Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy

Objectives: Orthopedic implants have improved the quality of life in aging society but also induces several kinds of tissue reactions, referred to as orthopedic implant hypersensitivity (OIH). The aim of our study is to report the clinical characteristics of OIH and the effects of photobiomodulation...

Full description

Bibliographic Details
Main Authors: Ro-Wei Wu, Chung-Hsing Chang
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2023-01-01
Series:Tzu-Chi Medical Journal
Subjects:
Online Access:http://www.tcmjmed.com/article.asp?issn=1016-3190;year=2023;volume=35;issue=2;spage=176;epage=181;aulast=Wu
_version_ 1797775334941130752
author Ro-Wei Wu
Chung-Hsing Chang
author_facet Ro-Wei Wu
Chung-Hsing Chang
author_sort Ro-Wei Wu
collection DOAJ
description Objectives: Orthopedic implants have improved the quality of life in aging society but also induces several kinds of tissue reactions, referred to as orthopedic implant hypersensitivity (OIH). The aim of our study is to report the clinical characteristics of OIH and the effects of photobiomodulation therapy (PBMT) on these groups of patients. Materials and Methods: We collected cases that complained of skin rashes with pruritus after orthopedic implants from January 2017 to June 2022 at the Dermatology clinic in Hualien Tzu Chi Hospital. We recorded the sites and material of orthopedic implants, skin lesions onset time, symptoms, location after implantation, and the disease duration. Laboratory tests were measured, including complete blood count, differential count, serum immunoglobulin E (IgE) level, as well as inflammatory and autoimmune markers. PBMT, including UVB311 nm or low-level laser therapy 808 nm, was performed. Dose, duration, and response were documented. Results: Fourteen patients were diagnosed with OIH; twelve presented with localized eczema at the implant sites, and two with generalized eczema. Eleven patients (78.6%) had either elevated eosinophils percentage (>6%) or IgE level (>200 U/mL) or both. Seven patients (50%) had favorable outcome after PBMT and successfully withdrew from systemic steroid. Conclusion: In our case series, localized eczema at implant sites was a common cutaneous presentation in OIH. Hence, a surgical scar at the eczema site or long-term waxing and waning generalized eczema should prompt physicians on the possibility of OIH. Blood eosinophils percentage and serum IgE level can be reference biomarkers for OIH. PBMT provides a noninvasive and effective treatment strategy for immune regulation and tissue regeneration.
first_indexed 2024-03-12T22:34:12Z
format Article
id doaj.art-140b496ebdb34916bf98d217757c4bd3
institution Directory Open Access Journal
issn 1016-3190
2223-8956
language English
last_indexed 2024-03-12T22:34:12Z
publishDate 2023-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Tzu-Chi Medical Journal
spelling doaj.art-140b496ebdb34916bf98d217757c4bd32023-07-21T13:08:21ZengWolters Kluwer Medknow PublicationsTzu-Chi Medical Journal1016-31902223-89562023-01-0135217618110.4103/tcmj.tcmj_255_22Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapyRo-Wei WuChung-Hsing ChangObjectives: Orthopedic implants have improved the quality of life in aging society but also induces several kinds of tissue reactions, referred to as orthopedic implant hypersensitivity (OIH). The aim of our study is to report the clinical characteristics of OIH and the effects of photobiomodulation therapy (PBMT) on these groups of patients. Materials and Methods: We collected cases that complained of skin rashes with pruritus after orthopedic implants from January 2017 to June 2022 at the Dermatology clinic in Hualien Tzu Chi Hospital. We recorded the sites and material of orthopedic implants, skin lesions onset time, symptoms, location after implantation, and the disease duration. Laboratory tests were measured, including complete blood count, differential count, serum immunoglobulin E (IgE) level, as well as inflammatory and autoimmune markers. PBMT, including UVB311 nm or low-level laser therapy 808 nm, was performed. Dose, duration, and response were documented. Results: Fourteen patients were diagnosed with OIH; twelve presented with localized eczema at the implant sites, and two with generalized eczema. Eleven patients (78.6%) had either elevated eosinophils percentage (>6%) or IgE level (>200 U/mL) or both. Seven patients (50%) had favorable outcome after PBMT and successfully withdrew from systemic steroid. Conclusion: In our case series, localized eczema at implant sites was a common cutaneous presentation in OIH. Hence, a surgical scar at the eczema site or long-term waxing and waning generalized eczema should prompt physicians on the possibility of OIH. Blood eosinophils percentage and serum IgE level can be reference biomarkers for OIH. PBMT provides a noninvasive and effective treatment strategy for immune regulation and tissue regeneration.http://www.tcmjmed.com/article.asp?issn=1016-3190;year=2023;volume=35;issue=2;spage=176;epage=181;aulast=Wuagedeczemahypersensitivityorthopedic implantphotobiomodulation therapy
spellingShingle Ro-Wei Wu
Chung-Hsing Chang
Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
Tzu-Chi Medical Journal
aged
eczema
hypersensitivity
orthopedic implant
photobiomodulation therapy
title Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_full Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_fullStr Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_full_unstemmed Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_short Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_sort orthopedic implant hypersensitivity characterization of clinical presentation and effects of photobiomodulation therapy
topic aged
eczema
hypersensitivity
orthopedic implant
photobiomodulation therapy
url http://www.tcmjmed.com/article.asp?issn=1016-3190;year=2023;volume=35;issue=2;spage=176;epage=181;aulast=Wu
work_keys_str_mv AT roweiwu orthopedicimplanthypersensitivitycharacterizationofclinicalpresentationandeffectsofphotobiomodulationtherapy
AT chunghsingchang orthopedicimplanthypersensitivitycharacterizationofclinicalpresentationandeffectsofphotobiomodulationtherapy