A simplified passive islanding detection technique based on susceptible power indice with zero NDZ
Distributed energy resources (DER’s) incorporation in power system brings economical, technical and environmental benefits. Besides these benefits, excess penetration of DER’s elevates technical concerns. Islanding detection is one of main issue and is essential for personnel safety and protection o...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022-06-01
|
Series: | Ain Shams Engineering Journal |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2090447921004135 |
_version_ | 1817999639547215872 |
---|---|
author | Nouman Shafique Safdar Raza Sumayya Bibi Muhammad Farhan Mughees Riaz |
author_facet | Nouman Shafique Safdar Raza Sumayya Bibi Muhammad Farhan Mughees Riaz |
author_sort | Nouman Shafique |
collection | DOAJ |
description | Distributed energy resources (DER’s) incorporation in power system brings economical, technical and environmental benefits. Besides these benefits, excess penetration of DER’s elevates technical concerns. Islanding detection is one of main issue and is essential for personnel safety and protection of equipment. This work introduces a passive islanding detection scheme based on phase angle of positive sequence voltage (PAOPSV). The PAOPSV was selected on the basis of rigorous investigation of 13 different indices. Comparative analysis demonstrates that PAOPSV has the best sensitivity and accuracy for islanding detection among all other parameters. An extensive case study considering worst-case scenarios is accomplished in order to check the working efficacy of the suggested scheme that easily discriminates islanding events from non-islanding events such as load switching, different fault types switching, capacitor and motor switching. The suggested scheme is simple with fast execution and easy to implement that is established on IEEE 1547 generic test system in MATLAB/SIMULINK environment. Islanding is detected within 0.10 s even with a zero non-detection zone. |
first_indexed | 2024-04-14T03:11:18Z |
format | Article |
id | doaj.art-1445d919532a421488e53f53435d0bec |
institution | Directory Open Access Journal |
issn | 2090-4479 |
language | English |
last_indexed | 2024-04-14T03:11:18Z |
publishDate | 2022-06-01 |
publisher | Elsevier |
record_format | Article |
series | Ain Shams Engineering Journal |
spelling | doaj.art-1445d919532a421488e53f53435d0bec2022-12-22T02:15:35ZengElsevierAin Shams Engineering Journal2090-44792022-06-01134101637A simplified passive islanding detection technique based on susceptible power indice with zero NDZNouman Shafique0Safdar Raza1Sumayya Bibi2Muhammad Farhan3Mughees Riaz4Department of Electrical Engineering, NFC Institute of Engineering and Technology, Multan, Pakistan; Corresponding authors.Department of Electrical Engineering, NFC Institute of Engineering and Technology, Multan, Pakistan; Corresponding authors.Department of Electrical Engineering, Bahauddin Zakariya University, Multan, PakistanDepartment of Electrical Engineering & Technology, Government College University, Faisalabad, PakistanDepartment of Electrical Engineering, NFC Institute of Engineering and Technology, Multan, PakistanDistributed energy resources (DER’s) incorporation in power system brings economical, technical and environmental benefits. Besides these benefits, excess penetration of DER’s elevates technical concerns. Islanding detection is one of main issue and is essential for personnel safety and protection of equipment. This work introduces a passive islanding detection scheme based on phase angle of positive sequence voltage (PAOPSV). The PAOPSV was selected on the basis of rigorous investigation of 13 different indices. Comparative analysis demonstrates that PAOPSV has the best sensitivity and accuracy for islanding detection among all other parameters. An extensive case study considering worst-case scenarios is accomplished in order to check the working efficacy of the suggested scheme that easily discriminates islanding events from non-islanding events such as load switching, different fault types switching, capacitor and motor switching. The suggested scheme is simple with fast execution and easy to implement that is established on IEEE 1547 generic test system in MATLAB/SIMULINK environment. Islanding is detected within 0.10 s even with a zero non-detection zone.http://www.sciencedirect.com/science/article/pii/S2090447921004135IslandingDistributed energy resources (DER’s)Phase angle of positive sequence voltage (PAOPSV)Non-detection zone (NDZ)Passive indices |
spellingShingle | Nouman Shafique Safdar Raza Sumayya Bibi Muhammad Farhan Mughees Riaz A simplified passive islanding detection technique based on susceptible power indice with zero NDZ Ain Shams Engineering Journal Islanding Distributed energy resources (DER’s) Phase angle of positive sequence voltage (PAOPSV) Non-detection zone (NDZ) Passive indices |
title | A simplified passive islanding detection technique based on susceptible power indice with zero NDZ |
title_full | A simplified passive islanding detection technique based on susceptible power indice with zero NDZ |
title_fullStr | A simplified passive islanding detection technique based on susceptible power indice with zero NDZ |
title_full_unstemmed | A simplified passive islanding detection technique based on susceptible power indice with zero NDZ |
title_short | A simplified passive islanding detection technique based on susceptible power indice with zero NDZ |
title_sort | simplified passive islanding detection technique based on susceptible power indice with zero ndz |
topic | Islanding Distributed energy resources (DER’s) Phase angle of positive sequence voltage (PAOPSV) Non-detection zone (NDZ) Passive indices |
url | http://www.sciencedirect.com/science/article/pii/S2090447921004135 |
work_keys_str_mv | AT noumanshafique asimplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT safdarraza asimplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT sumayyabibi asimplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT muhammadfarhan asimplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT mugheesriaz asimplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT noumanshafique simplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT safdarraza simplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT sumayyabibi simplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT muhammadfarhan simplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz AT mugheesriaz simplifiedpassiveislandingdetectiontechniquebasedonsusceptiblepowerindicewithzerondz |