Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty

Compared with conventional penetrating keratoplasty, Descemet's stripping automated endothelial keratoplasty (DSAEK) more effectively maintain global integrity and rapid vision rehabilitation with less ocular surface disorders in patients with endothelial dysfunction. Here, we report a case of...

Full description

Bibliographic Details
Main Authors: Meng-Sheng Lee, I-Lun Tsai, Ching-Yao Tsai, Li-Lin Kuo, Shiow-Wen Liou, Lin-Chung Woung
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:Taiwan Journal of Ophthalmology
Subjects:
Online Access:http://www.e-tjo.org/article.asp?issn=2211-5056;year=2017;volume=7;issue=3;spage=160;epage=163;aulast=Lee
_version_ 1818900529300897792
author Meng-Sheng Lee
I-Lun Tsai
Ching-Yao Tsai
Li-Lin Kuo
Shiow-Wen Liou
Lin-Chung Woung
author_facet Meng-Sheng Lee
I-Lun Tsai
Ching-Yao Tsai
Li-Lin Kuo
Shiow-Wen Liou
Lin-Chung Woung
author_sort Meng-Sheng Lee
collection DOAJ
description Compared with conventional penetrating keratoplasty, Descemet's stripping automated endothelial keratoplasty (DSAEK) more effectively maintain global integrity and rapid vision rehabilitation with less ocular surface disorders in patients with endothelial dysfunction. Here, we report a case of a 76-year-old woman who experienced opacification of a hydrophilic intraocular lens (IOL) approximately 10 months after DSAEK. The patient with no history of systemic disease developed pseudophakic bullous keratopathy in the right eye 2 years after undergoing cataract surgery. The best-corrected visual acuity (BCVA) of the right eye was Snellen 0.01 when presented to our hospital. DSAEK was arranged and performed smoothly. However, the graft detached over the upper part of the cornea on postoperative day 1. Thus, rebubbling was performed immediately. After the procedure, the graft was well attached, and the cornea became clear gradually. The BCVA returned to Snellen 0.6. However, progressive opacification over the anterior surface of the IOL was observed 10 months postoperatively. Vision deteriorated to 0.5 with various refractive errors during 2-year follow-up. IOL exchange may be considered if the vision is getting worse. IOL opacification may result from a direct contact between the IOL surface and exogenous air, particularly in a hydrophilic IOL, and can be a rare but significant complication after DSAEK. Clinicians planning to perform DSAEK should consider the composition of the IOL, the amount of intracameral air, duration of air filling, and high intraocular pressure.
first_indexed 2024-12-19T20:05:18Z
format Article
id doaj.art-12369be6d06f4bafb225f721ed008bd4
institution Directory Open Access Journal
issn 2211-5056
2211-5072
language English
last_indexed 2024-12-19T20:05:18Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Taiwan Journal of Ophthalmology
spelling doaj.art-12369be6d06f4bafb225f721ed008bd42022-12-21T20:07:31ZengWolters Kluwer Medknow PublicationsTaiwan Journal of Ophthalmology2211-50562211-50722017-01-017316016310.4103/tjo.tjo_54_17Intraocular lens opacification after Descemet's stripping automated endothelial keratoplastyMeng-Sheng LeeI-Lun TsaiChing-Yao TsaiLi-Lin KuoShiow-Wen LiouLin-Chung WoungCompared with conventional penetrating keratoplasty, Descemet's stripping automated endothelial keratoplasty (DSAEK) more effectively maintain global integrity and rapid vision rehabilitation with less ocular surface disorders in patients with endothelial dysfunction. Here, we report a case of a 76-year-old woman who experienced opacification of a hydrophilic intraocular lens (IOL) approximately 10 months after DSAEK. The patient with no history of systemic disease developed pseudophakic bullous keratopathy in the right eye 2 years after undergoing cataract surgery. The best-corrected visual acuity (BCVA) of the right eye was Snellen 0.01 when presented to our hospital. DSAEK was arranged and performed smoothly. However, the graft detached over the upper part of the cornea on postoperative day 1. Thus, rebubbling was performed immediately. After the procedure, the graft was well attached, and the cornea became clear gradually. The BCVA returned to Snellen 0.6. However, progressive opacification over the anterior surface of the IOL was observed 10 months postoperatively. Vision deteriorated to 0.5 with various refractive errors during 2-year follow-up. IOL exchange may be considered if the vision is getting worse. IOL opacification may result from a direct contact between the IOL surface and exogenous air, particularly in a hydrophilic IOL, and can be a rare but significant complication after DSAEK. Clinicians planning to perform DSAEK should consider the composition of the IOL, the amount of intracameral air, duration of air filling, and high intraocular pressure.http://www.e-tjo.org/article.asp?issn=2211-5056;year=2017;volume=7;issue=3;spage=160;epage=163;aulast=LeeDescemet's stripping automated endothelial keratoplastyhydrophilic intraocular lensintracameral airopacification
spellingShingle Meng-Sheng Lee
I-Lun Tsai
Ching-Yao Tsai
Li-Lin Kuo
Shiow-Wen Liou
Lin-Chung Woung
Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty
Taiwan Journal of Ophthalmology
Descemet's stripping automated endothelial keratoplasty
hydrophilic intraocular lens
intracameral air
opacification
title Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty
title_full Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty
title_fullStr Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty
title_full_unstemmed Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty
title_short Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty
title_sort intraocular lens opacification after descemet s stripping automated endothelial keratoplasty
topic Descemet's stripping automated endothelial keratoplasty
hydrophilic intraocular lens
intracameral air
opacification
url http://www.e-tjo.org/article.asp?issn=2211-5056;year=2017;volume=7;issue=3;spage=160;epage=163;aulast=Lee
work_keys_str_mv AT mengshenglee intraocularlensopacificationafterdescemetsstrippingautomatedendothelialkeratoplasty
AT iluntsai intraocularlensopacificationafterdescemetsstrippingautomatedendothelialkeratoplasty
AT chingyaotsai intraocularlensopacificationafterdescemetsstrippingautomatedendothelialkeratoplasty
AT lilinkuo intraocularlensopacificationafterdescemetsstrippingautomatedendothelialkeratoplasty
AT shiowwenliou intraocularlensopacificationafterdescemetsstrippingautomatedendothelialkeratoplasty
AT linchungwoung intraocularlensopacificationafterdescemetsstrippingautomatedendothelialkeratoplasty