Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS

The accuracy of isotopic compositions measurement is affected by all the ICP-MS instruments because of the phenomenon known as mass bias, where it is defined as difference between the measured and true values in an isotopic analysis. This research has introduced mass bias and also evaluated the effe...

Full description

Bibliographic Details
Main Authors: Javad Yazdani, Masoud Agha Hosseini, Mohammadreza Rezvanianzadeh, Rasoul Sayari
Format: Article
Language:fas
Published: Nuclear Science and Technology Research Institute 2014-11-01
Series:مجله علوم و فنون هسته‌ای
Subjects:
Online Access:https://jonsat.nstri.ir/article_46_9e401cbca78e4b17dc694ca0d6f94682.pdf
_version_ 1797835072365133824
author Javad Yazdani
Masoud Agha Hosseini
Mohammadreza Rezvanianzadeh
Rasoul Sayari
author_facet Javad Yazdani
Masoud Agha Hosseini
Mohammadreza Rezvanianzadeh
Rasoul Sayari
author_sort Javad Yazdani
collection DOAJ
description The accuracy of isotopic compositions measurement is affected by all the ICP-MS instruments because of the phenomenon known as mass bias, where it is defined as difference between the measured and true values in an isotopic analysis. This research has introduced mass bias and also evaluated the effective parameters including concentration of uranium, electrical field behind the second or skimmer cone, detector voltage, plasma power and nebulizer flow. The least mass bias with a relative error -0.3% for the isotopic analysis of uranium results in aqueous media without interference of the matrix with 1.2% RSD of 0.3 mg/L concentration, while the voltages of ion lens 1 and 2 in the ICP-TOF-MS were -700V and -550V, respectively. The instrument was set in the plasma power of 1000 watts, nebulizer flow of 0.78 ml/min, and the detector voltage of -2450V.
first_indexed 2024-04-09T14:47:24Z
format Article
id doaj.art-130649150f454f4e9a5a7f937b1b5b9a
institution Directory Open Access Journal
issn 1735-1871
2676-5861
language fas
last_indexed 2024-04-09T14:47:24Z
publishDate 2014-11-01
publisher Nuclear Science and Technology Research Institute
record_format Article
series مجله علوم و فنون هسته‌ای
spelling doaj.art-130649150f454f4e9a5a7f937b1b5b9a2023-05-02T10:30:49ZfasNuclear Science and Technology Research Instituteمجله علوم و فنون هسته‌ای1735-18712676-58612014-11-01353687546Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MSJavad Yazdani0Masoud Agha Hosseini1Mohammadreza Rezvanianzadeh2Rasoul Sayari3شرکت سوخت رآکتورهای هسته ای، صندوق پستی: 43551-14376، اصفهان ـ ایرانشرکت سوخت رآکتورهای هسته ای، صندوق پستی: 43551-14376، اصفهان ـ ایرانپژوهشکده ی چرخه ی سوخت هسته ای، پژوهشگاه علوم و فنون هسته‌ای، سازمان انرژی اتمی ایران، صندوق پستی: 8486-11365، تهران ـ ایرانشرکت سوخت رآکتورهای هسته ای، صندوق پستی: 43551-14376، اصفهان ـ ایرانThe accuracy of isotopic compositions measurement is affected by all the ICP-MS instruments because of the phenomenon known as mass bias, where it is defined as difference between the measured and true values in an isotopic analysis. This research has introduced mass bias and also evaluated the effective parameters including concentration of uranium, electrical field behind the second or skimmer cone, detector voltage, plasma power and nebulizer flow. The least mass bias with a relative error -0.3% for the isotopic analysis of uranium results in aqueous media without interference of the matrix with 1.2% RSD of 0.3 mg/L concentration, while the voltages of ion lens 1 and 2 in the ICP-TOF-MS were -700V and -550V, respectively. The instrument was set in the plasma power of 1000 watts, nebulizer flow of 0.78 ml/min, and the detector voltage of -2450V.https://jonsat.nstri.ir/article_46_9e401cbca78e4b17dc694ca0d6f94682.pdfmass biasicp-tof-msisotopic analysis
spellingShingle Javad Yazdani
Masoud Agha Hosseini
Mohammadreza Rezvanianzadeh
Rasoul Sayari
Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
مجله علوم و فنون هسته‌ای
mass bias
icp-tof-ms
isotopic analysis
title Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
title_full Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
title_fullStr Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
title_full_unstemmed Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
title_short Evaluation of Effective Parameters in Mass Bias for Increase of Accuracy in Isotopic Analysis of Uranium by ICP-TOF-MS
title_sort evaluation of effective parameters in mass bias for increase of accuracy in isotopic analysis of uranium by icp tof ms
topic mass bias
icp-tof-ms
isotopic analysis
url https://jonsat.nstri.ir/article_46_9e401cbca78e4b17dc694ca0d6f94682.pdf
work_keys_str_mv AT javadyazdani evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms
AT masoudaghahosseini evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms
AT mohammadrezarezvanianzadeh evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms
AT rasoulsayari evaluationofeffectiveparametersinmassbiasforincreaseofaccuracyinisotopicanalysisofuraniumbyicptofms