An experimental study of rotational pressure loss in rotor-stator gap

The annular gap between rotor and stator is an inevitable flow path of a throughflow ventilated electrical machine, but the flow entering the rotor-stator gap is subjected to the effects of rotation. The pressure loss and volumetric flow rate across the rotor-stator gap were measured and compared be...

ver descrição completa

Detalhes bibliográficos
Main Authors: Yew Chuan Chong, Dave A. Staton, Markus A. Mueller, John Chick
Formato: Artigo
Idioma:English
Publicado em: KeAi Communications Co., Ltd. 2017-06-01
Colecção:Propulsion and Power Research
Assuntos:
Acesso em linha:http://www.sciencedirect.com/science/article/pii/S2212540X17300263