Analysis of superheater tubes failure
Failures of boiler pressure parts, which working in high temperature and pressure conditions are often caused by overheating or corrosion. These two parameters are decisive, but not the only ones. Local stress concentration also depends on the type of headers support and external loads from pipeline...
Main Authors: | Felkowski Łukasz, Mędrala Jakub |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/08/e3sconf_icbt2018_01002.pdf |
Similar Items
-
Analysis of Superheater Work Under Creep Conditions
by: Piotr Duda, et al.
Published: (2015-03-01) -
High-Temperature Graphitization Failure of Primary Superheater Tube
by: Ghosh D., et al.
Published: (2015-12-01) - Steel boiler and superheater tubes
-
Failure analysis of a superheater tube of a coal-fired power plant
by: Reis Piedade, Salustiano Dos
Published: (2008) -
Failure analysis of a superheater tube of a coal-fired power plant
by: Piedade, Salustiano Dos Reis
Published: (2008)