System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources

Purpose. Increasing the level of safety and reducing the cost of rolling stock maintenance is an urgent problem for Ukrainian railways today. Existing test benches for auxiliary machines are usually built according to the scheme with direct loading of the tested electric machine and do not meet mode...

Full description

Bibliographic Details
Main Author: O. S. Shapovalov
Format: Article
Language:English
Published: Dnipro National University of Railway Transport named after Academician V. Lazaryan 2023-09-01
Series:Nauka ta progres transportu
Subjects:
Online Access:http://stp.diit.edu.ua/article/view/292717
_version_ 1797352339168821248
author O. S. Shapovalov
author_facet O. S. Shapovalov
author_sort O. S. Shapovalov
collection DOAJ
description Purpose. Increasing the level of safety and reducing the cost of rolling stock maintenance is an urgent problem for Ukrainian railways today. Existing test benches for auxiliary machines are usually built according to the scheme with direct loading of the tested electric machine and do not meet modern requirements for the quality and energy efficiency of testing. In this regard, there is a need to design energy-efficient test benches for testing auxiliary machines of electric rolling stock. Methodology. To achieve this goal, we used an analytical method of research to determine the optimal structure of the test bench. The paper considers the voltage balance diagram in the mutual load system. Separately, the calculations are presented, on the basis of which the design diagrams of the electrical and mechanical parts of the test bench are constructed, and the conditions for covering all losses in the mutual load system are determined using the design diagrams. Findings. In the course of the research, the power balance equation in the mutual load system was obtained. On the basis of the equations, a model of a mutual load system with coverage of all losses from a single source of mechanical power was built. The main advantage of the developed model is that it can be implemented both by numerical calculations using composite systems of equations and by object-oriented programming in specialized software systems. Originality. A rational scheme for testing auxiliary machines with the coverage of losses from a single source of mechanical power is proposed. The use of a single power source can significantly reduce the additional consumption of electrical energy due to the more efficient use of auxiliary equipment, in particular, a mechanical power source. Practical value. Based on the results obtained, it is possible to determine the parameters of the scheme for testing auxiliary machines at the design stage of the test bench. Implementation of the research results at auxiliary machine repair enterprises will reduce electricity consumption for post-repair testing due to the higher energy efficiency of the test scheme.
first_indexed 2024-03-08T13:14:01Z
format Article
id doaj.art-15447a9c5bb747749e88a1dc352c122b
institution Directory Open Access Journal
issn 2307-3489
2307-6666
language English
last_indexed 2024-03-08T13:14:01Z
publishDate 2023-09-01
publisher Dnipro National University of Railway Transport named after Academician V. Lazaryan
record_format Article
series Nauka ta progres transportu
spelling doaj.art-15447a9c5bb747749e88a1dc352c122b2024-01-18T10:08:45ZengDnipro National University of Railway Transport named after Academician V. LazaryanNauka ta progres transportu2307-34892307-66662023-09-013(103)243010.15802/stp2023/292717331006System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sourcesO. S. Shapovalov0https://orcid.org/0000-0002-3151-6574Ukrainian State University of Science and TechnologiesPurpose. Increasing the level of safety and reducing the cost of rolling stock maintenance is an urgent problem for Ukrainian railways today. Existing test benches for auxiliary machines are usually built according to the scheme with direct loading of the tested electric machine and do not meet modern requirements for the quality and energy efficiency of testing. In this regard, there is a need to design energy-efficient test benches for testing auxiliary machines of electric rolling stock. Methodology. To achieve this goal, we used an analytical method of research to determine the optimal structure of the test bench. The paper considers the voltage balance diagram in the mutual load system. Separately, the calculations are presented, on the basis of which the design diagrams of the electrical and mechanical parts of the test bench are constructed, and the conditions for covering all losses in the mutual load system are determined using the design diagrams. Findings. In the course of the research, the power balance equation in the mutual load system was obtained. On the basis of the equations, a model of a mutual load system with coverage of all losses from a single source of mechanical power was built. The main advantage of the developed model is that it can be implemented both by numerical calculations using composite systems of equations and by object-oriented programming in specialized software systems. Originality. A rational scheme for testing auxiliary machines with the coverage of losses from a single source of mechanical power is proposed. The use of a single power source can significantly reduce the additional consumption of electrical energy due to the more efficient use of auxiliary equipment, in particular, a mechanical power source. Practical value. Based on the results obtained, it is possible to determine the parameters of the scheme for testing auxiliary machines at the design stage of the test bench. Implementation of the research results at auxiliary machine repair enterprises will reduce electricity consumption for post-repair testing due to the higher energy efficiency of the test scheme.http://stp.diit.edu.ua/article/view/292717testingmutual loadauxiliary machinessubstitution schemeenergy efficiencymathematical model
spellingShingle O. S. Shapovalov
System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
Nauka ta progres transportu
testing
mutual load
auxiliary machines
substitution scheme
energy efficiency
mathematical model
title System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
title_full System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
title_fullStr System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
title_full_unstemmed System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
title_short System of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
title_sort system of mutual loading of auxiliary electric machines with coverage of losses from mechanical power sources
topic testing
mutual load
auxiliary machines
substitution scheme
energy efficiency
mathematical model
url http://stp.diit.edu.ua/article/view/292717
work_keys_str_mv AT osshapovalov systemofmutualloadingofauxiliaryelectricmachineswithcoverageoflossesfrommechanicalpowersources