Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique

Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is perfo...

Full description

Bibliographic Details
Main Authors: Sanketh Kethireddy, Keerthi Kethireddy
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:The Journal of Indian Prosthodontic Society
Subjects:
Online Access:http://www.j-ips.org/article.asp?issn=0972-4052;year=2017;volume=17;issue=3;spage=310;epage=315;aulast=Kethireddy
_version_ 1818056465940742144
author Sanketh Kethireddy
Keerthi Kethireddy
author_facet Sanketh Kethireddy
Keerthi Kethireddy
author_sort Sanketh Kethireddy
collection DOAJ
description Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is performed without removing it. Therefore, an attachment level impression method is utilized for the refabrication of a new prosthesis on an existing Hader bar framework without removing it from the patient's defect. This case report discusses a modification of the Mahidol University technique. This modification provides a simple, speedy, and convenient method through which the relation between the metal framework and attachments could be obtained precisely. This precision allowed for easy fabrication of the acrylic housing, which in turn results in better adaptation of the auricular prosthesis to the patient's face. Therefore, this technique offers advantages to both the prosthetist in fabrication and the patient in facilitating him continue to wear his existing implant-retained prosthesis during refabrication process.
first_indexed 2024-12-10T12:29:17Z
format Article
id doaj.art-142765d244424586b520bf9b26f8b792
institution Directory Open Access Journal
issn 0972-4052
1998-4057
language English
last_indexed 2024-12-10T12:29:17Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series The Journal of Indian Prosthodontic Society
spelling doaj.art-142765d244424586b520bf9b26f8b7922022-12-22T01:48:51ZengWolters Kluwer Medknow PublicationsThe Journal of Indian Prosthodontic Society0972-40521998-40572017-01-0117331031510.4103/jips.jips_227_16Refabrication of an implant-retained auricular prosthesis using clip attachment pickup techniqueSanketh KethireddyKeerthi KethireddyIncreased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is performed without removing it. Therefore, an attachment level impression method is utilized for the refabrication of a new prosthesis on an existing Hader bar framework without removing it from the patient's defect. This case report discusses a modification of the Mahidol University technique. This modification provides a simple, speedy, and convenient method through which the relation between the metal framework and attachments could be obtained precisely. This precision allowed for easy fabrication of the acrylic housing, which in turn results in better adaptation of the auricular prosthesis to the patient's face. Therefore, this technique offers advantages to both the prosthetist in fabrication and the patient in facilitating him continue to wear his existing implant-retained prosthesis during refabrication process.http://www.j-ips.org/article.asp?issn=0972-4052;year=2017;volume=17;issue=3;spage=310;epage=315;aulast=KethireddyAttachment level impressioncraniofacial implantsimplant retentionindirect acrylic housingsilicone auricular prosthesis
spellingShingle Sanketh Kethireddy
Keerthi Kethireddy
Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
The Journal of Indian Prosthodontic Society
Attachment level impression
craniofacial implants
implant retention
indirect acrylic housing
silicone auricular prosthesis
title Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_full Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_fullStr Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_full_unstemmed Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_short Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_sort refabrication of an implant retained auricular prosthesis using clip attachment pickup technique
topic Attachment level impression
craniofacial implants
implant retention
indirect acrylic housing
silicone auricular prosthesis
url http://www.j-ips.org/article.asp?issn=0972-4052;year=2017;volume=17;issue=3;spage=310;epage=315;aulast=Kethireddy
work_keys_str_mv AT sankethkethireddy refabricationofanimplantretainedauricularprosthesisusingclipattachmentpickuptechnique
AT keerthikethireddy refabricationofanimplantretainedauricularprosthesisusingclipattachmentpickuptechnique