A study on stabilization of operation time for hydraulic operating circuit breaker (Stability of hydraulic operation stabilizing system holding constant high pressure)

Stability of a hydraulic operation stabilization system during valve returning motion was investigated by the measurement and numerical analysis of the hydraulic circuit. Inadequate selection of hydraulic circuit constants causes the returning motion unstable and valves repeat open-close motion peri...

Full description

Bibliographic Details
Main Authors: Tohru YAMASHITA, Nobuya NAKAJIMA, Yoshiki HIRANO, Tsutomu SUGIYAMA, Toshiaki YOSHIZUMI
Format: Article
Language:Japanese
Published: The Japan Society of Mechanical Engineers 2016-01-01
Series:Nihon Kikai Gakkai ronbunshu
Subjects:
Online Access:https://www.jstage.jst.go.jp/article/transjsme/82/834/82_15-00432/_pdf/-char/en
Description
Summary:Stability of a hydraulic operation stabilization system during valve returning motion was investigated by the measurement and numerical analysis of the hydraulic circuit. Inadequate selection of hydraulic circuit constants causes the returning motion unstable and valves repeat open-close motion periodically. Hydraulic circuit constants related to the valve returning motion were set as parameter and analyzed. The volume of the back space of a discharge valve which is connected with hydraulic return circuit is important on the motion stability, and hydraulic vibration occurs by the combination of the volume with other hydraulic circuit constants. The reach of the constants which influence the motion stability was considered. The small volume and proper selection of other hydraulic circuit constants make a hydraulic operation stabilizing system stable.
ISSN:2187-9761