Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device
The aim of this paper is to analyze in depth the coupling between leakage electromagnetic fields (EMFs) generated by an electric vehicle wireless power transfer (EV-WPT) device under misaligned operating conditions and metallic coronary stents, which could be potentially hazardous to human electroma...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-10-01
|
Series: | Electronics |
Subjects: | |
Online Access: | https://www.mdpi.com/2079-9292/12/20/4231 |
_version_ | 1797574015955501056 |
---|---|
author | Tianhao Wang Bo Li Kaifeng Zhao Quanyi Yu Linlin Xu Yaodan Chi Shanshan Guan |
author_facet | Tianhao Wang Bo Li Kaifeng Zhao Quanyi Yu Linlin Xu Yaodan Chi Shanshan Guan |
author_sort | Tianhao Wang |
collection | DOAJ |
description | The aim of this paper is to analyze in depth the coupling between leakage electromagnetic fields (EMFs) generated by an electric vehicle wireless power transfer (EV-WPT) device under misaligned operating conditions and metallic coronary stents, which could be potentially hazardous to human electromagnetic safety. In this paper, we established that a standing human with a coronary stent implant and a sitting human with a coronary stent implant are exposed to the leaked EMFs of an EV-WPT device with a transmission power of 11 kW and 22 kW and a transmission frequency of 85 kHz, and we quantified the induced <i>E</i>-field strength of the human body by considering the <i>x</i>- and <i>z</i>-axis misalignment ranges of the WPT device as [−75 mm, 75 mm]. The results showed that the enhancement of the induced <i>E</i>-field in the human tissues near the sharp edges of the implant is significant. Meanwhile, the larger the WPT device misalignment generated, the higher the transmission power, and the closer the human body is to the WPT device, the larger the induced <i>E</i>-field<sub>max</sub> value of the human body is, which has the possibility of exceeding the ICNIRP safety limit, and there is a potential human body electromagnetic safety problem. |
first_indexed | 2024-03-10T21:17:14Z |
format | Article |
id | doaj.art-14f3faeb09da45a9ba5b8fa9f256d828 |
institution | Directory Open Access Journal |
issn | 2079-9292 |
language | English |
last_indexed | 2024-03-10T21:17:14Z |
publishDate | 2023-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Electronics |
spelling | doaj.art-14f3faeb09da45a9ba5b8fa9f256d8282023-11-19T16:18:42ZengMDPI AGElectronics2079-92922023-10-011220423110.3390/electronics12204231Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer DeviceTianhao Wang0Bo Li1Kaifeng Zhao2Quanyi Yu3Linlin Xu4Yaodan Chi5Shanshan Guan6The College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, ChinaThe College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, ChinaThe College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, ChinaThe College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, ChinaThe College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, ChinaJilin Provincial Key Laboratory of Architectural Electricity and Comprehensive Energy Saving, Jilin Jianzhu University, Changchun 130118, ChinaThe College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, ChinaThe aim of this paper is to analyze in depth the coupling between leakage electromagnetic fields (EMFs) generated by an electric vehicle wireless power transfer (EV-WPT) device under misaligned operating conditions and metallic coronary stents, which could be potentially hazardous to human electromagnetic safety. In this paper, we established that a standing human with a coronary stent implant and a sitting human with a coronary stent implant are exposed to the leaked EMFs of an EV-WPT device with a transmission power of 11 kW and 22 kW and a transmission frequency of 85 kHz, and we quantified the induced <i>E</i>-field strength of the human body by considering the <i>x</i>- and <i>z</i>-axis misalignment ranges of the WPT device as [−75 mm, 75 mm]. The results showed that the enhancement of the induced <i>E</i>-field in the human tissues near the sharp edges of the implant is significant. Meanwhile, the larger the WPT device misalignment generated, the higher the transmission power, and the closer the human body is to the WPT device, the larger the induced <i>E</i>-field<sub>max</sub> value of the human body is, which has the possibility of exceeding the ICNIRP safety limit, and there is a potential human body electromagnetic safety problem.https://www.mdpi.com/2079-9292/12/20/4231electric vehicle (EV)wireless power transfer (WPT)precision medical implantsinduced electric field strengthelectromagnetic field exposure |
spellingShingle | Tianhao Wang Bo Li Kaifeng Zhao Quanyi Yu Linlin Xu Yaodan Chi Shanshan Guan Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device Electronics electric vehicle (EV) wireless power transfer (WPT) precision medical implants induced electric field strength electromagnetic field exposure |
title | Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device |
title_full | Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device |
title_fullStr | Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device |
title_full_unstemmed | Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device |
title_short | Evaluation of Electromagnetic Exposure of the Human with a Coronary Stent Implant from an Electric Vehicle Wireless Power Transfer Device |
title_sort | evaluation of electromagnetic exposure of the human with a coronary stent implant from an electric vehicle wireless power transfer device |
topic | electric vehicle (EV) wireless power transfer (WPT) precision medical implants induced electric field strength electromagnetic field exposure |
url | https://www.mdpi.com/2079-9292/12/20/4231 |
work_keys_str_mv | AT tianhaowang evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice AT boli evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice AT kaifengzhao evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice AT quanyiyu evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice AT linlinxu evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice AT yaodanchi evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice AT shanshanguan evaluationofelectromagneticexposureofthehumanwithacoronarystentimplantfromanelectricvehiclewirelesspowertransferdevice |