolgushev Timothey |
author_sort | Dolgusheva Vera |
collection | DOAJ |
description | To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem of girders bridging in public buildings, but the robustness of these systems is poorly studied. This article presents the results of the failure analysis of the coating elements in the form of combined steel arches with radial ties under various failure scenarios, the robustness of the n-th level in a static formulation is investigated, considering the geometrically nonlinear nature of the system operation, constructive measures are proposed to increase the robustness of a combined arch system with radial ties. The calculations were performed in the SCAD Office software 21.1.9.11. For the considered fragment of the scheme in both scenarios, the robustness index Irob > 98.5% corresponds to the local nature of the excess of the load-carrying ability, Irob ≤ 98.5% - to disproportional. As soon as the asymmetric prestressing of the arch by ties disappears, which occurs when the most loaded ties are turned off step by step, the system either satisfies the strength and stability tests, or the number of elements in which the load-carrying ability is exceeded significantly decreases. Increasing the structural integrity of the structure by introducing chordal ties into the scheme contributes to increasing the robustness of the considered arch system. |
first_indexed | 2024-03-13T06:29:31Z |
format | Article |
id | doaj.art-11cac593049b4e48b1567885fd1ba404 |
institution | Directory Open Access Journal |
issn | 2267-1242 |
language | English |
last_indexed | 2024-03-13T06:29:31Z |
publishDate | 2023-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | E3S Web of Conferences |
spelling | doaj.art-11cac593049b4e48b1567885fd1ba4042023-06-09T09:08:58ZengEDP SciencesE3S Web of Conferences2267-12422023-01-013890105310.1051/e3sconf/202338901053e3sconf_uesf2023_01053Robustness of the combined arch system with radial tiesDolgusheva Vera0Ibragimov Alexander1Dolgushev Timothey2National Research University Moscow State University of Civil Engineering (NRU MGSU)National Research University Moscow State University of Civil Engineering (NRU MGSU)National Research University Moscow State University of Civil Engineering (NRU MGSU)To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem of girders bridging in public buildings, but the robustness of these systems is poorly studied. This article presents the results of the failure analysis of the coating elements in the form of combined steel arches with radial ties under various failure scenarios, the robustness of the n-th level in a static formulation is investigated, considering the geometrically nonlinear nature of the system operation, constructive measures are proposed to increase the robustness of a combined arch system with radial ties. The calculations were performed in the SCAD Office software 21.1.9.11. For the considered fragment of the scheme in both scenarios, the robustness index Irob > 98.5% corresponds to the local nature of the excess of the load-carrying ability, Irob ≤ 98.5% - to disproportional. As soon as the asymmetric prestressing of the arch by ties disappears, which occurs when the most loaded ties are turned off step by step, the system either satisfies the strength and stability tests, or the number of elements in which the load-carrying ability is exceeded significantly decreases. Increasing the structural integrity of the structure by introducing chordal ties into the scheme contributes to increasing the robustness of the considered arch system.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/26/e3sconf_uesf2023_01053.pdf |
spellingShingle | Dolgusheva Vera Ibragimov Alexander Dolgushev Timothey Robustness of the combined arch system with radial ties E3S Web of Conferences |
title | Robustness of the combined arch system with radial ties |
title_full | Robustness of the combined arch system with radial ties |
title_fullStr | Robustness of the combined arch system with radial ties |
title_full_unstemmed | Robustness of the combined arch system with radial ties |
title_short | Robustness of the combined arch system with radial ties |
title_sort | robustness of the combined arch system with radial ties |
url | https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/26/e3sconf_uesf2023_01053.pdf |
work_keys_str_mv | AT dolgushevavera robustnessofthecombinedarchsystemwithradialties AT ibragimovalexander robustnessofthecombinedarchsystemwithradialties AT dolgushevtimothey robustnessofthecombinedarchsystemwithradialties |