Radiological performance of hot water layer system in open pool type reactor
The paper presents the calculated dose rate carried out by using MicroShield code to show the importance of hot water layer system (HWL) in 22 MW open pool type reactor from the radiation protection safety point of view. The paper presents the dose rate profiles over the pool surface in normal and a...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2013-06-01
|
Series: | Alexandria Engineering Journal |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1110016813000070 |
_version_ | 1818673010318508032 |
---|---|
author | Amr Abdelhady |
author_facet | Amr Abdelhady |
author_sort | Amr Abdelhady |
collection | DOAJ |
description | The paper presents the calculated dose rate carried out by using MicroShield code to show the importance of hot water layer system (HWL) in 22 MW open pool type reactor from the radiation protection safety point of view. The paper presents the dose rate profiles over the pool surface in normal and abnormal operations of HWL system. The results show that, in case of losing the hot water layer effect, the radiation dose rate profiles over the pool surface will increase from values lower than the worker permissible dose limits to values very higher than the permissible dose limits. |
first_indexed | 2024-12-17T07:48:59Z |
format | Article |
id | doaj.art-1393a60a45e34075b5bc7625bce62a1b |
institution | Directory Open Access Journal |
issn | 1110-0168 |
language | English |
last_indexed | 2024-12-17T07:48:59Z |
publishDate | 2013-06-01 |
publisher | Elsevier |
record_format | Article |
series | Alexandria Engineering Journal |
spelling | doaj.art-1393a60a45e34075b5bc7625bce62a1b2022-12-21T21:57:55ZengElsevierAlexandria Engineering Journal1110-01682013-06-0152215916210.1016/j.aej.2012.12.008Radiological performance of hot water layer system in open pool type reactorAmr AbdelhadyThe paper presents the calculated dose rate carried out by using MicroShield code to show the importance of hot water layer system (HWL) in 22 MW open pool type reactor from the radiation protection safety point of view. The paper presents the dose rate profiles over the pool surface in normal and abnormal operations of HWL system. The results show that, in case of losing the hot water layer effect, the radiation dose rate profiles over the pool surface will increase from values lower than the worker permissible dose limits to values very higher than the permissible dose limits.http://www.sciencedirect.com/science/article/pii/S1110016813000070Radiation dose calculationRadiological hazardOpen pool research reactorRadioprotection |
spellingShingle | Amr Abdelhady Radiological performance of hot water layer system in open pool type reactor Alexandria Engineering Journal Radiation dose calculation Radiological hazard Open pool research reactor Radioprotection |
title | Radiological performance of hot water layer system in open pool type reactor |
title_full | Radiological performance of hot water layer system in open pool type reactor |
title_fullStr | Radiological performance of hot water layer system in open pool type reactor |
title_full_unstemmed | Radiological performance of hot water layer system in open pool type reactor |
title_short | Radiological performance of hot water layer system in open pool type reactor |
title_sort | radiological performance of hot water layer system in open pool type reactor |
topic | Radiation dose calculation Radiological hazard Open pool research reactor Radioprotection |
url | http://www.sciencedirect.com/science/article/pii/S1110016813000070 |
work_keys_str_mv | AT amrabdelhady radiologicalperformanceofhotwaterlayersysteminopenpooltypereactor |