Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces
Aim: To evaluate the adhesion of mouse bone marrow mesenchymal cells (MBMMC) on different titanium surfaces. Methods: Grade II titanium discs (ASTM F86) received two different surface treatments: polished (S1) and cathodic cage plasma nitriding (S2). MBMMC were cultured on titanium discs in 24-well...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Estadual de Campinas
2015-11-01
|
Series: | Brazilian Journal of Oral Sciences |
Subjects: | |
Online Access: | https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641611 |
_version_ | 1818858979540860928 |
---|---|
author | Luciana Bastos Alves Fernanda Ginani José Sandro Pereira da Silva Carlos Augusto Galvão Barboza Clodomiro Alves Junior |
author_facet | Luciana Bastos Alves Fernanda Ginani José Sandro Pereira da Silva Carlos Augusto Galvão Barboza Clodomiro Alves Junior |
author_sort | Luciana Bastos Alves |
collection | DOAJ |
description | Aim: To evaluate the adhesion of mouse bone marrow mesenchymal cells (MBMMC) on different titanium surfaces. Methods: Grade II titanium discs (ASTM F86) received two different surface treatments: polished (S1) and cathodic cage plasma nitriding (S2). MBMMC were cultured on titanium discs in 24-well cell culture plates, at a density of 1 x 104 cells per well. After 24 h, the adhesion was evaluated using a hemocytometer. Results: The mean adhesion was greater on S2, though without statistically significant difference from S2 (p>0.05). Conclusions: It was demonstrated that titanium surface treatment with ionic nitriding in a cathodic cage is biocompatible since it preserved the integrity of the cultivated MBMMC for a period of 24 h, allowing their adhesion. |
first_indexed | 2024-12-19T09:04:53Z |
format | Article |
id | doaj.art-140cafe2e5b549829a23de1101d6b258 |
institution | Directory Open Access Journal |
issn | 1677-3225 |
language | English |
last_indexed | 2024-12-19T09:04:53Z |
publishDate | 2015-11-01 |
publisher | Universidade Estadual de Campinas |
record_format | Article |
series | Brazilian Journal of Oral Sciences |
spelling | doaj.art-140cafe2e5b549829a23de1101d6b2582022-12-21T20:28:23ZengUniversidade Estadual de CampinasBrazilian Journal of Oral Sciences1677-32252015-11-0110410.20396/bjos.v10i4.8641611Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfacesLuciana Bastos Alves0Fernanda Ginani1José Sandro Pereira da Silva2Carlos Augusto Galvão Barboza3Clodomiro Alves Junior4Federal University of Rio Grande do NorteFederal University of Rio Grande do NorteFederal University of Rio Grande do NorteFederal University of Rio Grande do NorteFederal University of Rio Grande do NorteAim: To evaluate the adhesion of mouse bone marrow mesenchymal cells (MBMMC) on different titanium surfaces. Methods: Grade II titanium discs (ASTM F86) received two different surface treatments: polished (S1) and cathodic cage plasma nitriding (S2). MBMMC were cultured on titanium discs in 24-well cell culture plates, at a density of 1 x 104 cells per well. After 24 h, the adhesion was evaluated using a hemocytometer. Results: The mean adhesion was greater on S2, though without statistically significant difference from S2 (p>0.05). Conclusions: It was demonstrated that titanium surface treatment with ionic nitriding in a cathodic cage is biocompatible since it preserved the integrity of the cultivated MBMMC for a period of 24 h, allowing their adhesion.https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641611Mesenchymal stem cellsBone marrowTitanium |
spellingShingle | Luciana Bastos Alves Fernanda Ginani José Sandro Pereira da Silva Carlos Augusto Galvão Barboza Clodomiro Alves Junior Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces Brazilian Journal of Oral Sciences Mesenchymal stem cells Bone marrow Titanium |
title | Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces |
title_full | Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces |
title_fullStr | Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces |
title_full_unstemmed | Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces |
title_short | Bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces |
title_sort | bone marrow mesenchymal cell adhesion to polished and nitrided titanium surfaces |
topic | Mesenchymal stem cells Bone marrow Titanium |
url | https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641611 |
work_keys_str_mv | AT lucianabastosalves bonemarrowmesenchymalcelladhesiontopolishedandnitridedtitaniumsurfaces AT fernandaginani bonemarrowmesenchymalcelladhesiontopolishedandnitridedtitaniumsurfaces AT josesandropereiradasilva bonemarrowmesenchymalcelladhesiontopolishedandnitridedtitaniumsurfaces AT carlosaugustogalvaobarboza bonemarrowmesenchymalcelladhesiontopolishedandnitridedtitaniumsurfaces AT clodomiroalvesjunior bonemarrowmesenchymalcelladhesiontopolishedandnitridedtitaniumsurfaces |