Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
The accuracy of isotopic compositions measurement is affected by all the ICP-MS instruments because of the phenomenon known as mass bias, where it is defined as difference between the measured and true values in an isotopic analysis. This research has introduced mass bias and also evaluated the effe...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Nuclear Science and Technology Research Institute
2014-11-01
|
Series: | مجله علوم و فنون هستهای |
Subjects: | |
Online Access: | https://jonsat.nstri.ir/article_46_9e401cbca78e4b17dc694ca0d6f94682.pdf |
_version_ | 1797835072365133824 |
---|---|
author | Javad Yazdani Masoud Agha Hosseini Mohammadreza Rezvanianzadeh Rasoul Sayari |
author_facet | Javad Yazdani Masoud Agha Hosseini Mohammadreza Rezvanianzadeh Rasoul Sayari |
author_sort | Javad Yazdani |
collection | DOAJ |
description | The accuracy of isotopic compositions measurement is affected by all the ICP-MS instruments because of the phenomenon known as mass bias, where it is defined as difference between the measured and true values in an isotopic analysis. This research has introduced mass bias and also evaluated the effective parameters including concentration of uranium, electrical field behind the second or skimmer cone, detector voltage, plasma power and nebulizer flow. The least mass bias with a relative error -0.3% for the isotopic analysis of uranium results in aqueous media without interference of the matrix with 1.2% RSD of 0.3 mg/L concentration, while the voltages of ion lens 1 and 2 in the ICP-TOF-MS were -700V and -550V, respectively. The instrument was set in the plasma power of 1000 watts, nebulizer flow of 0.78 ml/min, and the detector voltage of -2450V. |
first_indexed | 2024-04-09T14:47:24Z |
format | Article |
id | doaj.art-130649150f454f4e9a5a7f937b1b5b9a |
institution | Directory Open Access Journal |
issn | 1735-1871 2676-5861 |
language | fas |
last_indexed | 2024-04-09T14:47:24Z |
publishDate | 2014-11-01 |
publisher | Nuclear Science and Technology Research Institute |
record_format | Article |
series | مجله علوم و فنون هستهای |
spelling | doaj.art-130649150f454f4e9a5a7f937b1b5b9a2023-05-02T10:30:49ZfasNuclear Science and Technology Research Instituteمجله علوم و فنون هستهای1735-18712676-58612014-11-01353687546Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MSJavad Yazdani0Masoud Agha Hosseini1Mohammadreza Rezvanianzadeh2Rasoul Sayari3شرکت سوخت رآکتورهای هسته ای، صندوق پستی: 43551-14376، اصفهان ـ ایرانشرکت سوخت رآکتورهای هسته ای، صندوق پستی: 43551-14376، اصفهان ـ ایرانپژوهشکده ی چرخه ی سوخت هسته ای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران، صندوق پستی: 8486-11365، تهران ـ ایرانشرکت سوخت رآکتورهای هسته ای، صندوق پستی: 43551-14376، اصفهان ـ ایرانThe accuracy of isotopic compositions measurement is affected by all the ICP-MS instruments because of the phenomenon known as mass bias, where it is defined as difference between the measured and true values in an isotopic analysis. This research has introduced mass bias and also evaluated the effective parameters including concentration of uranium, electrical field behind the second or skimmer cone, detector voltage, plasma power and nebulizer flow. The least mass bias with a relative error -0.3% for the isotopic analysis of uranium results in aqueous media without interference of the matrix with 1.2% RSD of 0.3 mg/L concentration, while the voltages of ion lens 1 and 2 in the ICP-TOF-MS were -700V and -550V, respectively. The instrument was set in the plasma power of 1000 watts, nebulizer flow of 0.78 ml/min, and the detector voltage of -2450V.https://jonsat.nstri.ir/article_46_9e401cbca78e4b17dc694ca0d6f94682.pdfmass biasicp-tof-msisotopic analysis |
spellingShingle | Javad Yazdani Masoud Agha Hosseini Mohammadreza Rezvanianzadeh Rasoul Sayari Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS مجله علوم و فنون هستهای mass bias icp-tof-ms isotopic analysis |
title | Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS |
title_full | Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS |
title_fullStr | Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS |
title_full_unstemmed | Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS |
title_short | Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS |
title_sort | evaluation of effective parameters in mass bias for increase of accuracy in isotopic analysis of uranium by icp tof ms |
topic | mass bias icp-tof-ms isotopic analysis |
url | https://jonsat.nstri.ir/article_46_9e401cbca78e4b17dc694ca0d6f94682.pdf |
work_keys_str_mv | AT javadyazdani evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms AT masoudaghahosseini evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms AT mohammadrezarezvanianzadeh evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms AT rasoulsayari evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms |