Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients

Introduction. Monitoring of redox potential (platinum electrode open circuit potential) in biological media (serum, blood plasma) is one of the promising methods for diagnosing and predicting the development of complications in patients in the early post-transplantation period. The study of the diag...

Full description

Bibliographic Details
Main Authors: A. K. Evseev, E. I. Pervakova, I. V. Goroncharovskaya, E. A. Tarabrin, M. Sh. Khubutiya, M. M. Goldin
Format: Article
Language:English
Published: N.V. Sklifosovsky Research Institute for Emergency Medicine of Moscow Healthcare Department 2019-06-01
Series:Трансплантология (Москва)
Subjects:
Online Access:https://www.jtransplantologiya.ru/jour/article/view/429
_version_ 1797702952601780224
author A. K. Evseev
E. I. Pervakova
I. V. Goroncharovskaya
E. A. Tarabrin
M. Sh. Khubutiya
M. M. Goldin
author_facet A. K. Evseev
E. I. Pervakova
I. V. Goroncharovskaya
E. A. Tarabrin
M. Sh. Khubutiya
M. M. Goldin
author_sort A. K. Evseev
collection DOAJ
description Introduction. Monitoring of redox potential (platinum electrode open circuit potential) in biological media (serum, blood plasma) is one of the promising methods for diagnosing and predicting the development of complications in patients in the early post-transplantation period. The study of the diagnostic capabilities of this technique in patients after lung transplantation is highly relevant.The objective was to assess the diagnostic and prognostic capabilities of monitoring platinum electrode open circuit potential in blood plasma of lung transplant patients.Material and methods. The data obtained at monitoring of platinum electrode open circuit potential in blood plasma and clinical laboratory test results of 14 patients after double lung transplantation surgery were analyzed. The platinum electrode open circuit potential value in the blood plasma was measured by the potentiometric method.Results. The study demonstrated the differences in the dynamics and values of platinum electrode open circuit potential in the blood plasma between the lung transplant patients with a favorable outcome and those with a fatal outcome. Wave-like segments on the relationship curves of the platinum electrode open circuit potential in blood plasma to time coincided with inflammatory markers (C-reactive protein, stab neutrophils, erythrocyte sedimentation rate) activation. Statistically significant correlations between platinum electrode open circuit potential values in blood plasma and clinical laboratory test results were revealed.Conclusion. The informative value and diagnostic capabilities of the technique of the platinum electrode open circuit potential measurement in blood plasma of lung transplant patients have prospects of using its results as a criterion for assessing the patient’s condition and improving the quality of therapy.
first_indexed 2024-03-12T04:57:24Z
format Article
id doaj.art-1591fabc04a14eec9d607672b575e80b
institution Directory Open Access Journal
issn 2074-0506
2542-0909
language English
last_indexed 2024-03-12T04:57:24Z
publishDate 2019-06-01
publisher N.V. Sklifosovsky Research Institute for Emergency Medicine of Moscow Healthcare Department
record_format Article
series Трансплантология (Москва)
spelling doaj.art-1591fabc04a14eec9d607672b575e80b2023-09-03T09:14:39ZengN.V. Sklifosovsky Research Institute for Emergency Medicine of Moscow Healthcare DepartmentТрансплантология (Москва)2074-05062542-09092019-06-0111212814010.23873/2074-0506-2019-11-2-128-140407Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patientsA. K. Evseev0E. I. Pervakova1I. V. Goroncharovskaya2E. A. Tarabrin3M. Sh. Khubutiya4M. M. Goldin5ГБУЗ «НИИ скорой помощи им. Н.В. Склифосовского ДЗМ»ГБУЗ «НИИ скорой помощи им. Н.В. Склифосовского ДЗМ»ГБУЗ «НИИ скорой помощи им. Н.В. Склифосовского ДЗМ»ГБУЗ «НИИ скорой помощи им. Н.В. Склифосовского ДЗМ»ГБУЗ «НИИ скорой помощи им. Н.В. Склифосовского ДЗМ»Колледж Глен Окс КоммьюнитиIntroduction. Monitoring of redox potential (platinum electrode open circuit potential) in biological media (serum, blood plasma) is one of the promising methods for diagnosing and predicting the development of complications in patients in the early post-transplantation period. The study of the diagnostic capabilities of this technique in patients after lung transplantation is highly relevant.The objective was to assess the diagnostic and prognostic capabilities of monitoring platinum electrode open circuit potential in blood plasma of lung transplant patients.Material and methods. The data obtained at monitoring of platinum electrode open circuit potential in blood plasma and clinical laboratory test results of 14 patients after double lung transplantation surgery were analyzed. The platinum electrode open circuit potential value in the blood plasma was measured by the potentiometric method.Results. The study demonstrated the differences in the dynamics and values of platinum electrode open circuit potential in the blood plasma between the lung transplant patients with a favorable outcome and those with a fatal outcome. Wave-like segments on the relationship curves of the platinum electrode open circuit potential in blood plasma to time coincided with inflammatory markers (C-reactive protein, stab neutrophils, erythrocyte sedimentation rate) activation. Statistically significant correlations between platinum electrode open circuit potential values in blood plasma and clinical laboratory test results were revealed.Conclusion. The informative value and diagnostic capabilities of the technique of the platinum electrode open circuit potential measurement in blood plasma of lung transplant patients have prospects of using its results as a criterion for assessing the patient’s condition and improving the quality of therapy.https://www.jtransplantologiya.ru/jour/article/view/429трансплантация легкихпотенциал при разомкнутой цепиплатиновый электродплазма кровивоспалительный процессосложнение
spellingShingle A. K. Evseev
E. I. Pervakova
I. V. Goroncharovskaya
E. A. Tarabrin
M. Sh. Khubutiya
M. M. Goldin
Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
Трансплантология (Москва)
трансплантация легких
потенциал при разомкнутой цепи
платиновый электрод
плазма крови
воспалительный процесс
осложнение
title Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
title_full Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
title_fullStr Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
title_full_unstemmed Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
title_short Diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
title_sort diagnostic capabilities of monitoring of redox potential in blood plasma of lung transplant patients
topic трансплантация легких
потенциал при разомкнутой цепи
платиновый электрод
плазма крови
воспалительный процесс
осложнение
url https://www.jtransplantologiya.ru/jour/article/view/429
work_keys_str_mv AT akevseev diagnosticcapabilitiesofmonitoringofredoxpotentialinbloodplasmaoflungtransplantpatients
AT eipervakova diagnosticcapabilitiesofmonitoringofredoxpotentialinbloodplasmaoflungtransplantpatients
AT ivgoroncharovskaya diagnosticcapabilitiesofmonitoringofredoxpotentialinbloodplasmaoflungtransplantpatients
AT eatarabrin diagnosticcapabilitiesofmonitoringofredoxpotentialinbloodplasmaoflungtransplantpatients
AT mshkhubutiya diagnosticcapabilitiesofmonitoringofredoxpotentialinbloodplasmaoflungtransplantpatients
AT mmgoldin diagnosticcapabilitiesofmonitoringofredoxpotentialinbloodplasmaoflungtransplantpatients