Robustness of the combined arch system with radial ties

To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem o...

Full description

Bibliographic Details
Main Authors: Dolgusheva Vera, Ibragimov Alexander, Dolgushev Timothey
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/26/e3sconf_uesf2023_01053.pdf
_version_ 1797807899007778816
author Dolgusheva Vera
Ibragimov Alexander
Dolgushev Timothey
author_facet Dolgusheva Vera
Ibragimov Alexander
Dolgushev Timothey
author_sort Dolgusheva Vera
collection DOAJ
description To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem of girders bridging in public buildings, but the robustness of these systems is poorly studied. This article presents the results of the failure analysis of the coating elements in the form of combined steel arches with radial ties under various failure scenarios, the robustness of the n-th level in a static formulation is investigated, considering the geometrically nonlinear nature of the system operation, constructive measures are proposed to increase the robustness of a combined arch system with radial ties. The calculations were performed in the SCAD Office software 21.1.9.11. For the considered fragment of the scheme in both scenarios, the robustness index Irob > 98.5% corresponds to the local nature of the excess of the load-carrying ability, Irob ≤ 98.5% - to disproportional. As soon as the asymmetric prestressing of the arch by ties disappears, which occurs when the most loaded ties are turned off step by step, the system either satisfies the strength and stability tests, or the number of elements in which the load-carrying ability is exceeded significantly decreases. Increasing the structural integrity of the structure by introducing chordal ties into the scheme contributes to increasing the robustness of the considered arch system.
first_indexed 2024-03-13T06:29:31Z
format Article
id doaj.art-11cac593049b4e48b1567885fd1ba404
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-03-13T06:29:31Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-11cac593049b4e48b1567885fd1ba4042023-06-09T09:08:58ZengEDP SciencesE3S Web of Conferences2267-12422023-01-013890105310.1051/e3sconf/202338901053e3sconf_uesf2023_01053Robustness of the combined arch system with radial tiesDolgusheva Vera0Ibragimov Alexander1Dolgushev Timothey2National Research University Moscow State University of Civil Engineering (NRU MGSU)National Research University Moscow State University of Civil Engineering (NRU MGSU)National Research University Moscow State University of Civil Engineering (NRU MGSU)To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem of girders bridging in public buildings, but the robustness of these systems is poorly studied. This article presents the results of the failure analysis of the coating elements in the form of combined steel arches with radial ties under various failure scenarios, the robustness of the n-th level in a static formulation is investigated, considering the geometrically nonlinear nature of the system operation, constructive measures are proposed to increase the robustness of a combined arch system with radial ties. The calculations were performed in the SCAD Office software 21.1.9.11. For the considered fragment of the scheme in both scenarios, the robustness index Irob > 98.5% corresponds to the local nature of the excess of the load-carrying ability, Irob ≤ 98.5% - to disproportional. As soon as the asymmetric prestressing of the arch by ties disappears, which occurs when the most loaded ties are turned off step by step, the system either satisfies the strength and stability tests, or the number of elements in which the load-carrying ability is exceeded significantly decreases. Increasing the structural integrity of the structure by introducing chordal ties into the scheme contributes to increasing the robustness of the considered arch system.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/26/e3sconf_uesf2023_01053.pdf
spellingShingle Dolgusheva Vera
Ibragimov Alexander
Dolgushev Timothey
Robustness of the combined arch system with radial ties
E3S Web of Conferences
title Robustness of the combined arch system with radial ties
title_full Robustness of the combined arch system with radial ties
title_fullStr Robustness of the combined arch system with radial ties
title_full_unstemmed Robustness of the combined arch system with radial ties
title_short Robustness of the combined arch system with radial ties
title_sort robustness of the combined arch system with radial ties
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/26/e3sconf_uesf2023_01053.pdf
work_keys_str_mv AT dolgushevavera robustnessofthecombinedarchsystemwithradialties
AT ibragimovalexander robustnessofthecombinedarchsystemwithradialties
AT dolgushevtimothey robustnessofthecombinedarchsystemwithradialties