Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison
<h4>Introduction</h4> Acetabular fractures pose high demands on the surgeon and in the case of osteosynthetic treatment, anatomical reconstruction has the highest priority to achieve a good outcome. However, especially in older patients with poor bone quality, even anatomical reconstruct...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2022-01-01
|
Series: | PLoS ONE |
Online Access: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328528/?tool=EBI |
_version_ | 1811222095473934336 |
---|---|
author | Andreas Höch Rebekka Reise Philipp Pieroh Christoph-Eckhard Heyde Johannes Karl Maria Fakler Stefan Schleifenbaum |
author_facet | Andreas Höch Rebekka Reise Philipp Pieroh Christoph-Eckhard Heyde Johannes Karl Maria Fakler Stefan Schleifenbaum |
author_sort | Andreas Höch |
collection | DOAJ |
description | <h4>Introduction</h4> Acetabular fractures pose high demands on the surgeon and in the case of osteosynthetic treatment, anatomical reconstruction has the highest priority to achieve a good outcome. However, especially in older patients with poor bone quality, even anatomical reconstruction is no guarantee for a good clinical outcome and may nevertheless end in early osteoarthritis. Primary arthroplasty therefore has an increasing importance in the treatment of these patients. The aim of this study was to biomechanically compare fracture gap displacement and failure load as an assessment measure of the primary stability of conventional plate osteosynthesis with the treatment using a sole multi-hole cup for acetabular fractures. <h4>Methods</h4> Six hemi-pelvises each with anterior column and posterior hemi-transverse (ACPHT) fracture were treated with either plate osteosynthesis or a multi-hole cup. The tests were carried out in a standardised test set-up with cyclic loading in various stages between 150 N and 2500 N. The fracture gap displacement was recorded with optical 3D measuring and the failure load was determined after the cyclic measurement. <h4>Results</h4> With increasing force, the fracture gap displacement increased in both procedures. In each group there was one treatment which failed at the cyclic loading test and a bone fragment was broken out. The primary stability in arthroplasty was comparable to that of the standard osteosynthesis. <h4>Conclusions</h4> The results found seem promising that the primary arthroplasty with a sole multi-hole cup and corresponding screw fixation achieves an initial stability comparable to osteosynthesis for typical ACPHT fractures. However, further clinical studies are needed to prove that the cups heal solidly into the bone. |
first_indexed | 2024-04-12T08:10:49Z |
format | Article |
id | doaj.art-156e0f7c448f4e40a5d7923199e4f7d5 |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-04-12T08:10:49Z |
publishDate | 2022-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-156e0f7c448f4e40a5d7923199e4f7d52022-12-22T03:40:57ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01177Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparisonAndreas HöchRebekka ReisePhilipp PierohChristoph-Eckhard HeydeJohannes Karl Maria FaklerStefan Schleifenbaum<h4>Introduction</h4> Acetabular fractures pose high demands on the surgeon and in the case of osteosynthetic treatment, anatomical reconstruction has the highest priority to achieve a good outcome. However, especially in older patients with poor bone quality, even anatomical reconstruction is no guarantee for a good clinical outcome and may nevertheless end in early osteoarthritis. Primary arthroplasty therefore has an increasing importance in the treatment of these patients. The aim of this study was to biomechanically compare fracture gap displacement and failure load as an assessment measure of the primary stability of conventional plate osteosynthesis with the treatment using a sole multi-hole cup for acetabular fractures. <h4>Methods</h4> Six hemi-pelvises each with anterior column and posterior hemi-transverse (ACPHT) fracture were treated with either plate osteosynthesis or a multi-hole cup. The tests were carried out in a standardised test set-up with cyclic loading in various stages between 150 N and 2500 N. The fracture gap displacement was recorded with optical 3D measuring and the failure load was determined after the cyclic measurement. <h4>Results</h4> With increasing force, the fracture gap displacement increased in both procedures. In each group there was one treatment which failed at the cyclic loading test and a bone fragment was broken out. The primary stability in arthroplasty was comparable to that of the standard osteosynthesis. <h4>Conclusions</h4> The results found seem promising that the primary arthroplasty with a sole multi-hole cup and corresponding screw fixation achieves an initial stability comparable to osteosynthesis for typical ACPHT fractures. However, further clinical studies are needed to prove that the cups heal solidly into the bone.https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328528/?tool=EBI |
spellingShingle | Andreas Höch Rebekka Reise Philipp Pieroh Christoph-Eckhard Heyde Johannes Karl Maria Fakler Stefan Schleifenbaum Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison PLoS ONE |
title | Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison |
title_full | Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison |
title_fullStr | Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison |
title_full_unstemmed | Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison |
title_short | Primary stability of multi-hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi-transverse acetabular fractures—A biomechanical comparison |
title_sort | primary stability of multi hole cups compared to plate osteosynthesis in osteoporotic anterior column and posterior hemi transverse acetabular fractures a biomechanical comparison |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328528/?tool=EBI |
work_keys_str_mv | AT andreashoch primarystabilityofmultiholecupscomparedtoplateosteosynthesisinosteoporoticanteriorcolumnandposteriorhemitransverseacetabularfracturesabiomechanicalcomparison AT rebekkareise primarystabilityofmultiholecupscomparedtoplateosteosynthesisinosteoporoticanteriorcolumnandposteriorhemitransverseacetabularfracturesabiomechanicalcomparison AT philipppieroh primarystabilityofmultiholecupscomparedtoplateosteosynthesisinosteoporoticanteriorcolumnandposteriorhemitransverseacetabularfracturesabiomechanicalcomparison AT christopheckhardheyde primarystabilityofmultiholecupscomparedtoplateosteosynthesisinosteoporoticanteriorcolumnandposteriorhemitransverseacetabularfracturesabiomechanicalcomparison AT johanneskarlmariafakler primarystabilityofmultiholecupscomparedtoplateosteosynthesisinosteoporoticanteriorcolumnandposteriorhemitransverseacetabularfracturesabiomechanicalcomparison AT stefanschleifenbaum primarystabilityofmultiholecupscomparedtoplateosteosynthesisinosteoporoticanteriorcolumnandposteriorhemitransverseacetabularfracturesabiomechanicalcomparison |