Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation

Förster Resonance Energy Transfer (FRET) enables the observation of interactions at the nanoscale level through the use of fluorescence optical imaging techniques. In FRET, fluorescence lifetime imaging can be used to quantify the fluorescence lifetime changes of the donor molecule, which are associ...

Full description

Bibliographic Details
Main Authors: Sez-Jade Chen, Nattawut Sinsuebphon, Xavier Intes
Format: Article
Language:English
Published: MDPI AG 2015-09-01
Series:Photonics
Subjects:
Online Access:http://www.mdpi.com/2304-6732/2/4/1027
_version_ 1831632207120171008
author Sez-Jade Chen
Nattawut Sinsuebphon
Xavier Intes
author_facet Sez-Jade Chen
Nattawut Sinsuebphon
Xavier Intes
author_sort Sez-Jade Chen
collection DOAJ
description Förster Resonance Energy Transfer (FRET) enables the observation of interactions at the nanoscale level through the use of fluorescence optical imaging techniques. In FRET, fluorescence lifetime imaging can be used to quantify the fluorescence lifetime changes of the donor molecule, which are associated with proximity between acceptor and donor molecules. Among the FRET parameters derived from fluorescence lifetime imaging, the percentage of donor that interacts with the acceptor (in proximity) can be estimated via model-based fitting. However, estimation of the lifetime parameters can be affected by the acquisition parameters such as the temporal characteristics of the imaging system. Herein, we investigate the effect of various gate widths on the accuracy of estimation of FRET parameters with focus on the near-infrared spectral window. Experiments were performed in silico, in vitro, and in vivo with gate width sizes ranging from 300 ps to 1000 ps in intervals of 100 ps. For all cases, the FRET parameters were retrieved accurately and the imaging acquisition time was decreased three-fold. These results indicate that increasing the gate width up to 1000 ps still allows for accurate quantification of FRET interactions even in the case of short lifetimes such as those encountered with near-infrared FRET pairs.
first_indexed 2024-12-19T05:14:52Z
format Article
id doaj.art-132af7d48d7f4283b629bc40cdb449ab
institution Directory Open Access Journal
issn 2304-6732
language English
last_indexed 2024-12-19T05:14:52Z
publishDate 2015-09-01
publisher MDPI AG
record_format Article
series Photonics
spelling doaj.art-132af7d48d7f4283b629bc40cdb449ab2022-12-21T20:34:42ZengMDPI AGPhotonics2304-67322015-09-01241027104210.3390/photonics2041027photonics2041027Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter EstimationSez-Jade Chen0Nattawut Sinsuebphon1Xavier Intes2Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180, USADepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180, USADepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180, USAFörster Resonance Energy Transfer (FRET) enables the observation of interactions at the nanoscale level through the use of fluorescence optical imaging techniques. In FRET, fluorescence lifetime imaging can be used to quantify the fluorescence lifetime changes of the donor molecule, which are associated with proximity between acceptor and donor molecules. Among the FRET parameters derived from fluorescence lifetime imaging, the percentage of donor that interacts with the acceptor (in proximity) can be estimated via model-based fitting. However, estimation of the lifetime parameters can be affected by the acquisition parameters such as the temporal characteristics of the imaging system. Herein, we investigate the effect of various gate widths on the accuracy of estimation of FRET parameters with focus on the near-infrared spectral window. Experiments were performed in silico, in vitro, and in vivo with gate width sizes ranging from 300 ps to 1000 ps in intervals of 100 ps. For all cases, the FRET parameters were retrieved accurately and the imaging acquisition time was decreased three-fold. These results indicate that increasing the gate width up to 1000 ps still allows for accurate quantification of FRET interactions even in the case of short lifetimes such as those encountered with near-infrared FRET pairs.http://www.mdpi.com/2304-6732/2/4/1027Förster Resonance Energy Transfer (FRET)time-resolved imaginggate widthfluorescence lifetimegated ICCDnear infrared (NIR) dyes in vivo imaging
spellingShingle Sez-Jade Chen
Nattawut Sinsuebphon
Xavier Intes
Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
Photonics
Förster Resonance Energy Transfer (FRET)
time-resolved imaging
gate width
fluorescence lifetime
gated ICCD
near infrared (NIR) dyes
in vivo imaging
title Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
title_full Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
title_fullStr Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
title_full_unstemmed Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
title_short Assessment of Gate Width Size on Lifetime-Based Förster Resonance Energy Transfer Parameter Estimation
title_sort assessment of gate width size on lifetime based forster resonance energy transfer parameter estimation
topic Förster Resonance Energy Transfer (FRET)
time-resolved imaging
gate width
fluorescence lifetime
gated ICCD
near infrared (NIR) dyes
in vivo imaging
url http://www.mdpi.com/2304-6732/2/4/1027
work_keys_str_mv AT sezjadechen assessmentofgatewidthsizeonlifetimebasedforsterresonanceenergytransferparameterestimation
AT nattawutsinsuebphon assessmentofgatewidthsizeonlifetimebasedforsterresonanceenergytransferparameterestimation
AT xavierintes assessmentofgatewidthsizeonlifetimebasedforsterresonanceenergytransferparameterestimation